Simulation Dosimetry Studies for FLASH Radiation Therapy (RT) with Ultra-High Dose Rate (UHDR) Electron Beam

被引:1
|
作者
Gazis, Nick [1 ,2 ]
Bignami, Andrea [1 ,2 ]
Trachanas, Emmanouil [1 ,2 ]
Moniaki, Melina [3 ]
Gazis, Evangelos [1 ,3 ]
Bandekas, Dimitrios [4 ]
Vordos, Nikolaos [4 ]
机构
[1] Inst Accelerating Syst & Applicat IASA, Athens 10024, Greece
[2] European Spallat Source ESS ERIC, POB 176, SE-22100 Lund, Sweden
[3] Natl Tech Univ Athens NTUA, Phys Dept, Zografou Campus, Athens 15780, Greece
[4] Democritus Univ Thrace DUTH, Phys Dept, St Lucas 65404, Greece
关键词
FLASH-RT; dosimetry; UHDR; PDD; ASTRA/FLUKA simulations;
D O I
10.3390/qubs8020013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
FLASH-radiotherapy (RT) presents great potential as an alternative to conventional radiotherapy methods in cancer treatment. In this paper, we focus on simulation studies for a linear particle accelerator injector design using the ASTRA code, which permits beam generation and particle tracking through electromagnetic fields. Space charge-dominated beams were selected with the aim of providing an optimized generated beam profile and accelerator lattice with minimized emittance. The main results of the electron beam and ultra-high dose rate (UHDR) simulation dosimetry studies are reported for the FLASH mode radiobiological treatment. Results for the percentage depth dose (PDD) at electron beam energies of 5, 7, 15, 25, 50, 100 MeV and 1.2 GeV for Poly-methyl-methacrylate (PMMA) and water phantom vs. the penetration depth are presented. Additionally, the PDD transverse profile was simulated for the above energies, delivering the beam to the phantom. The simulation dosimetry results provide an UHDR electron beam under the conditions of the FLASH-RT. The performance of the beam inside the phantom and the dose depth depends on the linear accelerator beam's energy and stability.
引用
收藏
页数:15
相关论文
共 43 条
  • [41] Proton Bragg Peak FLASH Enables Organ Sparing and Ultra-High Dose-Rate Delivery: Proof of Principle in Recurrent Head and Neck Cancer
    Pennock, Michael
    Wei, Shouyi
    Cheng, Chingyun
    Lin, Haibo
    Hasan, Shaakir
    Chhabra, Arpit M.
    Choi, J. Isabelle
    Bakst, Richard L.
    Kabarriti, Rafi
    Simone II, Charles B.
    Lee, Nancy Y. Y.
    Kang, Minglei
    Press, Robert H.
    CANCERS, 2023, 15 (15)
  • [43] Dosimetry analyses comparing high-dose-rate brachytherapy, administered as monotherapy for localized prostate cancer, with stereotactic body radiation therapy simulated using CyberKnife
    Fukuda, Shoichi
    Seo, Yuji
    Shiomi, Hiroya
    Yamada, Yuji
    Ogata, Toshiyuki
    Morimoto, Masahiro
    Konishi, Koji
    Yoshioka, Yasuo
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1114 - 1121