Simulation Dosimetry Studies for FLASH Radiation Therapy (RT) with Ultra-High Dose Rate (UHDR) Electron Beam

被引:1
|
作者
Gazis, Nick [1 ,2 ]
Bignami, Andrea [1 ,2 ]
Trachanas, Emmanouil [1 ,2 ]
Moniaki, Melina [3 ]
Gazis, Evangelos [1 ,3 ]
Bandekas, Dimitrios [4 ]
Vordos, Nikolaos [4 ]
机构
[1] Inst Accelerating Syst & Applicat IASA, Athens 10024, Greece
[2] European Spallat Source ESS ERIC, POB 176, SE-22100 Lund, Sweden
[3] Natl Tech Univ Athens NTUA, Phys Dept, Zografou Campus, Athens 15780, Greece
[4] Democritus Univ Thrace DUTH, Phys Dept, St Lucas 65404, Greece
关键词
FLASH-RT; dosimetry; UHDR; PDD; ASTRA/FLUKA simulations;
D O I
10.3390/qubs8020013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
FLASH-radiotherapy (RT) presents great potential as an alternative to conventional radiotherapy methods in cancer treatment. In this paper, we focus on simulation studies for a linear particle accelerator injector design using the ASTRA code, which permits beam generation and particle tracking through electromagnetic fields. Space charge-dominated beams were selected with the aim of providing an optimized generated beam profile and accelerator lattice with minimized emittance. The main results of the electron beam and ultra-high dose rate (UHDR) simulation dosimetry studies are reported for the FLASH mode radiobiological treatment. Results for the percentage depth dose (PDD) at electron beam energies of 5, 7, 15, 25, 50, 100 MeV and 1.2 GeV for Poly-methyl-methacrylate (PMMA) and water phantom vs. the penetration depth are presented. Additionally, the PDD transverse profile was simulated for the above energies, delivering the beam to the phantom. The simulation dosimetry results provide an UHDR electron beam under the conditions of the FLASH-RT. The performance of the beam inside the phantom and the dose depth depends on the linear accelerator beam's energy and stability.
引用
收藏
页数:15
相关论文
共 43 条
  • [21] Investigation of TL and OSL detectors in ultra-high dose rate electron beams
    Motta, S.
    Christensen, J. B.
    Frei, F.
    Peier, P.
    Yukihara, E. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14)
  • [22] Characterisation of the UK high energy proton research beamline for high and ultra-high dose rate (FLASH) irradiation
    Aylward, J. D.
    Henthorn, N.
    Manger, S.
    Warmenhoven, J. W.
    Merchant, M. J.
    Taylor, M. J.
    Mackay, R., I
    Kirkby, K. J.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (05):
  • [23] Dosimetric calibration of anatomy-specific ultra-high dose rate electron irradiation platform for preclinical FLASH radiobiology experiments
    Wang, Jinghui
    Melemenidis, Stavros
    Manjappa, Rakesh
    Viswanathan, Vignesh
    Ashraf, Ramish M.
    Levy, Karen
    Skinner, Lawrie B.
    Soto, Luis A.
    Chow, Stephanie
    Lau, Brianna
    Ko, Ryan B.
    Graves, Edward E.
    Yu, Amy S.
    Bush, Karl K.
    Surucu, Murat
    Rankin, Erinn B.
    Loo, Billy W.
    Schuler, Emil
    Maxim, Peter G.
    MEDICAL PHYSICS, 2024, 51 (12) : 9166 - 9178
  • [24] Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
    Deut, Umberto
    Camperi, Aurora
    Cavicchi, Cristiano
    Cirio, Roberto
    Data, Emanuele Maria
    Durisi, Elisabetta Alessandra
    Ferrero, Veronica
    Ferro, Arianna
    Giordanengo, Simona
    Villarreal, Oscar Marti
    Mas Milian, Felix
    Medina, Elisabetta
    Olivares, Diango M. Montalvan
    Mostardi, Franco
    Monti, Valeria
    Sacchi, Roberto
    Salmeri, Edoardo
    Vignati, Anna
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [25] Technical note: High-dose and ultra-high dose rate (UHDR) evaluation of Al2O3:C optically stimulated luminescent dosimeter nanoDots and powdered LiF:Mg,Ti thermoluminescent dosimeters for radiation therapy applications
    Liu, Kevin
    Velasquez, Brett
    Schuler, Emil
    MEDICAL PHYSICS, 2024, 51 (03) : 2311 - 2319
  • [26] Time-resolved dosimetry of pulsed electron beams in very high dose-rate, FLASH irradiation for radiotherapy preclinical studies
    Favaudon, Vincent
    Lentz, Jean-Michel
    Heinrich, Sophie
    Patriarca, Annalisa
    de Marzi, Ludovic
    Fouillade, Charles
    Dutreix, Marie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [27] A prototype scintillator real-time beam monitor for ultra-high dose rate radiotherapy
    Levin, Daniel S.
    Friedman, Peter S.
    Ferretti, Claudio
    Ristow, Nicholas
    Tecchio, Monica
    Litzenberg, Dale W.
    Bashkirov, Vladimir
    Schulte, Reinhard
    MEDICAL PHYSICS, 2024, 51 (04) : 2905 - 2923
  • [28] Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments
    Dal Bello, Riccardo
    von der Grun, Jens
    Fabiano, Silvia
    Rudolf, Thomas
    Saltybaeva, Natalia
    Stark, Luisa S.
    Ahmed, Md
    Bathula, Manohar
    Dogan, Serpil Kucuker
    McNeur, Joshua
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    RADIOTHERAPY AND ONCOLOGY, 2023, 187
  • [29] Monte Carlo optimization of a GRID collimator for preclinical megavoltage ultra-high dose rate spatially-fractionated radiation therapy
    Clements, Nathan
    Bazalova-Carter, Magdalena
    Esplen, Nolan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (18)
  • [30] On the potential biological impact of radiation-induced acoustic emissions during ultra-high dose rate electron radiotherapy: a preliminary study
    Lascaud, Julie
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05)