UTILIZING STENT WALL SHEAR STRESS TO ASSESS STENT AND FLOW DIVERTER PERFORMANCE FOR TREATING INTRACRANIAL ANEURYSMS

被引:0
|
作者
Suess, Taylor N. [1 ]
Gent, Stephen P. [1 ]
机构
[1] South Dakota State Univ, Dept Mech Engn, Brookings, SD 57007 USA
来源
PROCEEDINGS OF ASME 2022 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2022, VOL 4 | 2022年
关键词
flow diverter; stent; computational fluid dynamics; CFD; wall shear stress; HEMODYNAMICS; RUPTURE; OCCLUSION; MODEL;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of flow diverting intracranial aneurysm repair devices has traditionally focused on reducing intrasaccular blood flow velocity and aneurysm wall shear stress (WSS) as the primary metrics for improved perceived device performance. However, the interpretation of this data has been debated, particularly with regards to the specific biological benefits of high or low aneurysm WSS. Therefore, this research proposes an additional parameter of WSS at the stent struts that could provide valuable insight regarding the device's potential to promote occlusion at the aneurysm neck by indicating potential locations of increased platelet activation and microparticle shedding. Fluid flow effects were evaluated for two flow diverters (Pipeline (TM) and FRED (TM)) and three stents (Enterprise, Atlas (TM), and LVIS (TM)) using computational fluid dynamics (CFD) models developed from two patient-derived CTA datasets with aneurysms in the middle cerebral artery (MCA) and basilar artery (BA), respectively. The device WSS data provides an additional metric for evaluating the ability of the device to constrain the blood flow within the main vessel, as well as determining the point at which the blood flow is released into the aneurysm, indicating the potential locations of the initiation of aneurysm occlusion. It is hypothesized that high device WSS close to the aneurysm neck creates a higher likelihood of aneurysm occlusion due to platelet activation and microparticle shedding, while high device WSS proximal on the device would indicate higher likelihood of undesirable daughter vessel occlusion. Conversely, low-to-moderate device WSS throughout the device length could be interpreted as less flow diversion and more consistent blood flow allowed into the aneurysm, resulting in lesser device performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] In Vitro Comparison of the Effect of Stent Configuration on Wall Shear Stress Using Time-resolved Particle Image Velocimetry
    Charonko, John
    Karri, Satyaprakash
    Schmieg, Jaime
    Prabhu, Santosh
    Vlachos, Pavlos
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 889 - 902
  • [32] Uncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability
    Sarrami-Foroushani, Ali
    Lassila, Toni
    Gooya, Ali
    Geers, Arjan J.
    Frangi, Alejandro F.
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3815 - 3823
  • [33] Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress
    Benard, N
    Coisne, D
    Donal, E
    Perrault, R
    JOURNAL OF BIOMECHANICS, 2003, 36 (07) : 991 - 998
  • [34] Effects of stent-assisted coiling in comparison with flow diversion on intracranial aneurysms
    Guo, Hao
    Liu, Jian-Feng
    Li, Cong-Hui
    Wang, Ji-Wei
    Li, Hui
    Gao, Bu-Lang
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [35] Stent Design for Compensating Wall Shear Stress via Computational Modeling and Fluid Dynamics
    Chang, Chun-Ming
    Wong, Wei Shin
    Tsai, Jeffrey J. P.
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2016, : 204 - 207
  • [36] Simulation of wall shear stress-driven in-stent restenosis
    De Santis, G.
    Mortier, P.
    De Beule, M.
    Segers, P.
    Verdonck, P.
    Verhegghe, B.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1955 - 1958
  • [37] A study of wall shear stress in 12 aneurysms with respect to different viscosity models and flow conditions
    Evju, Oyvind
    Valen-Sendstad, Kristian
    Mardal, Kent-Andre
    JOURNAL OF BIOMECHANICS, 2013, 46 (16) : 2802 - 2808
  • [38] Efficacy and safety of the dual-layer flow-diverting stent (FRED) for the treatment of intracranial aneurysms
    Guimaraens, Leopoldo
    Vivas, Elio
    Saldana, Jesus
    Llibre, Juan Carlos
    Gil, Alberto
    Balaguer, Ernest
    Rodriguez-Campello, Ana
    Cuadrado-Godia, Elisa
    Ois, Angel
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (05) : 521 - 525
  • [39] Flow diverters versus stent-assisted coiling in unruptured intracranial vertebral artery dissecting aneurysms
    Han, Jiangli
    Tong, Xin
    Han, Mingyang
    Peng, Fei
    Niu, Hao
    Liu, Fei
    Liu, Aihua
    JOURNAL OF NEUROSURGERY, 2023, 140 (04) : 1064 - 1070
  • [40] Wall shear stress in the development of in-stent restenosis revisited. A critical review of clinical data on shear stress after intracoronary stent implantation
    Jenei, Csaba
    Balogh, Emilia
    Szabo, Gabor Tamas
    Dezsi, Csaba Andras
    Koszegi, Zsolt
    CARDIOLOGY JOURNAL, 2016, 23 (04) : 365 - 373