UTILIZING STENT WALL SHEAR STRESS TO ASSESS STENT AND FLOW DIVERTER PERFORMANCE FOR TREATING INTRACRANIAL ANEURYSMS

被引:0
|
作者
Suess, Taylor N. [1 ]
Gent, Stephen P. [1 ]
机构
[1] South Dakota State Univ, Dept Mech Engn, Brookings, SD 57007 USA
来源
PROCEEDINGS OF ASME 2022 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2022, VOL 4 | 2022年
关键词
flow diverter; stent; computational fluid dynamics; CFD; wall shear stress; HEMODYNAMICS; RUPTURE; OCCLUSION; MODEL;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of flow diverting intracranial aneurysm repair devices has traditionally focused on reducing intrasaccular blood flow velocity and aneurysm wall shear stress (WSS) as the primary metrics for improved perceived device performance. However, the interpretation of this data has been debated, particularly with regards to the specific biological benefits of high or low aneurysm WSS. Therefore, this research proposes an additional parameter of WSS at the stent struts that could provide valuable insight regarding the device's potential to promote occlusion at the aneurysm neck by indicating potential locations of increased platelet activation and microparticle shedding. Fluid flow effects were evaluated for two flow diverters (Pipeline (TM) and FRED (TM)) and three stents (Enterprise, Atlas (TM), and LVIS (TM)) using computational fluid dynamics (CFD) models developed from two patient-derived CTA datasets with aneurysms in the middle cerebral artery (MCA) and basilar artery (BA), respectively. The device WSS data provides an additional metric for evaluating the ability of the device to constrain the blood flow within the main vessel, as well as determining the point at which the blood flow is released into the aneurysm, indicating the potential locations of the initiation of aneurysm occlusion. It is hypothesized that high device WSS close to the aneurysm neck creates a higher likelihood of aneurysm occlusion due to platelet activation and microparticle shedding, while high device WSS proximal on the device would indicate higher likelihood of undesirable daughter vessel occlusion. Conversely, low-to-moderate device WSS throughout the device length could be interpreted as less flow diversion and more consistent blood flow allowed into the aneurysm, resulting in lesser device performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Flow-diverter stent to manage intracranial aneurysms: A single center experience
    Feng, Shao-Wei
    Luo, Chao-Bao
    Lee, Chien-Hui
    Chang, Feng-Chi
    Lin, Chung-Jung
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (03) : 358 - 363
  • [2] Mechanical design of an intracranial stent for treating cerebral aneurysms
    Shobayashi, Yasuhiro
    Tanoue, Tetsuya
    Tateshima, Satoshi
    Tanishita, Kazuo
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (09) : 1015 - 1024
  • [3] Morphological Effect on Wall Shear Stress in Intracranial Aneurysms
    Qiu, Tian-Lun
    Jin, Guo-Liang
    Bao, Wu-Qiao
    Lu, Hai-Tao
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2018, 79 (02) : 108 - 115
  • [4] A new flow diverter stent for direct treatment of intracranial aneurysm
    Ma, Jiayao
    You, Zhong
    Peach, Thomas
    Byrne, James
    Rizkallah, Rafik R.
    JOURNAL OF BIOMECHANICS, 2015, 48 (16) : 4206 - 4213
  • [5] Flow instability and wall shear stress variation in intracranial aneurysms
    Baek, H.
    Jayaraman, M. V.
    Richardson, P. D.
    Karniadakis, G. E.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2010, 7 (47) : 967 - 988
  • [6] CFD Study on the Efficacy of Flow Diverter Stent Placement for Cerebral Aneurysms
    Ito, Y.
    Cho, I
    Sakai, Y.
    Iwano, K.
    JOURNAL OF APPLIED FLUID MECHANICS, 2021, 14 (05) : 1547 - 1558
  • [7] Treatment of Intracranial Aneurysms with the FRED X Flow Diverter Stent: Mid-term Angiographic and Safety Results
    Wen, David W.
    Ayre, James
    Puthuran, Mani
    Maliakal, Paul
    Masri, Souhyb
    Pullicino, Richard
    Smith, Aubrey
    Babatola, Feyi
    Gravino, Gilbert
    Abdelsalam, Nasr
    Nejadhamzeeigilani, Hamed
    Chandran, Arun
    CLINICAL NEURORADIOLOGY, 2025,
  • [8] Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment
    Zhang, Y.
    Chong, W.
    Qian, Y.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (05) : 608 - 615
  • [9] Pipeline Flow-Diverter Stent for Endovascular Treatment of Intracranial Aneurysms: Preliminary Experience in 20 Patients with 27 Aneurysms
    Lubicz, Boris
    Collignon, Laurent
    Raphaeli, Gai
    De Witte, Olivier
    WORLD NEUROSURGERY, 2011, 76 (1-2) : 114 - 119
  • [10] Severe in-stent stenosis after intracranial saccular aneurysm treatment with a flow diverter stent
    de Oliveira, Arthur Magalhaes
    Hazzan, Mario Altikes
    da Silveira Filho, Luciano Jose
    Dias, Guilherme Marcos Soares
    de Rezende, Andre Luiz
    de Almeida Silva, Joao Miguel
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2021, 25