Intraocular pressure measurement using ICare rebound tonometer in different positions of eye and different locations on cornea

被引:0
|
作者
Wongwanwatana, Sirada [1 ]
Treesit, Isaraporn [1 ]
Funarunart, Panrapee [1 ]
Iemsomboon, Wallop [1 ]
Choontanom, Raveewan [1 ]
机构
[1] Phramongkutklao Hosp, Dept Ophthalmol, Phramongkutklao Coll Med, 315 Ratchawithi Rd, Bangkok 10400, Thailand
关键词
IC200; iCare rebound tonometer; intraocular pressure; GOLDMANN APPLANATION TONOMETER; AGREEMENT;
D O I
10.1097/MD.0000000000034874
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intraocular pressure (IOP) is one of the most crucial aspects for diagnosis and treatment plan among patients with glaucoma. Although the gold standard for IOP measurement is Goldmann applanation tonometer (GAT)([1]), it must be mounted to a slit lamp biomicroscope. However, rebound tonometer has become popular due to its ease of operation and portable design, does not require topical anesthesia, and results do not differ significantly from those of GAT([2]). The purpose of this cross-sectional study is to investigate the difference in IOP measurement with iCare IC200 in different angles of the eye and different corneal locations. All participants underwent IOP measurement by GAT twice. Then, IOP was measured with iCare by a single physician. IOP was measured in a straight manner in the upright patient position; then participants were asked to look at fixation targets, which located in four different points. IOP was measured in upgaze, downgaze, medial gaze, and lateral gaze. Then, IOP was measured at 2mm from limbus in superior, inferior, nasal, and temporal cornea. All methods were measured twice, and the mean was used for calculation. The physician who measured IOP by iCare was masked from GAT results. A total of 168 eyes were tested with a mean age of 62.15 +/- 12.34 years. Mean IOP measured by GAT and iCare at the central cornea was 15.53 +/- 5.57 and 14.78 +/- 6.14 mmHg, respectively. The standardized mean difference (SMD) between iCare and GAT was 0.13 (-0.09-0.34), which is insignificant. The average IOP was 0.6, 0.47, 0.91, and 0.44 mmHg lower than the primary position in upgaze, downgaze, medial gaze, and lateral gaze 15degrees angulated positions respectively (p<.01). IOPs at 2mm from limbus in the inferior, nasal, and temporal cornea were 0.5, 0.69, and 0.57 mmHg lower than IOP measured at the central cornea (p=<.01). IOP measurements with iCare in different angles of eye were statistically significantly lower than in the primary position. Similarly, IOPs at different locations on cornea were lower than at the central cornea. However, the difference in IOP measurements with iCare in different angles of the eye and different corneal locations was in the trivial range and might be clinically insignificant.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Intraocular Pressure Measurements Using Rebound Tonometry in Eight Different Species of Companion Birds
    Karimi, Vahid
    Asadi, Faezeh
    Rajaei, Seyed Mehdi
    Golabdar, Salar
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2020, 34 (04) : 338 - 342
  • [42] Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL
    Barkana, Yaniv
    Gutfreund, Shay
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) : 608 - 614
  • [43] Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions
    Schweier, Caterina
    Hanson, James V. M.
    Funk, Jens
    Toeteberg-Harms, Marc
    BMC OPHTHALMOLOGY, 2013, 13
  • [44] Comparison of Goldmann Applanation Tonometer, Noncontact Tonometer, and TonoPen XL for Intraocular Pressure Measurement in Different Types of Glaucomatous, Ocular Hypertensive, and Normal Eyes
    Kim, Na Rae
    Kim, Chan Yun
    Kim, Hyunjoong
    Seong, Gong Je
    Lee, Eun Suk
    CURRENT EYE RESEARCH, 2011, 36 (04) : 295 - 300
  • [45] Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer
    Cheng, ACK
    Leung, DYL
    Cheung, EYY
    Fan, DSP
    Law, RWK
    Lam, DSC
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) : 153 - 157
  • [46] Intraocular pressure at different gaze positions in patients with highly myopic strabismus
    Arai, Shinji
    Suzuki, Hiroko
    Hayashi, Shion
    Inagaki, Risako
    Haseoka, Takashi
    Hikoya, Akiko
    Komori, Miwa
    Shimizu, Tamami
    Muhammad, Nazmul Haque
    Hotta, Yoshihiro
    Sato, Miho
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022, 66 (06) : 572 - 578
  • [47] Intraocular pressure at different gaze positions in patients with highly myopic strabismus
    Shinji Arai
    Hiroko Suzuki
    Shion Hayashi
    Risako Inagaki
    Takashi Haseoka
    Akiko Hikoya
    Miwa Komori
    Tamami Shimizu
    Nazmul Haque Muhammad
    Yoshihiro Hotta
    Miho Sato
    Japanese Journal of Ophthalmology, 2022, 66 : 572 - 578
  • [48] ASSESSMENT OF INTRAOCULAR PRESSURE BY APPLANATION AND REBOUND TONOMETRY IN GUINEA PIGS OF DIFFERENT AGES
    Cairo, Marti
    Teresa Pena, Maria
    Rios, Jose
    Melero, Adria
    Martorell, Jaume
    Leiva, Marta
    JOURNAL OF EXOTIC PET MEDICINE, 2018, 27 (01) : 25 - 31
  • [49] Comparison of Intraocular Pressure Measurements Using Three Different Methods (Goldmann Applanation Tonometry (GAT), Corvis ST, and iCare) Following Penetrating Keratoplasty
    Tziola, Tatiana
    Tzamalis, Argyrios
    Koronis, Spyridon
    Garitsis, Panagiotis
    Tsinopoulos, Ioannis
    Ziakas, Nikolaos
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
  • [50] Effect of different surgical positions on intraocular pressure: a cross-sectional study
    Yuhong Sun
    Juan Wang
    Wei Wang
    Guohui Fan
    Sinan Wu
    Fei Zhao
    Yi Lu
    Di Liu
    Yan Li
    Jin Hu
    Lin Yang
    Yu Bai
    Tong Zhao
    Ying Zhao
    BMC Ophthalmology, 22