Intraocular pressure measurement using ICare rebound tonometer in different positions of eye and different locations on cornea

被引:0
|
作者
Wongwanwatana, Sirada [1 ]
Treesit, Isaraporn [1 ]
Funarunart, Panrapee [1 ]
Iemsomboon, Wallop [1 ]
Choontanom, Raveewan [1 ]
机构
[1] Phramongkutklao Hosp, Dept Ophthalmol, Phramongkutklao Coll Med, 315 Ratchawithi Rd, Bangkok 10400, Thailand
关键词
IC200; iCare rebound tonometer; intraocular pressure; GOLDMANN APPLANATION TONOMETER; AGREEMENT;
D O I
10.1097/MD.0000000000034874
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intraocular pressure (IOP) is one of the most crucial aspects for diagnosis and treatment plan among patients with glaucoma. Although the gold standard for IOP measurement is Goldmann applanation tonometer (GAT)([1]), it must be mounted to a slit lamp biomicroscope. However, rebound tonometer has become popular due to its ease of operation and portable design, does not require topical anesthesia, and results do not differ significantly from those of GAT([2]). The purpose of this cross-sectional study is to investigate the difference in IOP measurement with iCare IC200 in different angles of the eye and different corneal locations. All participants underwent IOP measurement by GAT twice. Then, IOP was measured with iCare by a single physician. IOP was measured in a straight manner in the upright patient position; then participants were asked to look at fixation targets, which located in four different points. IOP was measured in upgaze, downgaze, medial gaze, and lateral gaze. Then, IOP was measured at 2mm from limbus in superior, inferior, nasal, and temporal cornea. All methods were measured twice, and the mean was used for calculation. The physician who measured IOP by iCare was masked from GAT results. A total of 168 eyes were tested with a mean age of 62.15 +/- 12.34 years. Mean IOP measured by GAT and iCare at the central cornea was 15.53 +/- 5.57 and 14.78 +/- 6.14 mmHg, respectively. The standardized mean difference (SMD) between iCare and GAT was 0.13 (-0.09-0.34), which is insignificant. The average IOP was 0.6, 0.47, 0.91, and 0.44 mmHg lower than the primary position in upgaze, downgaze, medial gaze, and lateral gaze 15degrees angulated positions respectively (p<.01). IOPs at 2mm from limbus in the inferior, nasal, and temporal cornea were 0.5, 0.69, and 0.57 mmHg lower than IOP measured at the central cornea (p=<.01). IOP measurements with iCare in different angles of eye were statistically significantly lower than in the primary position. Similarly, IOPs at different locations on cornea were lower than at the central cornea. However, the difference in IOP measurements with iCare in different angles of the eye and different corneal locations was in the trivial range and might be clinically insignificant.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Effectiveness of the ICare rebound tonometer in patients with overestimated intraocular pressure due to tight orbit syndrome
    Lee, Y. K.
    Lee, J. Y.
    Moon, J. I.
    Park, M. H.
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (06) : 496 - 502
  • [22] Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects
    Guler, Mete
    Bilak, Semsettin
    Bilgin, Burak
    Simsek, Ali
    Capkin, Musa
    Reyhan, Ali Hakim
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 613 - 618
  • [23] Evaluation of a new rebound tonometer for self-measurement of intraocular pressure
    Dabasia, Priya L.
    Lawrenson, John G.
    Murdoch, Ian E.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) : 1139 - 1143
  • [24] A comparison of intraocular pressure values obtained with the Tono-Pachymeter NT530P iCare (R) rebound tonometer and Goldmann applanation tonometer
    Rampersad, N.
    Mashige, K. P.
    Jhetamt, S.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2011, 70 (03):
  • [25] Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study
    Nacaroglu, Senay Asik
    Un, Emine Seker
    Ersoz, Mehmet Giray
    Tasci, Yelda
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (03) : 540 - 543
  • [26] Comparative study of measurement of intraocular pressure in eyes with corneal opacity and normal cornea by Tonopen Avia, rebound tonometer (I-care), and noncontact tonometer
    Reddy, Sridhara
    Sharma, VijayK
    Moulick, Partha Sarathy
    Singh, Atul Kumar
    JOURNAL OF MARINE MEDICAL SOCIETY, 2020, 22 (02) : 207 - 211
  • [27] The Effect of Yoga on Intraocular Pressure Using the "iCare HOME2" Tonometer
    Shajiei, Tania Darja
    Wachtl, Josephine
    Schuknecht, Angelika
    Bachmann, Lucas
    Kniestedt, Christoph
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (04) : 347 - 354
  • [28] The influence of the tonometer position on canine intraocular pressure measurements using the Tonovet (R) rebound tonometer
    de Oliveira, Juliana Kravetz
    Montiani-Ferreira, Fabiano
    Williams, David L.
    OPEN VETERINARY JOURNAL, 2018, 8 (01) : 68 - 76
  • [29] A comparison of intraocular pressure measurement using SUOER SW-500 rebound tonometer and conventional reusable Goldmann prisms
    Chaung, Jia Quan
    Sangapillai, Thanendthire
    Quilat, Karen Kate
    Perera, Shamira
    FRONTIERS IN MEDICINE, 2024, 11
  • [30] Assessment of intraocular pressure measurement between Goldman applanation tonometer, rebound tonometer, non-contact tonometer, and its correlation with central corneal thickness
    Porwal, Amit C.
    Shrishrimal, Meghna
    Punamia, Ravin P.
    Mathew, Bennet Chacko
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 1927 - 1931