Ultra-low-field magnetization transfer imaging at 0.055T with low specific absorption rate

被引:1
作者
Su, Shi [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Ding, Ye [1 ,2 ]
Lau, Vick [1 ,2 ]
Xiao, Linfang [1 ,2 ]
Leung, Gilberto K. K. [3 ]
Lau, Gary K. K. [4 ]
Huang, Fan [5 ]
Vardhanabhuti, Vince [5 ]
Leong, Alex T. L. [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dept Surg, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Med, Hong Kong, Peoples R China
[5] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Peoples R China
关键词
brain; magnetization transfer; MRI; specific absorption rate; tissue contrast; ultra-low-field; INHOMOGENEOUSLY BROADENED LINES; SPIN-LOCK; MRI; RELAXATION; TISSUE; T-1;
D O I
10.1002/mrm.30231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate magnetization transfer (MT) effects with low specific absorption rate (SAR) on ultra-low-field (ULF) MRI. Methods: MT imaging was implemented by using sinc-modulated RF pulse train (SPT) modules to provide bilateral off-resonance irradiation. They were incorporated into 3D gradient echo (GRE) and fast spin echo (FSE) protocols on a shielding-free 0.055T head scanner. MT effects were first verified using phantoms. Brain MT imaging was conducted in both healthy subjects and patients. Results: MT effects were clearly observed in phantoms using six SPT modules with total flip angle 3600 degrees at central primary saturation bands of approximate offset +/- 786Hz, even in the presence of large relative B-0 inhomogeneity. For brain, strong MT effects were observed in gray matter, white matter, and muscle in 3D GRE and FSE imaging using six and sixteen SPT modules with total flip angle 3600 degrees and 9600 degrees, respectively. Fat, cerebrospinal fluid, and blood exhibited relatively weak MT effects. MT preparation enhanced tissue contrasts in T2-weighted and FLAIR-like images, and improved brain lesion delineation. The estimated MT SAR was 0.0024 and 0.0008W/kg for two protocols, respectively, which is far below the US Food and Drug Administration (FDA) limit of 3.0W/kg. Conclusion: Robust MT effects can be readily obtained at ULF with extremely low SAR, despite poor relative B-0 homogeneity in ppm. This unique advantage enables flexible MT pulse design and implementation on low-cost ULF MRI platforms to achieve strong MT effects in brain and beyond, potentially augmenting their clinical utility in the future.
引用
收藏
页码:2420 / 2432
页数:13
相关论文
共 51 条
[21]   Deep learning enabled fast 3D brain MRI at 0.055 tesla [J].
Man, Christopher ;
Lau, Vick ;
Su, Shi ;
Zhao, Yujiao ;
Xiao, Linfang ;
Ding, Ye ;
Leung, Gilberto K. K. ;
Leong, Alex T. L. ;
Wu, Ed X. .
SCIENCE ADVANCES, 2023, 9 (38)
[22]   Low-field MRI: An MR physics perspective [J].
Marques, Jose P. ;
Simonis, Frank F. J. ;
Webb, Andrew G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (06) :1528-1542
[23]   Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 Tesla [J].
Martirosian, Petros ;
Boss, Andreas ;
Deimling, Michael ;
Kiefer, Berthold ;
Schraml, Christina ;
Schwenzer, Nina F. ;
Claussen, Claus D. ;
Schick, Fritz .
INVESTIGATIVE RADIOLOGY, 2008, 43 (01) :16-26
[24]  
Mazurek MH, 2021, NEUROLOGY, V96
[25]   Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage [J].
Mazurek, Mercy H. ;
Cahn, Bradley A. ;
Yuen, Matthew M. ;
Prabhat, Anjali M. ;
Chavva, Isha R. ;
Shah, Jill T. ;
Crawford, Anna L. ;
Welch, E. Brian ;
Rothberg, Jonathan ;
Sacolick, Laura ;
Poole, Michael ;
Wira, Charles ;
Matouk, Charles C. ;
Ward, Adrienne ;
Timario, Nona ;
Leasure, Audrey ;
Beekman, Rachel ;
Peng, Teng J. ;
Witsch, Jens ;
Antonios, Joseph P. ;
Falcone, Guido J. ;
Gobeske, Kevin T. ;
Petersen, Nils ;
Schindler, Joseph ;
Sansing, Lauren ;
Gilmore, Emily J. ;
Hwang, David Y. ;
Kim, Jennifer A. ;
Malhotra, Ajay ;
Sze, Gordon ;
Rosen, Matthew S. ;
Kimberly, W. Taylor ;
Sheth, Kevin N. .
NATURE COMMUNICATIONS, 2021, 12 (01)
[26]   The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging [J].
McDaniel, Patrick C. ;
Cooley, Clarissa Zimmerman ;
Stockmann, Jason P. ;
Wald, Lawrence L. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (05) :1946-1960
[27]   MAGNETIZATION TRANSFER EFFECTS IN MULTISLICE RARE SEQUENCES [J].
MELKI, PS ;
MULKERN, RV .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (01) :189-195
[28]   NEAR-RESONANCE SPIN-LOCK CONTRAST [J].
MORAN, PR ;
HAMILTON, CA .
MAGNETIC RESONANCE IMAGING, 1995, 13 (06) :837-846
[29]   In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array [J].
O'Reilly, Thomas ;
Teeuwisse, Wouter M. ;
de Gans, Danny ;
Koolstra, Kirsten ;
Webb, Andrew G. .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) :495-505
[30]   The physics of MRI safety [J].
Panych, Lawrence P. ;
Madore, Bruno .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) :28-43