Ultra-low-field magnetization transfer imaging at 0.055T with low specific absorption rate

被引:1
作者
Su, Shi [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Ding, Ye [1 ,2 ]
Lau, Vick [1 ,2 ]
Xiao, Linfang [1 ,2 ]
Leung, Gilberto K. K. [3 ]
Lau, Gary K. K. [4 ]
Huang, Fan [5 ]
Vardhanabhuti, Vince [5 ]
Leong, Alex T. L. [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dept Surg, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Med, Hong Kong, Peoples R China
[5] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Peoples R China
关键词
brain; magnetization transfer; MRI; specific absorption rate; tissue contrast; ultra-low-field; INHOMOGENEOUSLY BROADENED LINES; SPIN-LOCK; MRI; RELAXATION; TISSUE; T-1;
D O I
10.1002/mrm.30231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate magnetization transfer (MT) effects with low specific absorption rate (SAR) on ultra-low-field (ULF) MRI. Methods: MT imaging was implemented by using sinc-modulated RF pulse train (SPT) modules to provide bilateral off-resonance irradiation. They were incorporated into 3D gradient echo (GRE) and fast spin echo (FSE) protocols on a shielding-free 0.055T head scanner. MT effects were first verified using phantoms. Brain MT imaging was conducted in both healthy subjects and patients. Results: MT effects were clearly observed in phantoms using six SPT modules with total flip angle 3600 degrees at central primary saturation bands of approximate offset +/- 786Hz, even in the presence of large relative B-0 inhomogeneity. For brain, strong MT effects were observed in gray matter, white matter, and muscle in 3D GRE and FSE imaging using six and sixteen SPT modules with total flip angle 3600 degrees and 9600 degrees, respectively. Fat, cerebrospinal fluid, and blood exhibited relatively weak MT effects. MT preparation enhanced tissue contrasts in T2-weighted and FLAIR-like images, and improved brain lesion delineation. The estimated MT SAR was 0.0024 and 0.0008W/kg for two protocols, respectively, which is far below the US Food and Drug Administration (FDA) limit of 3.0W/kg. Conclusion: Robust MT effects can be readily obtained at ULF with extremely low SAR, despite poor relative B-0 homogeneity in ppm. This unique advantage enables flexible MT pulse design and implementation on low-cost ULF MRI platforms to achieve strong MT effects in brain and beyond, potentially augmenting their clinical utility in the future.
引用
收藏
页码:2420 / 2432
页数:13
相关论文
共 51 条
  • [1] Low-field MRI: Clinical promise and challenges
    Arnold, Thomas Campbell
    Freeman, Colbey W.
    Litt, Brian
    Stein, Joel M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (01) : 25 - 44
  • [2] A portable scanner for magnetic resonance imaging of the brain
    Cooley, Clarissa Z.
    McDaniel, Patrick C.
    Stockmann, Jason P.
    Srinivas, Sai Abitha
    Cauley, Stephen F.
    Sliwiak, Monika
    Sappo, Charlotte R.
    Vaughn, Christopher F.
    Guerin, Bastien
    Rosen, Matthew S.
    Lev, Michael H.
    Wald, Lawrence L.
    [J]. NATURE BIOMEDICAL ENGINEERING, 2021, 5 (03) : 229 - 239
  • [3] Optimization of magnetization transfer contrast for EPI FLAIR brain imaging
    Demir, Serdest
    Clifford, Bryan
    Lo, Wei-Ching
    Tabari, Azadeh
    Goncalves Filho, Augusto Lio M.
    Lang, Min
    Cauley, Stephen F.
    Setsompop, Kawin
    Bilgic, Berkin
    Lev, Michael H.
    Schaefer, Pamela W.
    Rapalino, Otto
    Huang, Susie Y.
    Hilbert, Tom
    Feiweier, Thorsten
    Conklin, John
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2380 - 2387
  • [4] Deep learning-based single image super-resolution for low-field MR brain images
    den Bouter, M. L. de Leeuw
    Ippolito, G.
    O'Reilly, T. P. A.
    Remis, R. F.
    van Gijzen, M. B.
    Webb, A. G.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Accessible magnetic resonance imaging: A review
    Geethanath, Sairam
    Vaughan, John Thomas, Jr.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (07) : E65 - E77
  • [6] Magnetization transfer from inhomogeneously broadened lines (ihMT): Experimental optimization of saturation parameters for human brain imaging at 1.5 Tesla
    Girard, Olivier M.
    Prevost, Valentin H.
    Varma, Gopal
    Cozzone, Patrick J.
    Alsop, David C.
    Duhamel, Guillaume
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2111 - 2121
  • [7] Pulsed magnetization transfer imaging: Evaluation of technique
    Graham, SJ
    Henkelman, RM
    [J]. RADIOLOGY, 1999, 212 (03) : 903 - 910
  • [8] Understanding pulsed magnetization transfer
    Graham, SJ
    Henkelman, RM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05): : 903 - 912
  • [9] Use of 2.1 MHz MRI scanner for brain imaging and its preliminary results in stroke
    He, Yucheng
    He, Wei
    Tan, Liang
    Chen, Fangge
    Meng, Fanqin
    Feng, Hua
    Xu, Zheng
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2020, 319 (319)
  • [10] Magnetization transfer in MRI: a review
    Henkelman, RM
    Stanisz, GJ
    Graham, SJ
    [J]. NMR IN BIOMEDICINE, 2001, 14 (02) : 57 - 64