Robustness of radiomic features in healthy abdominal parenchyma of patients with repeated examinations on dual-layer dual-energy CT

被引:2
|
作者
Schoeneck, Mirjam [1 ,2 ]
Lennartz, Simon [1 ,2 ]
Zopfs, David [1 ,2 ]
Sonnabend, Kristina [1 ,2 ,3 ]
Reimer, Robert Wawer Matos [1 ]
Rinneburger, Miriam [1 ,2 ]
Graffe, Josefine [1 ,2 ]
Persigehl, Thorsten [1 ,2 ]
Hentschke, Clemens [4 ]
Baessler, Bettina [5 ]
Caldeira, Liliana Lourenco [1 ,2 ]
Hokamp, Nils Grosse [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[3] Philips Healthcare Market DACH, Rontgenstr 22, D-22335 Hamburg, Germany
[4] Mint Med GmbH, Burgstr 61, D-69121 Heidelberg, Germany
[5] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
关键词
Radiomics; Dual-energy CT; Computed Tomography; Reproducibility; STABILITY; IMAGES;
D O I
10.1016/j.ejrad.2024.111447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Robustness of radiomic features in physiological tissue is an important prerequisite for quantitative analysis of tumor biology and response assessment. In contrast to previous studies which focused on different tumors with mostly short scan-re-scan intervals, this study aimed to evaluate the robustness of radiomic features in cancer-free patients and over a clinically encountered inter-scan interval.<br /> Materials and methods: Patients without visible tumor burden who underwent at least two portal-venous phase dual energy CT examinations of the abdomen between May 2016 and January 2020 were included, while macroscopic tumor burden was excluded based upon follow-up imaging for all patients (>= 3 months). Further, patients were excluded if no follow-up imaging was available, or if the CT protocol showed deviations between repeated examinations. Circular regions of interest were placed and proofread by two board-certified radiologists (4 years and 5 years experience) within the liver (segments 3 and 6), the psoas muscle (left and right), the pancreatic head, and the spleen to obtain radiomic features from normal-appearing organ parenchyma using PyRadiomics. Radiomic feature robustness was tested using the concordance correlation coefficient with a threshold of 0.75 considered indicative for deeming a feature robust.<br /> Results: In total, 160 patients with 480 repeated abdominal CT examinations (range: 2-4 per patient) were retrospectively included in this single-center, IRB-approved study. Considering all organs and feature categories, only 4.58 % (25/546) of all features were robust with the highest rate being found in the first order feature category (20.37 %, 22/108). Other feature categories (grey level co-occurrence matrix, grey level dependence matrix, grey level run length matrix, grey level size zone matrix, and neighborhood gray-tone difference matrix) yielded an overall low percentage of robust features (range: 0.00 %-1.19 %). A subgroup analysis revealed the reconstructed field of view and the X-ray tube current as determinants of feature robustness (significant differences in subgroups for all organs, p < 0.001) as well as the size of the region of interest (no significant difference for the pancreatic head with p = 0.135, significant difference with p < 0.001 for all other organs). Conclusion: Radiomic feature robustness obtained from cancer-free subjects with repeated examinations using a consistent protocol and CT scanner was limited, with first order features yielding the highest proportion of robust features.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Robustness of dual-energy CT-derived radiomic features across three different scanner types
    Lennartz, Simon
    O'Shea, Aileen
    Parakh, Anushri
    Persigehl, Thorsten
    Baessler, Bettina
    Kambadakone, Avinash
    EUROPEAN RADIOLOGY, 2022, 32 (03) : 1959 - 1970
  • [2] Robustness of dual-energy CT-derived radiomic features across three different scanner types
    Simon Lennartz
    Aileen O’Shea
    Anushri Parakh
    Thorsten Persigehl
    Bettina Baessler
    Avinash Kambadakone
    European Radiology, 2022, 32 : 1959 - 1970
  • [3] Dual-energy micro-CT with a dual-layer, dual-color, single-crystal scintillator
    Maier, Daniel Simon
    Schock, Jonathan
    Pfeiffer, Franz
    OPTICS EXPRESS, 2017, 25 (06): : 6924 - 6935
  • [4] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899
  • [5] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Francesco Marcello Arico’
    Renato Trimarchi
    Antonio Portaluri
    Claudia Barilla’
    Nicola Migliaccio
    Giuseppe Mauro Bucolo
    Giuseppe Cicero
    Carmelo Sofia
    Christian Booz
    Thomas J. Vogl
    Maria Adele Marino
    Velio Ascenti
    Tommaso D’Angelo
    Silvio Mazziotti
    Giorgio Ascenti
    La radiologia medica, 2023, 128 : 891 - 899
  • [6] Diagnostic performance and feasibility of dual-layer detector dual-energy CT for characterization of urinary stones in patients of different sizes
    Pisuchpen, Nisanard
    Parakh, Anushri
    Cao, Jinjin
    Yuenyongsinchai, Kampon
    Joseph, Evita
    Lennartz, Simon
    Kongboonvijit, Sasiprang
    Sahani, Dushyant
    Kambadakone, Avinash
    ABDOMINAL RADIOLOGY, 2024, 49 (01) : 209 - 219
  • [7] Diagnostic performance and feasibility of dual-layer detector dual-energy CT for characterization of urinary stones in patients of different sizes
    Nisanard Pisuchpen
    Anushri Parakh
    Jinjin Cao
    Kampon Yuenyongsinchai
    Evita Joseph
    Simon Lennartz
    Sasiprang Kongboonvijit
    Dushyant Sahani
    Avinash Kambadakone
    Abdominal Radiology, 2024, 49 : 209 - 219
  • [8] Renal Lesion Characterization by Dual-Layer Dual-Energy CT: Comparison of Virtual and True Unenhanced Images
    Cao, Jinjin
    Lennartz, Simon
    Pisuchpen, Nisanard
    Mroueh, Nayla
    Kongboonvijit, Sasiprang
    Parakh, Anushri
    Sahani, Dushyant, V
    Kambadakone, Avinash
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) : 614 - 623
  • [9] Quantitative Dual-Energy Cone-Beam CT with a Prototype Dual-Layer Flat Panel Detector
    Wang, A.
    Shi, L.
    Bennett, N.
    Shapiro, E.
    Shiroma, A.
    Zhang, J.
    Colbeth, R.
    Star-Lack, J.
    Lu, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E110 - E110
  • [10] Value of Dual-Energy Dual-Layer CT After Mechanical Recanalization for the Quantification of Ischemic Brain Edema
    Steffen, Paul
    Austein, Friederike
    Lindner, Thomas
    Meyer, Lukas
    Bechstein, Matthias
    Ruemenapp, Johanna
    Klintz, Tristan
    Jansen, Olav
    Gellissen, Susanne
    Hanning, Uta
    Fiehler, Jens
    Broocks, Gabriel
    FRONTIERS IN NEUROLOGY, 2021, 12