Measuring blood pressure from Korotkoff sounds as the brachial cuff inflates on average provides higher values than when the cuff deflates

被引:1
作者
Celler, Branko G. [1 ]
Argha, Ahmadreza [2 ]
机构
[1] Univ New South Wales, Sch Elect Engn & Telecommun, Biomed Syst Res Lab, Sydney, NSW 2052, Australia
[2] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
关键词
blood pressure; Korotkoff sounds; brachial sphygmomanometry; cuff inflation; cuff deflation; ALGORITHM; VALIDATION; ACCURACY;
D O I
10.1088/1361-6579/ad39a2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objectives. In this study, we test the hypothesis that if, as demonstrated in a previous study, brachial arteries exhibit hysteresis as the occluding cuff is deflated and fail to open until cuff pressure (CP) is well below true intra-arterial blood pressure (IAPB), estimating systolic (SBP) and diastolic blood pressure (DBP) from the presence of Korotkoff sounds (KS) as CP increases may eliminate these errors and give more accurate estimates of SBP and DBP relative to IABP readings. Approach. In 62 subjects of varying ages (45.1 +/- 19.8, range 20.6-75.8 years), including 44 men (45.3 +/- 19.4, range 20.6-75.8 years) and 18 women (44.4 +/- 21.4, range 20.9-75.3 years), we sequentially recorded SBP and DBP both during cuff inflation and cuff deflation using KS. Results. There was a significant (p < 0.0001) increase in SBP from 122.8 +/- 13.2 to 127.6 +/- 13.0 mmHg and a significant (p = 0.0001) increase in DBP from 70.0 +/- 9.0 to 77.5 +/- 9.7 mmHg. Of the 62 subjects, 51 showed a positive increase in SBP (0-14 mmHg) and 11 subjects showed a reduction (-0.3 to -7 mmHg). The average differences for SBP and DBP estimates derived as the cuff inflates and those derived as the cuff deflates were 4.8 +/- 4.6 mmHg and 2.5 +/- 4.6 mmHg, not dissimilar to the differences reported between IABP and non-invasive blood pressure measurements. Although we could not develop multiparameter linear or non-linear models to explain this phenomenon we have clearly demonstrated through ANOVA tests that both body mass index (BMI) and pulse wave velocity are implicated, supporting the hypothesis that the phenomenon is associated with age, higher BMI and stiffer arteries. Significance. The implications of this study are that brachial sphygmomanometry carried out during cuff inflation could be more accurate than measurements carried out as the cuff deflates. Further research is required to validate these results with IAPB measurements.
引用
收藏
页数:10
相关论文
共 40 条
  • [21] Small intra-individual variability of the pre-ejection period justifies the use of pulse transit time as approximation of the vascular transit
    Kortekaas, Minke C.
    van Velzen, Marit H. N.
    Grune, Frank
    Niehof, Sjoerd P.
    Stolker, Robert J.
    Huygen, Frank J. P. M.
    [J]. PLOS ONE, 2018, 13 (10):
  • [22] Variable Selection for Clustering with Gaussian Mixture Models
    Maugis, Cathy
    Celeux, Gilles
    Martin-Magniette, Marie-Laure
    [J]. BIOMETRICS, 2009, 65 (03) : 701 - 709
  • [23] Brachial blood flow under relative levels of blood flow restriction is decreased in a nonlinear fashion
    Mouser, J. Grant
    Ade, Carl J.
    Black, Christopher D.
    Bemben, Debra A.
    Bemben, Michael G.
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (03) : 425 - 430
  • [24] Inflationary noninvasive blood pressure measurement reduces the incidence of subcutaneous hemorrhage
    Nukita, Shizuko
    Nakano, Sumie
    Morimoto, Yasuhiro
    Shiramoto, Hiroko
    [J]. BLOOD PRESSURE MONITORING, 2020, 25 (01) : 39 - 41
  • [25] NORMAL BLOOD PRESSURE IN THE SUPERFICIAL VENOUS SYSTEM OF MAN AT REST IN THE SUPINE POSITION
    OCHSNER, A
    COLP, R
    BURCH, GE
    [J]. CIRCULATION, 1951, 3 (05) : 674 - 680
  • [26] Accuracy of Cuff-Measured Blood Pressure Systematic Reviews and Meta-Analyses
    Picone, Dean S.
    Schultz, Martin G.
    Otahal, Petr
    Aakhus, Svend
    Al-Jumaily, Ahmed M.
    Black, J. Andrew
    Bos, Willem J.
    Chambers, John B.
    Chen, Chen-Huan
    Cheng, Hao-Min
    Cremer, Antoine
    Davies, Justin E.
    Dwyer, Nathan
    Gould, Brian A.
    Hughes, Alun D.
    Lacy, Peter S.
    Laugesen, Esben
    Liang, Fuyou
    Melamed, Roman
    Muecke, Sandy
    Ohte, Nobuyuki
    Okada, Sho
    Omboni, Stefano
    Ott, Christian
    Peng, Xiaoqing
    Pereira, Telmo
    Pucci, Giacomo
    Rajani, Ronak
    Roberts-Thomson, Philip a
    Rossen, Niklas B.
    Sueta, Daisuke
    Sinha, Manish D.
    Schmieder, Roland E.
    Smulyan, Harold
    Srikanth, Velandai K.
    Stewart, Ralph
    Stouffer, George A.
    Takazawa, Kenji
    Wang, Jiguang
    Westerhof, Berend E.
    Weber, Franz
    Weber, Thomas
    Williams, Bryan
    Yamada, Hirotsugu
    Yamamoto, Eiichiro
    Sharman, James E.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (05) : 572 - 586
  • [27] Health outcomes associated with antihypertensive therapies used as first-line agents - A systematic review and meta-analysis
    Psaty, BM
    Smith, NL
    Siscovick, DS
    Koepsell, TD
    Weiss, NS
    Heckbert, SR
    Lemaitre, RN
    Wagner, EH
    Furberg, CD
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (09): : 739 - 745
  • [28] Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit
    Saherwala, Ali A.
    Stutzman, Sonja E.
    Osman, Mohamed
    Kalia, Junaid
    Figueroa, Stephen A.
    Olson, DaiWai M.
    Aiyagari, Venkatesh
    [J]. NEUROCRITICAL CARE, 2018, 28 (03) : 265 - 272
  • [29] Factors influencing the accuracy of non-invasive blood pressure measurements in patients admitted for cardiogenic shock
    Seidlerova, Jitka
    Tumova, Pavlina
    Rokyta, Richard
    Hromadka, Milan
    [J]. BMC CARDIOVASCULAR DISORDERS, 2019, 19 (1)
  • [30] Soueidan K., 2010, 2010 IEEE INT WORKSH, P14