Diagnostic accuracy of voluntary and stimulated neuromuscular jitter studies in ocular myasthenia gravis

被引:0
作者
Cosentino, Giuseppe [1 ,2 ]
Prunetti, Paolo [2 ]
Tammam, Giulia [2 ]
Zaffina, Chiara [2 ]
Gastaldi, Matteo [3 ,4 ]
Tassorelli, Cristina [1 ,5 ]
Alfonsi, Enrico [2 ]
Todisco, Massimiliano [2 ]
机构
[1] Univ Pavia, Dept Brain & Behav Sci, Pavia, Italy
[2] IRCCS Mondino Fdn, Translat Neurophysiol Res Unit, Pavia, Italy
[3] IRCCS Mondino Fdn, Neuroimmunol Lab, Pavia, Italy
[4] IRCCS Mondino Fdn, Neuroimmunol Res Unit, Pavia, Italy
[5] IRCCS Mondino Fdn, Headache Sci & Neurorehabil Ctr, Pavia, Italy
关键词
axonal stimulation; jitter; myasthenia gravis; ocular muscles; single-fiber electromyography; voluntary activation; SINGLE-FIBER ELECTROMYOGRAPHY; CONCENTRIC NEEDLE ELECTRODES; REFERENCE VALUES; EMG; SENSITIVITY; SFEMG;
D O I
10.1002/mus.28202
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/Aims: There is a lack of studies comparing the accuracy of neuromuscular jitter analysis during voluntary activation (v-jitter study) versus axonal stimulation (s-jitter study). The study aimed to compare these two techniques in the same population of patients with suspected ocular myasthenia gravis (OMG). Methods: Fourteen control subjects (mean age: 55.5 +/- 15.2 years) and 34 patients with suspected OMG (mean age: 59 +/- 13.9 years) were prospectively evaluated. Twenty spike pairs and 30 individual spikes were analyzed during v-jitter and s-jitter study, respectively. Two different criteria for abnormal individual jitter values were evaluated: >= or > than 10% values exceeding the upper normal limit. Results: OMG was diagnosed in 19 patients based on clinical and laboratory findings, without considering jitter measurements. In most patients, v-jitter and s-jitter analyses provided comparable results. The maximum sensitivity (89%) was achieved with s-jitter study using the >= 10% criterion, while the maximum specificity (93%) was found with v-jitter study using the >10% criterion. Discussion: Both v-jitter and s-jitter studies showed good to very good accuracy for the diagnosis of OMG, in the absence of any statistically significant difference. Therefore, the patient's cooperation level and examiner's experience should guide the choice of performing v-jitter or s-jitter analysis in patients with suspected OMG.
引用
收藏
页码:733 / 743
页数:11
相关论文
共 33 条
[1]   Identifying jitter outliers in single fiber electromyography: Comparison of four methods [J].
Anagnostou, Evangelos ;
Dimopoulou, Panagiota ;
Sklavos, Sokratis ;
Zouvelou, Vasiliki ;
Zambelis, Thomas .
MUSCLE & NERVE, 2021, 63 (02) :217-224
[2]   Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis [J].
Benatar, Michael ;
Hammad, Mustafa ;
Doss-Riney, Heidi .
MUSCLE & NERVE, 2006, 34 (02) :163-168
[3]   REFERENCE VALUES OF MOTOR UNIT ACTION-POTENTIALS OBTAINED WITH MULTI-MUAP ANALYSIS [J].
BISCHOFF, C ;
STALBERG, E ;
FALCK, B ;
EEGOLOFSSON, KE .
MUSCLE & NERVE, 1994, 17 (08) :842-851
[4]   SINGLE-FIBER EMG REFERENCE VALUES - REFORMATTED IN TABULAR FORM [J].
BROMBERG, MB ;
SCOTT, DM .
MUSCLE & NERVE, 1994, 17 (07) :820-821
[5]  
Ertas M, 2000, MUSCLE NERVE, V23, P715
[6]   Sensitivity and specificity of single-fibre EMG in the diagnosis of ocular myasthenia varies accordingly to clinical presentation [J].
Giannoccaro, Maria Pia ;
Di Stasi, Vitantonio ;
Zanesini, Corrado ;
Donadio, Vincenzo ;
Avoni, Patrizia ;
Liguori, Rocco .
JOURNAL OF NEUROLOGY, 2020, 267 (03) :739-745
[7]   STIMULATION SFEMG IN MYASTHENIA-GRAVIS [J].
JABRE, JF ;
CHIRICOPOST, J ;
WEINER, M .
MUSCLE & NERVE, 1989, 12 (01) :38-42
[8]   Reference values for voluntary and stimulated single-fibre EMG using concentric needle electrodes: A multicentre prospective study [J].
Kokubun, Norito ;
Sonoo, Masahiro ;
Imai, Tomihiro ;
Arimura, Yumiko ;
Kuwabara, Satoshi ;
Komori, Tetsuo ;
Kobayashi, Masahito ;
Nagashima, Takahide ;
Hatanaka, Yuki ;
Tsuda, Emiko ;
Misawa, Sonoko ;
Abe, Tatsuya ;
Arimura, Kimiyoshi .
CLINICAL NEUROPHYSIOLOGY, 2012, 123 (03) :613-620
[9]   Concentric needle single fiber electromyography:: Comparative jitter on voluntary-activated and stimulated Extensor Digitorum Communis [J].
Kouyoumdjian, Joao Aris ;
Stalberg, Erik V. .
CLINICAL NEUROPHYSIOLOGY, 2008, 119 (07) :1614-1618
[10]   Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles [J].
Kouyoumdjian, Joao Aris ;
Stalberg, Erik V. .
MUSCLE & NERVE, 2008, 37 (06) :694-699