摘要
This study investigates the influence of steel fiber content (0%, 0.3%, 0.6%, 0.9%) on the axial compressive performance of ceramsite concrete. Four types of ceramsite concrete specimens were prepared and the cube compressive strength of each type of ceramsite concrete was tested. Four sets of uniaxial compression tests on prismatic specimens of ceramsite concrete were conducted. The failure process and characteristics of the specimens were analyzed, and the uniaxial compressive performance of each group of specimens was systematically studied. Additionally, the stress-strain curves equations were proposed. The research indicates that, after the addition of steel fibers, the strength and ductility of ceramsite concrete are significantly enhanced. The compressive strength of cubic specimens can increase by up to 42.6%, axial compressive strength can increase by up to 25.6%, and residual stress can increase by more than 300%. Ceramsite concrete with a steel fiber volume fraction of 0.9% demonstrates clear advantages. Its energy dissipation coefficient has increased by 17%, ductility coefficient has improved by 33%, toughness coefficient has enhanced by 68%, and stiffness degradation has noticeably become more gradual. The stress-strain curve model proposed in this study aligns well with the experimental results, accurately describing the stress-deformation characteristics of steel fiber ceramsite concrete under uniaxial compression. It demonstrates good applicability. The research findings of this study can provide a theoretical foundation for the structural analysis and design of such concrete, which is of significant importance for the utilization of ceramsite concrete as both a structural material and as a component in prefabricated lightweight wall panels.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Research on axial compressive performance of ceramic concrete reinforced with HTPP fibers
    Lin, Hongjian
    Fan, Le
    Zhang, Zhicheng
    Yuan, Ji
    He, Haijjie
    Yu, Jing
    Hu, Zhongzhi
    Xu, Wen
    Lin, Wei
    Yu, Kaisheng
    Wang, Ruixin
    Yang, Keyue
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 21
  • [32] Fatigue life analysis of polypropylene fiber reinforced concrete under axial constant-amplitude cyclic compression
    Cui, Kai
    Xu, Lihua
    Li, Xuefeng
    Hu, Xuan
    Huang, Le
    Deng, Fangqian
    Chi, Yin
    JOURNAL OF CLEANER PRODUCTION, 2021, 319
  • [33] Experimental Study on Hybrid Fiber-Reinforced Concrete Subjected to Uniaxial Compression
    Chi, Yin
    Xu, Lihua
    Zhang, Yuanyuan
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2014, 26 (02) : 211 - 218
  • [34] Effect of uncertainty on load position in the fatigue life of steel-fiber reinforced concrete under compression
    Tarifa, Manuel
    Ruiz, Gonzalo
    Poveda, Elisa
    Zhang, Xiaoxin
    Vicente, Miguel A.
    Gonzalez, Dorys C.
    MATERIALS AND STRUCTURES, 2018, 51 (01)
  • [35] Behavior of Steel Fiber-Reinforced High-Strength Concrete Columns under Uniaxial Compression
    Paultre, P.
    Eid, R.
    Langlois, Y.
    Levesque, Y.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (10): : 1225 - 1235
  • [36] Research on Behaviors of Steel Fiber Reinforced Concrete Filled Steel Tube Columns under Axial Load
    Lu, Yiyan
    Li, Shan
    Chen, Juan
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 596 - +
  • [37] Axial behavior of slender steel tube filled with steel-fiber-reinforced recycled aggregate concrete
    Liu, Zhenzhen
    Lu, Yiyan
    Li, Shan
    Liao, Jiancong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [38] STRESS-STRAIN MODEL FOR CONFINED FIBER-REINFORCED CONCRETE UNDER AXIAL COMPRESSION
    Sabariman, B.
    Soehardjono, A.
    Wisnumurti
    Wibowo, A.
    Tavio
    ARCHIVES OF CIVIL ENGINEERING, 2020, 66 (02) : 119 - 133
  • [39] Hybrid fiber reinforced concrete-filled square stub columns under axial compression
    Guler, Soner
    Yavuz, Demet
    Aydin, Muhammet
    ENGINEERING STRUCTURES, 2019, 198
  • [40] Parametric Study on Shear Performance for Steel Fiber Reinforced Concrete Beams
    Seo, Junwon
    Lee, Jaeha
    Lopez, Maria M.
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (07) : 1115 - 1127