Electrochemical detection of heavy metal ions in water using MWCNT/ ZnO nanocomposite

被引:9
作者
Zhou, Xiang [1 ]
机构
[1] Chongqing Water Resources & Elect Engn Coll, Chongqing 402160, Peoples R China
关键词
Carbon nanocomposite; Heavy metal detection; Voltammetry; Water analysis; Electrode modification; ELECTRODE; PB(II); NANOPARTICLES; PERFORMANCE; CU(II); CD(II); HG(II);
D O I
10.1016/j.ijoes.2024.100559
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A nanocomposite of multi -walled carbon nanotubes (MWCNTs) decorated with zinc oxide nanoparticles (ZnO NPs) was fabricated via an in -situ hydrothermal approach and implemented as a modified electrode for stripping voltammetric detection of dissolved heavy metal ions. The MWCNT/ZnO exhibited a high specific surface area of 53 m2/g and charge transfer conductivity amplified to 26 S/cm. By square wave voltammetry, the nanocomposite sensor achieved wide linear detection of Cu(II) from 1 to 800 ppb, Pb(II) from 5 to 1000 ppb, and Hg (II) from 1 to 900 ppb, along with low limits of detection reaching 0.8, 1.2, and 0.7 ppb, respectively. The 3 -5X enhanced sensitivity versus an unmodified screen -printed carbon electrode confirms performance gains supplied by the tailored hybrid interface. Selectivity testing produced distinct, well -resolved oxidation peaks for each metal ion target that remained unaffected by high off -target concentrations of Mn(II), Co(II), and Fe(III) interferents. Accurate spike recoveries between 95% and 102% were obtained from quantifying ternary mixtures across various Cu(II):Pb(II):Hg(II) compositions, substantiating the capability for simultaneous multianalyte analysis. The simple preparation, high sensitivity and selectivity, and accuracy for direct water testing validates the nanocomposite as a practical portable sensor for on -site toxic heavy metal detection.
引用
收藏
页数:8
相关论文
共 38 条
[31]  
Saravanakkumar D., 2018, IOSR J. Appl. Phys., V10, P73, DOI [10.9790/, DOI 10.9790/4861-1003027383]
[32]   ZnO/CNT-COOHs based solid-state ECL sensor for tetracycline detection in fishpond water [J].
Shan, Xueling ;
Pan, Yuting ;
Dai, Fanzhuo ;
Chen, Xiaohui ;
Wang, Wenchang ;
Chen, Zhidong .
MICROCHEMICAL JOURNAL, 2020, 155
[33]   China is establishing its water quality standards for enhancing protection of aquatic life in freshwater ecosystems [J].
Sun, Fuhong ;
Mu, Yunsong ;
Leung, Kenneth M. Y. ;
Su, Hailei ;
Wu, Fengchang ;
Chang, Hong .
ENVIRONMENTAL SCIENCE & POLICY, 2021, 124 :413-422
[34]   Multiwall carbon nanotube modified by antimony oxide (Sb2O3/MWCNTs) paste electrode for the simultaneous electrochemical detection of cadmium and lead ions [J].
Tran Le Hai ;
Ly Cam Hung ;
Tran Thi Bich Phuong ;
Bui Thi Thu Ha ;
Ba-Son Nguyen ;
Tran Duy Hai ;
Van-Huy Nguyen .
MICROCHEMICAL JOURNAL, 2020, 153
[35]   Electrochemical evaluation of total antioxidant properties in red wine [J].
Wu, Hui .
JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2023, 17 (05) :5344-5351
[36]   Novel Oligomer Enables Green Solvent Processed 17.5% Ternary Organic Solar Cells: Synergistic Energy Loss Reduction and Morphology Fine-Tuning [J].
Xia, Hao ;
Zhang, Ying ;
Deng, Wanyuan ;
Liu, Kuan ;
Xia, Xinxin ;
Su, Chun-Jen ;
Jeng, U-Ser ;
Zhang, Miao ;
Huang, Jiaming ;
Huang, Jingwei ;
Yan, Cenqi ;
Wong, Wai-Yeung ;
Lu, Xinhui ;
Zhu, Weiguo ;
Li, Gang .
ADVANCED MATERIALS, 2022, 34 (10)
[37]   Reductive determination of hydrogen peroxide with MWCNTs-Pd nanoparticles on a modified glassy carbon electrode [J].
You, Jung-Min ;
Jeong, Yu Na ;
Ahmed, Mohammad Shamsuddin ;
Kim, Seul Ki ;
Choi, Hyun Chul ;
Jeon, Seungwon .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) :2287-2291
[38]   Alkaline intercalation of Ti3C2 MXene for simultaneous electrochemical detection of Cd(II), Pb(II), Cu(II) and Hg(II) [J].
Zhu, Xiaolei ;
Liu, Bingchuan ;
Hou, Huijie ;
Huang, Zhenying ;
Zeinu, Kemal Mohammed ;
Huang, Long ;
Yuan, Xiqing ;
Guo, Dabin ;
Hu, Jingping ;
Yang, Jiakuan .
ELECTROCHIMICA ACTA, 2017, 248 :46-57