Simultaneous multiple target detection platform based on vertical flow immunoassay

被引:0
作者
Yong, Taek [1 ]
Kim, Dami [2 ]
Kim, Sanghyo [1 ,2 ]
机构
[1] Gachon Univ, Dept Bionanotechnol, Seongnam 13120, South Korea
[2] Philmedi Inc, Philmedi R&D Ctr, 33 Sagimakgol Ro 62 Beon Gil, Seongnam 13211, South Korea
关键词
Vertical flow assay; Antigen -antibody binding; One-step detection; Gold nanoparticles; Multiple detection; POINT;
D O I
10.1016/j.jim.2024.113690
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In general, vertical flow assay (VFA) has a disadvantage of requiring a complex analysis process that involves manually injecting various reagents (target analyte, washing buffer, detection conjugate, etc.) sequentially. However, in this study, we have developed an innovative paper-based VFA device that replaces the complex analysis process with one-step and enables the detection of multiple targets. The fabrication process of the multitarget detection VFA device is as follows: preparation and pre-treatment of the strip materials, design of strip cartridge, design of the multiple detection VFA device, optimization experiments for strip sample flow rates, determination of device analysis time, determination of device limit of detection (LOD), multiple target signal uniformity experiment, immunoglobulin G (IgG) and C-reactive protein (CRP) antigen-antibody multiple detection experiment, and data extraction and analysis method. The use of paper-based materials enables the device to be produced at cost-effective, and cartridge production allowed for uniform array formation. IgG and CRP are used to evaluate the performance of the device as common biomarkers. The device proposed in this study is currently under research. To validate multiple target detection capability of the VFA device proposed in this study, two types of antigens-antibodies (Human IgG and Human CRP) were employed. The detection limit is 0.15 mu g/mL for IgG and 0.19 mu g/mL for CRP in naked eye. Furthermore, it was confirmed that there is no crossreactivity caused by the device structure through IgG and CRP antigens. In conclusion, the VFA device proposed in this study consists of a one-step analysis process, and it has been confirmed that it can detect multiple targets simultaneously.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Research Progress on Simultaneous Detection of Multiple Mycotoxins in Food
    Dai H.
    Liang S.
    Wang C.
    Xu Q.
    Journal of Chinese Institute of Food Science and Technology, 2022, 22 (08) : 398 - 415
  • [42] Multiple test zones for improved detection performance in lateral flow assays
    Hu, Jie
    Choi, Jane Ru
    Wang, Shuqi
    Gong, Yan
    Feng, Shangsheng
    Pingguan-Murphy, Belinda
    Lu, Tian Jian
    Xu, Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 484 - 488
  • [43] Multiplexed aptasensor based on metal ions labels for simultaneous detection of multiple antibiotic residues in milk
    Li, Falan
    Guo, Yemin
    Wang, Xiangyou
    Sun, Xia
    BIOSENSORS & BIOELECTRONICS, 2018, 115 : 7 - 13
  • [44] Triplex-Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Immunoassay for the Simultaneous Detection of Three Pathogens of Porcine Viral Diarrhea Syndrome in Swine
    Hong, Yi
    Ma, Biao
    Li, Jiali
    Shuai, Jiangbing
    Zhang, Xiaofeng
    Xu, Hanyue
    Zhang, Mingzhou
    ANIMALS, 2023, 13 (12):
  • [45] Colour-encoded lateral flow immunoassay for the simultaneous detection of aflatoxin B1 and type-B fumonisins in a single Test line
    Di Nardo, Fabio
    Alladio, Eugenio
    Baggiani, Claudio
    Cavalera, Simone
    Giovannoli, Cristina
    Spano, Giulia
    Anfossi, Laura
    TALANTA, 2019, 192 : 288 - 294
  • [46] Lateral Flow Immunoassay for Rapid Detection of Grapevine Leafroll-Associated Virus
    Byzova, Nadezhda A.
    Vinogradova, Svetlana V.
    Porotikova, Elena V.
    Terekhova, Uliana D.
    Zherdev, Anatoly V.
    Dzantiev, Boris B.
    BIOSENSORS-BASEL, 2018, 8 (04):
  • [47] A vertical flow paper-microarray assay with isothermal DNA amplification for detection of Neisseria meningitidis
    Rivas, Lourdes
    Reutersward, Philippa
    Rasti, Reza
    Herrmann, Bjorn
    Martensson, Andreas
    Alfven, Tobias
    Gantelius, Jesper
    Andersson-Svahn, Helene
    TALANTA, 2018, 183 : 192 - 200
  • [48] Highly sensitive protein detection using recombinant spores and lateral flow immunoassay
    Lin, Wen-Zhi
    Ma, I-Cheng
    Wang, Jun-Pei
    Hsieh, Ping-Chun
    Liu, Cheng-Che
    Hou, Shao-Yi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (08) : 2235 - 2246
  • [49] Sensitive and Matrix-Tolerant Lateral Flow Immunoassay Based on Fluorescent Magnetic Nanobeads for the Detection of Clenbuterol in Swine Urine
    Huang, Zhen
    Xiong, Zhijuan
    Chen, Yuan
    Hu, Song
    Lai, Weihua
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (10) : 3028 - 3036
  • [50] Highly sensitive protein detection using recombinant spores and lateral flow immunoassay
    Wen-Zhi Lin
    I-Cheng Ma
    Jun-Pei Wang
    Ping-Chun Hsieh
    Cheng-Che Liu
    Shao-Yi Hou
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2235 - 2246