The Relationship Between Serum Magnesium Level, Plasma Atherogenic Index and Glomerular Filtration Rate

被引:0
|
作者
Bayrakci, Nergiz [1 ]
Even, Ozge [2 ]
Karabacak, Veli Yakup [1 ]
Celikkol, Aliye [3 ]
Ozkan, Gulsum [1 ]
机构
[1] Tekirdag Namik Kemal Univ, Fac Med, Dept Internal Med, Clin Nephrol, Tekirdag, Turkey
[2] Tekirdag Namik Kemal Univ, Fac Med, Dept Internal Med, Tekirdag, Turkey
[3] Tekirdag Namik Kemal Univ, Fac Med, Dept Biochem, Tekirdag, Turkey
来源
NAMIK KEMAL MEDICAL JOURNAL | 2022年 / 10卷 / 03期
关键词
Glomerular filtration rate; magnesium; atherogenic index of plasma; DISEASE; CALCIFICATION; METABOLISM; LIPIDS; RISK;
D O I
10.4274/nkmj.galenos.2022.96530
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Magnesium is associated with many chronic diseases, especially cardiovascular diseases. The purpose of this study is to evaluate the relationship between serum magnesium level, glomerular filtration rate (GFR) and atherogenic index of plasma (AIP). Materials and Methods: The data of 214 patients included in the study were analyzed retrospectively. Those with an estimated GFR of 60 mL/ minute/1.73 m2 and above were grouped as the "high GFR group", and those with an estimated GFR of less than 60 mL/minute/1.73 m2 were grouped as the "low GFR group". AIP was calculated by taking the logarithm of the ratio of serum triglyceride level to serum high-density lipoprotein level. Results: There were 72 patients in the high GFR group and 142 patients in the low GFR group. There was no difference between the groups in terms of serum magnesium level and AIP. The factors related to serum magnesium level and AIP were investigated in the whole study population. A negative correlation was found between serum magnesium level and AIP [Odds ratio (OR): -0.212]. When the factors associated with AIP were examined, AIP was found to be negatively correlated with serum magnesium level (OR: -0.189) whereas positively correlated with body mass index, systolic blood pressure and serum uric acid level (OR: 0.154; 0.276; 0.165, respectively). There was no relationship between AIP and magnesium Conclusion: The inverse relationship between serum magnesium level and AIP is consistent with the literature on the relationship between hypomagnesemia and atherogenicity. The lack of a relationship between AIP and serum magnesium level and GFR may be attributed to the small number of patients.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [41] Effect of differences in serum creatinine estimation methodologies on estimated glomerular filtration rate
    Lee, Su-Chu
    Lim, Lee-Moay
    Chang, Eddy-Essen
    Chiu, Yi-Wen
    Hwang, Shang-Jyh
    Chen, Hung-Chun
    SINGAPORE MEDICAL JOURNAL, 2019, 60 (09) : 468 - 473
  • [42] The relationship between estimated glomerular filtration rate and urine m/creatinine ratio and parathyroid hormone in elderly Koreans
    Lee, Jun Ho
    Park, Sang Muk
    Gi, Mi Young
    Cha, Ju Ae
    Moon, Ae Eun
    Yoon, Hyun
    HORMONES-INTERNATIONAL JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2019, 18 (04): : 485 - 494
  • [43] Correlations of serum cystatin C and glomerular filtration rate with vascular lesions and severity in acute coronary syndrome
    Zhang, Jinjin
    Wu, Xianhao
    Gao, Peizhen
    Yan, Pingping
    BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [44] Relationship Between Uric Acid, Proteinuria, and Atherogenic Index of Plasma in Renal Transplant Patients
    Biyik, Z.
    Guney, I.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) : 3376 - 3380
  • [45] Relationship between Plasma Proprotein Convertase Subtilisin/Kexin Type 9 and Estimated Glomerular Filtration Rate in the General Chinese Population
    Zhang, Hui-Wen
    Zhao, Xi
    Xu, Rui-Xia
    Guo, Yuan-Lin
    Zhu, Cheng-Gang
    Wu, Na-Qiong
    Cui, Chuan-Jue
    Dong, Qian
    Li, Jian-Jun
    CARDIORENAL MEDICINE, 2018, 8 (04) : 311 - 320
  • [46] Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: Why to measure glomerular filtration rate with iohexol?
    Delanaye, Pierre
    Melsom, Toralf
    Ebert, Natalie
    Back, Sten-Erik
    Mariat, Christophe
    Cavalier, Etienne
    Bjork, Jonas
    Christensson, Anders
    Nyman, Ulf
    Porrini, Esteban
    Remuzzi, Giuseppe
    Ruggenenti, Piero
    Schaeffner, Elke
    Soveri, Inga
    Sterner, Gunnar
    Eriksen, Bjorn Odvar
    Gaspari, Flavio
    CLINICAL KIDNEY JOURNAL, 2016, 9 (05) : 700 - 704
  • [47] Elevation of serum adiponectin in mildly decreased glomerular filtration rate
    Mahima, Apinya
    Kongkhum, Sudawadee
    Bordeerat, Narisa Kengtong
    Fongsupa, Somsak
    Rerksngarm, Thaval
    Siripurkpong, Pilaiwan
    ASIAN BIOMEDICINE, 2018, 12 (06) : 255 - 262
  • [48] Relationship between plasma atherogenic index and incidence of cardiovascular diseases in Chinese middle-aged and elderly people
    Zhao, Mengjie
    Xiao, Mengli
    Zhang, Huie
    Tan, Qin
    Ji, Jinjin
    Cheng, Yurong
    Lu, Fang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [49] Correlation between QT Variability Index and Glomerular Filtration Rate in Predialysis Chronic Kidney Disease
    Sugiantoro
    Purnomowati, Augustine
    Martakusumah, Abdul Hadi
    Achmad, Chaerul
    MAJALAH KEDOKTERAN BANDUNG-MKB-BANDUNG MEDICAL JOURNAL, 2012, 44 (04): : 193 - 198
  • [50] Relationship between atherogenic index of plasma and stent thrombosis in patients with acute coronary syndrome
    Abacioglu, Ozge Ozcan
    Yildirim, Arafat
    Koyunsever, Nermin Yildiz
    Karadeniz, Mine
    Kilic, Salih
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (02) : 112 - 117