Intra-arterial contrast enhanced computed tomography of the deep digital flexor tendon and palmar veins in the distal forelimb in Jeju horses: Evaluating contrast-enhancing factors

被引:0
作者
Lee, Seyoung [1 ,2 ]
Shin, Kwang-Yun [3 ]
Lee, Kija [4 ]
Seo, Jong-pil [1 ,2 ]
机构
[1] Jeju Natl Univ, Coll Vet Med, Vet Med Res Inst, Jeju 63243, South Korea
[2] Jeju Natl Univ, Vet Med Res Inst, Jeju 63243, South Korea
[3] Inst Livestock Promot, Jeju Special Selfgoverning Prov, Jeju, South Korea
[4] Kyungpook Natl Univ, Coll Vet Med, Daegu 41556, South Korea
关键词
contrast media; distal forelimb; horse; intra-arterial contrast-enhanced computed tomography; voltage; CT; NECK; MDCT;
D O I
10.1111/evj.14408
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Few studies have investigated the adequate contrast enhancement (CE) evaluation depending on concentration, volume, and rate of administration of contrast media (CM) and the scan parameters in equine contrast enhanced computed tomography (CECT). Objectives: To investigate CE of the deep digital flexor tendon (DDFT) and veins depending on the computed tomography (CT) voltage and concentration, volume, and rate of CM administration during intra-arterial CECT of equine distal forelimbs. Study Design In vivo experiments. Methods: Six horses underwent 54 CT scans. First, the CE of DDFT and veins was evaluated depending on the voltage (80 kV and 250 mA or 120 kV and 150 mA) and CM concentration (150, 120, or 90 mg I/mL in 50 mL of CM). Second, CE of DDFT and veins was evaluated depending on the CM volume (50, 100, or 150 mL) and administration rate (2, 4, or 6 mL/s) with a fixed iodine delivery rate (IDR; 300 or 180 mg I/s). Results: Contrast enhancement of DDFT was significantly higher at 80 kV of voltage and 150 mg I/mL of CM concentration (Median: 29.65; IQR: 1.74; p < 0.05). CE of the DDFT positively correlated with CM concentration (p < 0.001; r = 0.75). At 180 mg I/s IDR, contrast attenuation in the medial and lateral palmar veins significantly decreased at a CM of 30 mg I/mL, rate of 6 mL/s, and volume of 150 mL (median and IQR: 985.93 and 71.8 Hounsfield units [HU] and 988.73 and 41.16 HU, respectively); the CE was sufficient to distinguish between the vessels and the adjacent structures. Main Limitations: The number of animals was small. Conclusions: Our results suggest that a low CM concentration could yield sufficient CE of the DDFT and arteries with adjusted CT scanning parameters or volume and injection rate of CM.
引用
收藏
页码:789 / 797
页数:9
相关论文
共 20 条
[1]   Impact of Intra-Arterial Injection Parameters on Arterial, Capillary, and Venous Time-Concentration Curves in a Canine Model [J].
Ahmed, A. S. ;
Deuerling-Zheng, Y. ;
Strother, C. M. ;
Pulfer, K. A. ;
Zellerhoff, M. ;
Redel, T. ;
Royalty, K. ;
Consigny, D. ;
Lindstrom, M. J. ;
Niemann, D. B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (07) :1337-1341
[2]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[3]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[4]   Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen:: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml [J].
Behrendt, F. F. ;
Mahnken, A. H. ;
Keil, S. ;
Das, M. ;
Hohl, C. ;
Bauer, D. ;
Seidensticker, P. ;
Jost, E. ;
Wildberger, J. E. ;
Guenther, R. W. ;
Muehlenbruch, G. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1199-1205
[5]  
오운용, 2014, [Journal of Agriculture & Life Science, 농업생명과학연구], V48, P99, DOI 10.14397/jals.2014.48.1.99
[6]   Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol [J].
Gnannt, R. ;
Winklehner, A. ;
Goetti, R. ;
Schmidt, B. ;
Kollias, S. ;
Alkadhi, H. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1014-1019
[7]   Variation in Tube Voltage for Adult Neck MDCT: Effect on Radiation Dose and Image Quality [J].
Hoang, Jenny K. ;
Yoshizumi, Terry T. ;
Giao Nguyen ;
Toncheva, Greta ;
Choudhury, Kingshuk Roy ;
Gafton, Andreia R. ;
Eastwood, James D. ;
Lowry, Carolyn ;
Hurwitz, Lynne M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (03) :621-627
[8]  
Indrajit Inna K, 2015, Indian J Radiol Imaging, V25, P2, DOI 10.4103/0971-3026.150105
[9]   Use of non-contrast-enhanced computed tomography to identify deep digital flexor tendinopathy in horses with lameness: 28 cases (2014-2016) [J].
Jones, Andrew R. E. ;
Ragle, Claude A. ;
Mattoon, John S. ;
Sanz, Macarena G. .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2019, 254 (07) :852-858
[10]  
Kong Hong-Sik, 2011, Journal of Animal Science and Technology, V53, P23, DOI 10.5187/JAST.2011.53.1.23