Optimal operating scenario and performance comparison of biomass-fueled microturbine

被引:2
|
作者
Bollas, Konstantinos [1 ]
Banihabib, Reyhaneh [2 ]
Assadi, Mohsen [2 ]
Kalfas, Anestis [1 ]
机构
[1] Aristotle Univ Thessaloniki, Lab Fluid Mech & Turbomachinery, Thessaloniki 54124, Greece
[2] Univ Stavanger, Fac Sci & Technol, N-4016 Stavanger, Norway
关键词
Micro-Gas Turbine; Externally-fired; Biomass gasification utilization; Thermodynamic optimization; Exergy analysis; FIRED GAS-TURBINE; HEAT-TRANSFER; NATURAL-GAS; GASIFICATION; DESIGN; SYSTEM; CYCLE;
D O I
10.1016/j.energy.2024.131225
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper focuses on the determination of the optimal operating scenario of an Externally-Fired MicroGas turbine utilizing syngas produced by biomass gasification. Biomass exploitation can contribute to the achievement of the net-zero emissions target in 2050. This can be boosted by the advancement of externallyfired technology. In this study, a dual-objective optimization process, including a validated thermodynamic model, is combined with preliminary cost insights to assist the decision-making process. The resulting performance is compared with the actual data-based performance of a reference natural-gas-fired MicroGas Turbine. The performance comparison is performed through an exergetic analysis, identifying the main losses contributors. The optimization results in an externally-fired performance of 77.9 kW el electrical power and 20.3% efficiency, improved by 31.5% compared to the average current externally-fired demonstrated efficiencies. Yet, there is still room for improvement to reach natural-gas-fired Micro-Gas Turbine efficiency. The study highlights an unavoidable efficiency decrease of at least 4.0 percentage points due to the use of syngas itself instead of natural gas, which conversely increases heat recovery potential. However, compared to the state-of-the-art demonstrations, the proposed analysis is a significant step towards efficiency improvement, which can be exploited for future biomass demonstrations, attractive for electricity generation as well.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Model performance of a biomass-fueled power station with variable furnace exit gas temperature for fouling control
    Yomogida, DE
    Jenkins, BM
    Hartsough, BR
    Tiangco, VM
    BIOMASS: A GROWTH OPPORTUNITY IN GREEN ENERGY AND VALUE-ADDED PRODUCTS, VOLS 1 AND 2, 1999, : 1409 - 1416
  • [22] Fundamental Study toward Improving the Performance of a High-Moisture Biomass-Fueled Redox Flow Fuel Cell
    Liu, Wei
    Gong, Yutao
    Tricker, Andrew
    Wu, Gaoxiang
    Liu, Congmin
    Chao, Zi-Sheng
    Deng, Yulin
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (10) : 4817 - 4828
  • [23] Performance testing of microturbine generator system fueled by biodiesel
    Chiang, Hsiao-Wei D.
    Chiang, I-Che
    Li, Hsin-Lung
    PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 1, 2007, : 459 - 466
  • [24] Field Testing of a Biomass-Fueled Flamer for In-Row Weed Control in the Vineyard
    Pergher, Gianfranco
    Gubiani, Rino
    Mainardis, Matia
    AGRICULTURE-BASEL, 2019, 9 (10):
  • [25] Deterministic Optimization Approach for High-Performance Externally Fired Biomass-Fueled Micro-Gas Turbines
    Bollas, Konstantinos D. D.
    Efstathiadis, Theofilos G. G.
    Kalfas, Anestis I. I.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2023, 145 (08):
  • [26] Biomass-fueled, high-temperature, air-blown gasification systems
    Pian, CCP
    Yoshikawa, K
    35TH INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE & EXHIBIT (IECEC), VOLS 1 AND 2, TECHNICAL PAPERS, 2000, : 793 - 803
  • [27] Carbon Footprint Analysis for Biomass-Fueled Combined Heat and Power Station: A Case Study
    Zheng, Yingying
    Liu, Chang
    Zhu, Jie
    Sang, Yuanrui
    Wang, Jinglong
    Zhao, Wenjing
    Zhuang, Minghao
    AGRICULTURE-BASEL, 2022, 12 (08):
  • [28] Design and modelling of a small scale biomass-fueled CHP system based on Rankine technology
    Santos, Marcio
    Andre, Jorge
    Mendes, Ricardo
    Ribeiro, Jose B.
    4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 676 - 683
  • [29] Profitability of participation in control reserve market for biomass-fueled combined heat and power plants
    Muche, Thomas
    Hoege, Christin
    Renner, Oliver
    Pohl, Ralf
    RENEWABLE ENERGY, 2016, 90 : 62 - 76
  • [30] Colmac Energy Inc.'s Biomass-Fueled Power Plant, Mecca, California
    Neville, Angela
    POWER, 2010, 154 (12) : 30 - 31