Seismic strengthening of partially grouted masonry walls with openings: Evaluation of ferrocement and BTRM solutions

被引:3
作者
Perez-Pinedo, Luis [1 ]
Sandoval, Cristian [1 ,2 ]
Alvarado, Rolando [1 ]
Vargas, Laura [1 ]
Calderon, Sebastian [3 ]
Bernat, Ernest [4 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[3] Univ Concepcion, Dept Civil Engn, POB 160-C, Concepcion, Chile
[4] Univ Politecn Cataluna, Dept Strength Mat & Engn Struct, Barcelona, Spain
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 88卷
关键词
Reinforced masonry; Partially grouted; BTRM; Ferrocement; Seismic strengthening; PERFORMANCE;
D O I
10.1016/j.jobe.2024.109235
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental study on the seismic performance of partially grouted reinforced masonry (PG-RM) walls strengthened with two solutions: Ferrocement coating (welded wire steel mesh embedded in cementitious mortar, WWM) and Basalt Textile Reinforced Mortar (BTRM) layer. For this purpose, two full-scale walls were built with hollow concrete units, with identical geometry and construction details of a previously reported tested wall, which acts as the control specimen (unstrengthened case) in this study. The walls, with a window-type opening and another door-type opening, were strengthened on one of their sides and tested under the combined action of constant axial compression and cyclic lateral loading up to failure. The experimental results show that both strengthening solutions increased the investigated walls' initial stiffness and lateral capacity. The increase in lateral capacity of both solutions was similar, about 37%. The 2D-DIC analysis implemented during the tests was instrumental in highlighting the areas on the strengthened walls where high strains were developed. The damage registered on the BTRM layer was more consistent with what was observed on the surface of the unstrengthened wall. Meanwhile, the damage reported on the wall strengthened with WWM did not exhibit apparent damage at higher drift levels due to the detachment between the ferrocement coating and the masonry substrate. Finally, the performance of some procedures to compute the contribution of the studied strengthening solutions was also assessed.
引用
收藏
页数:23
相关论文
共 65 条
  • [61] The GreenBuilding Company, 2019, Steel DryFix 10. Tech. Rep. Via dell'Artigianato, 9-41049
  • [62] The GreenBuilding Company GeoCalce F Antisismico, 2019, Tech. rep. Via dell'Artigianato, 9-41049
  • [63] Valdebenito G., 2015, 11 C CHIL SISM ING S, P221
  • [64] Seismic behavior of partially grouted masonry shear walls containing openings: Experimental testing
    Vargas, Laura
    Bertolesi, Elisa
    Sandoval, Cristian
    Calderon, Sebastian
    [J]. ENGINEERING STRUCTURES, 2023, 278
  • [65] Hollow block masonry wall reinforced by built-in structural configuration: Seismic behavior analysis
    Zhou, Xiaojie
    Du, Jinpeng
    Peng, Quanmin
    Chen, Peiqi
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 126