Technical note: Can photon-counting CT improve PET/CT's quantitative accuracy?

被引:1
|
作者
Hamill, James [1 ]
Birge, Noah [1 ]
O'Doherty, Jim [2 ,3 ]
Nye, Jonathon [4 ]
Elojeimy, Saeed [4 ]
机构
[1] Siemens Med Solut USA, 810 Innovat Dr Knoxville, Tennessee, IL 37923 USA
[2] Siemens Med Solut USA, CT R&D Collaborat, Malvern, PA USA
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC USA
[4] Med Univ South Carolina, Dept Radiol & Radiol Sci, Dept Nucl Med, Charleston, SC USA
关键词
attenuation correction; PET; photon-counting CT; ATTENUATION CORRECTION; INTRAVENOUS CONTRAST;
D O I
10.1002/mp.17299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundLinear attenuation coefficients (LACs) in positron emission tomography combined with computed tomography (PET/CT) are derived from CT scans that utilize energy-integrating detectors (EID-CT). These LACs are inaccurate when iodine contrast has been injected. Photon counting detector CT (PCD-CT) may be able to improve the accuracy.PurposeTo investigate whether PCD-CT can improve PET/CT quantitative accuracy.MethodsTwo experiments were performed: one with CT only and one that combined PET and CT. The first experiment used an electron density phantom whose inserts were imaged with EID-CT and PCD-CT. The inserts simulated normal human tissues, including bone and iodinated blood. In the case of PCD-CT, virtual-monoenergetic images at 190 keV were created. LACs were derived in each case and compared against known values. For inserts with iodine, more accurate LACs were expected with PCD-CT. The second experiment involved a custom PET phantom with various materials simulating human tissues (blood, iodinated blood, and bone) and 18F radioactivity. Data were first acquired with an EID-CT-based PET/CT system and then separately in a PCD-CT system without PET. PET images were reconstructed using LAC from EID-CT and PCD-CT. PET image values were compared against known activity values using recovery coefficients (RC).ResultsIn the first experiment, LAC based on EID-CT were in error by as much as 18%, whereas the corresponding PCD-CT based measurements were within 3%. In the second experiment, minimum, maximum, and mean RC were (96.1%, 115.4%, and 103.8%) for the EID-CT method, and (95.8%, 105.5%, and 101.0%) for the PCD-CT method. The consistency of PET images in body and head orientations was improved.ConclusionsPCD-CT can acquire the information needed for accurate LAC for PET reconstruction in a single spiral acquisition.
引用
收藏
页码:7206 / 7213
页数:8
相关论文
共 50 条
  • [41] Coronary artery calcium scoring with photon-counting CT: first in vivo human experience
    Symons, Rolf
    Sandfort, Veit
    Mallek, Marissa
    Ulzheimer, Stefan
    Pourmorteza, Amir
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (04) : 733 - 739
  • [42] Combining photon-counting coronary CT and artificial intelligence to detect coronary artery stenosis
    Bluemke, David A.
    Nagpal, Prashant
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 45 - 46
  • [43] Coronary artery calcium scoring with photon-counting CT: first in vivo human experience
    Rolf Symons
    Veit Sandfort
    Marissa Mallek
    Stefan Ulzheimer
    Amir Pourmorteza
    The International Journal of Cardiovascular Imaging, 2019, 35 : 733 - 739
  • [44] Photon-counting Spectral CT with De-noised Principal Component Analysis (PCA)
    Xie, Huiqiao
    Liu, Yufei
    Thuering, Thomas
    Long, Wenting
    Tang, Xiangyang
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [45] Radiomics-driven spectral profiling of six kidney stone types with monoenergetic CT reconstructions in photon-counting CT
    Hertel, Alexander
    Froelich, Matthias F.
    Overhoff, Daniel
    Nestler, Tim
    Faby, Sebastian
    Juergens, Markus
    Schmidt, Bernhard
    Vellala, Abhinay
    Hesse, Albrecht
    Noerenberg, Dominik
    Stoll, Rico
    Schmelz, Hans
    Schoenberg, Stefan O.
    Waldeck, Stephan
    EUROPEAN RADIOLOGY, 2024, : 3120 - 3130
  • [46] Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study
    Symons, Rolf
    Krauss, Bernhard
    Sahbaee, Pooyan
    Cork, Tyler E.
    Lakshmanan, Manu N.
    Bluemke, David A.
    Pourmorteza, Amir
    MEDICAL PHYSICS, 2017, 44 (10) : 5120 - 5127
  • [47] Photon-counting CT for forensic death investigations-a glance into the future of virtual autopsy
    Gascho, Dominic
    FRONTIERS IN RADIOLOGY, 2024, 4
  • [48] Addressing CT metal artifacts using photon-counting detectors and one-step spectral CT image reconstruction
    Schmidt, Taly Gilat
    Sammut, Barbara A.
    Barber, Rina Foygel
    Pan, Xiaochuan
    Sidky, Emil Y.
    MEDICAL PHYSICS, 2022, 49 (05) : 3021 - 3040
  • [49] Quantitative Accuracy in Cardiac Studies with the GE Discovery RX PET/CT Scanner
    Spinks, T. J.
    Bastin, J. E.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2972 - 2976
  • [50] Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT
    Robert Hermans
    Lukas Boomgaert
    Lesley Cockmartin
    Joke Binst
    Rashèl De Stefanis
    Hilde Bosmans
    Insights into Imaging, 14