Technical note: Can photon-counting CT improve PET/CT's quantitative accuracy?

被引:1
|
作者
Hamill, James [1 ]
Birge, Noah [1 ]
O'Doherty, Jim [2 ,3 ]
Nye, Jonathon [4 ]
Elojeimy, Saeed [4 ]
机构
[1] Siemens Med Solut USA, 810 Innovat Dr Knoxville, Tennessee, IL 37923 USA
[2] Siemens Med Solut USA, CT R&D Collaborat, Malvern, PA USA
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC USA
[4] Med Univ South Carolina, Dept Radiol & Radiol Sci, Dept Nucl Med, Charleston, SC USA
关键词
attenuation correction; PET; photon-counting CT; ATTENUATION CORRECTION; INTRAVENOUS CONTRAST;
D O I
10.1002/mp.17299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundLinear attenuation coefficients (LACs) in positron emission tomography combined with computed tomography (PET/CT) are derived from CT scans that utilize energy-integrating detectors (EID-CT). These LACs are inaccurate when iodine contrast has been injected. Photon counting detector CT (PCD-CT) may be able to improve the accuracy.PurposeTo investigate whether PCD-CT can improve PET/CT quantitative accuracy.MethodsTwo experiments were performed: one with CT only and one that combined PET and CT. The first experiment used an electron density phantom whose inserts were imaged with EID-CT and PCD-CT. The inserts simulated normal human tissues, including bone and iodinated blood. In the case of PCD-CT, virtual-monoenergetic images at 190 keV were created. LACs were derived in each case and compared against known values. For inserts with iodine, more accurate LACs were expected with PCD-CT. The second experiment involved a custom PET phantom with various materials simulating human tissues (blood, iodinated blood, and bone) and 18F radioactivity. Data were first acquired with an EID-CT-based PET/CT system and then separately in a PCD-CT system without PET. PET images were reconstructed using LAC from EID-CT and PCD-CT. PET image values were compared against known activity values using recovery coefficients (RC).ResultsIn the first experiment, LAC based on EID-CT were in error by as much as 18%, whereas the corresponding PCD-CT based measurements were within 3%. In the second experiment, minimum, maximum, and mean RC were (96.1%, 115.4%, and 103.8%) for the EID-CT method, and (95.8%, 105.5%, and 101.0%) for the PCD-CT method. The consistency of PET images in body and head orientations was improved.ConclusionsPCD-CT can acquire the information needed for accurate LAC for PET reconstruction in a single spiral acquisition.
引用
收藏
页码:7206 / 7213
页数:8
相关论文
共 50 条
  • [21] Metal Artifact Reduction in Photon-Counting Detector CT Quantitative Evaluation of Artifact Reduction Techniques
    Skornitzke, Stephan
    Mergen, Victor
    Biederer, Juergen
    Alkadhi, Hatem
    Do, Thuy D.
    Stiller, Wolfram
    Frauenfelder, Thomas
    Kauczor, Hans-Ulrich
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2024, 59 (06) : 442 - 449
  • [22] Basic principles and clinical potential of photon-counting detector CT
    Flohr, Thomas
    Ulzheimer, Stefan
    Petersilka, Martin
    Schmidt, Bernhard
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2020, 3 (01) : 19 - 34
  • [23] Eigenbin compression for reducing photon-counting CT data size
    Schmidt, Taly Gilat
    Yin, Zhye
    Yao, Jingwu
    Fan, Jiahua
    MEDICAL PHYSICS, 2024, : 8751 - 8760
  • [24] Basic principles and clinical potential of photon-counting detector CT
    Thomas Flohr
    Stefan Ulzheimer
    Martin Petersilka
    Bernhard Schmidt
    Chinese Journal of Academic Radiology, 2020, 3 : 19 - 34
  • [25] Development of a multimodality sensor for spectral photon counting CT, standard CT and PET
    Persson, Andreas
    Cederwall, Bo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S72 - S74
  • [26] A methodology for incorporating a photon-counting CT system into routine clinical use
    Bache, Steven T.
    Samei, Ehsan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [27] Dental imaging in clinical photon-counting CT at a quarter of DVT dose
    Sawall, Stefan
    Maier, Joscha
    Sen, Sinan
    Gehrig, Holger
    Kim, Ti -Sun
    Schlemmer, Heinz -Peter
    Schoenberg, Stefan O.
    Kachelriess, Marc
    Ruetters, Maurice
    JOURNAL OF DENTISTRY, 2024, 142
  • [28] Imaging the pancreas with photon-counting CT - A review of normal pancreatic anatomy
    Brandt, Erik G. S.
    Mueller, Christoph F.
    Thomsen, Henrik
    Rodell, Anders B.
    Ibragimov, Bulat
    Andersen, Michael B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [29] Photon-counting normalized metal artifact reduction (NMAR) in diagnostic CT
    Byl, Achim
    Klein, Laura
    Sawall, Stefan
    Heinze, Sarah
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    MEDICAL PHYSICS, 2021, 48 (07) : 3572 - 3582
  • [30] Feasibility of the automated detection of colorectal polyps in photon-counting CT colonography
    Nappi, Janne J.
    Hironaka, Toru
    Wu, Dufan
    Yoshida, Stephen R.
    Gupta, Rajiv
    Tachibana, Rie
    Taguchi, Katsuyuki
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2023, 2023, 12469