High-Sensitivity Detection of Carbon Fiber-Reinforced Polymer Delamination Using a Novel Eddy Current Probe

被引:2
|
作者
Zhou, Yingni [1 ,2 ]
Ye, Bo [1 ,2 ]
Cao, Honggui [1 ,2 ]
Zou, Yangkun [2 ,3 ]
Zhu, Zhizhen [4 ]
Xing, Hongbin [1 ,2 ]
机构
[1] Kunming Univ Sci & Technol, Fac Informat Engn & Automat, Kunming 650500, Peoples R China
[2] Kunming Univ Sci & Technol, Yunnan Key Lab Intelligent Control & Applicat, Kunming 650500, Peoples R China
[3] Kunming Univ Sci & Technol, Fac Civil Aviat & Aeronaut, Kunming 650500, Peoples R China
[4] Chongqing Mil Representat Bur, Army Equipment Dept Kunming, Mil Representat Off 1, Kunming 650032, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 09期
关键词
non-destructive testing; eddy current testing; carbon fiber-reinforced polymer; delamination; high-sensitivity detection; COMPOSITE-MATERIALS; CFRP; SYSTEM; SIMULATION; PARAMETERS; COILS;
D O I
10.3390/app14093765
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The demand for non-destructive testing of carbon fiber-reinforced polymer (CFRP) is becoming increasingly pressing to ensure its safety and reliability across different fields of use. However, the complex structural characteristics and anisotropic bulk conductivity of CFRP make achieving high sensitivity in detecting internal defects such as delamination extremely challenging. To address this issue, a novel triple rectangular coil probe with high sensitivity developed for detecting delamination in CFRP is presented in this paper. A finite element model using COMSOL Multiphysics was developed for CFRP delamination eddy current testing with the designed probe. Based on this model, the probe parameters were determined through orthogonal experiments. By analyzing the eddy current distribution in CFRP samples, the scanning mode was defined. Following this, the detection voltage was evaluated for various delamination parameters, and the sensitivity of different probes was compared. Results indicate that, under the same excitation coil parameters, for a 5 mm delamination lateral dimension change, the single pancake and single rectangular coil probes exhibit sensitivities of 88.24% and 72.55%, respectively, compared with the designed probe. For a 0.5 mm delamination thickness change, their sensitivities are 49.04% and 56.69% of those of the designed probe. The designed probe meets the demand for high-sensitivity detection.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Enhancement of sensitivity to delamination in eddy current testing of carbon fiber composites by varying probe geometry
    Mizukami, Koichi
    bin Ibrahim, Ahmad Syukri
    Ogi, Keiji
    Matvieieva, Nataliia
    Kharabet, Ievgen
    Schulze, Martin
    Heuer, Henning
    COMPOSITE STRUCTURES, 2019, 226
  • [2] Testing of delamination in multidirectional carbon fiber reinforced polymer laminates using the vertical eddy current method
    Zeng, Zhiwei
    Tian, Qingze
    Wang, Handong
    Jiao, Shaoni
    Li, Jian
    COMPOSITE STRUCTURES, 2019, 208 : 314 - 321
  • [3] Damage Detection in Carbon Fiber-Reinforced Composite Structures Using Eddy Current Pot-Core Sensor
    Tytko, Grzegorz
    Rogala, Tomasz
    Katunin, Andrzej
    Yin, Wuliang
    IEEE ACCESS, 2024, 12 : 123609 - 123620
  • [4] Eddy Current Testing of Delamination in Carbon Fiber Reinforced Polymer (CFRP): A Finite Element Analysis
    Zeng, Zhiwei
    Jiao, Shaoni
    Du, Fei
    Sun, Lei
    Li, Jian
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2018, 29 (04) : 199 - 211
  • [5] Novel electromagnetic modeling approach of carbon fiber-reinforced polymer laminate for calculation of eddy currents and eddy current testing signals
    Cheng, Jun
    Ji, Hongli
    Qiu, Jinhao
    Takagi, Toshiyuki
    Uchimoto, Tetsuya
    Hu, Ning
    JOURNAL OF COMPOSITE MATERIALS, 2015, 49 (05) : 617 - 631
  • [6] High-sensitivity phase imaging eddy current magneto-optical system for carbon fiber reinforced polymers detection
    Ai J.-S.
    Zhou Q.
    Liang Y.-P.
    Feng C.-R.
    Long B.
    Bai L.-B.
    Wang Y.-G.
    Ren C.
    Journal of Electronic Science and Technology, 2023, 21 (04)
  • [7] Contactless high-speed eddy current inspection of unidirectional carbon fiber reinforced polymer
    Machado, Miguel A.
    Antin, Kim-Niklas
    Rosado, Luis S.
    Vilaca, Pedro
    Santos, Telmo G.
    COMPOSITES PART B-ENGINEERING, 2019, 168 : 226 - 235
  • [8] NONDESTRUCTIVE INSPECTION OF CARBON FIBER-REINFORCED PLASTICS USING EDDY-CURRENT METHODS
    DEGOEJE, MP
    WAPENAAR, KED
    COMPOSITES, 1992, 23 (03): : 147 - 157
  • [9] Reconstruction of cracks in a carbon fiber-reinforced polymer laminate plate from signals of eddy current testing
    Du, Yali
    Li, Xudong
    Xie, Shejuan
    Yang, Shiyou
    Chen, Zhenmao
    JOURNAL OF COMPOSITE MATERIALS, 2020, 54 (24) : 3527 - 3536
  • [10] Detection of delamination defects inside carbon fiber reinforced plastic laminates by measuring eddy-current loss
    Wang, Teng
    Wu, Dehui
    Chen, Wenxiong
    Yang, Jiaxin
    COMPOSITE STRUCTURES, 2021, 268