Study on interior beam-column joint sub-assemblage under bi-directional loading using finite element analysis

被引:0
|
作者
Nagargoje, Shashikant Mahadev [1 ]
Mahajan, Milinda Ashok [1 ]
机构
[1] Savitribai Phule Pune Univ, Dept Technol, Pune, India
关键词
Beam-column joint; Interior joint; Bi-directional loading; Joint detailed with tie reinforcement; Reinforced concrete; Finite element analysis; MODEL; PARAMETERS;
D O I
10.1108/WJE-03-2024-0129
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
PurposeThe purpose of this paper is to study the shearing performance under bi-directional loading of an interior beam-column joint (BCJ) sub-assemblage using the finite element analysis (FEA) tool (midas fea), validated in this research.Design/methodology/approachThe BCJ can be defined as an essential part of the column that transfers the forces at the ends of the members connected to it. The members of the rigid jointed plane frame resist external forces by developing twisting moment, bending moment, axial force and shear force in the frame members. On the type of joints, the response to the action of lateral loads depends on reinforced concrete (RC) framed structures. The joint is considered rigid if the angle between the members remains unchanged during the structural deformation. This work examined the shear deformation, load displacement and strength of a non-seismically detailed internal concentric RC joint using non-linear FEA. The bi-directional loading imposes the oblique compression zone on one joint corner. This joint core's oblique compression strut mechanism differs significantly from that under unidirectional loading. The numerical results are compared with experimental results in this study, with the data published in the literature.FindingsNumerical analysis results show that, in the comparative study of numerical and experimental values, the FEA tool predicts the behaviour of the RC BCJ well. The discrepancy between the experimental and numerical results amounts to 6 to 12% end displacement of the beam, 7% resultant joint shear force, 4.23% column bar strain and 0.70% hoop strain.Originality/valueThe current code of practice describes the joint sub-assemblage behaviour along the single axis individually. In the non-orthogonal system, the superposition of the two axes for joint space results in overlapping the stresses and, hence, the formation of the oblique strut. This may result in a reduction in the joint capacity under bi-directional loading. The behaviour must be explored in depth, and an attempt is made for further exploration.
引用
收藏
页数:10
相关论文
共 36 条
  • [1] Development of upgradation schemes for gravity load designed beam-column sub-assemblage under cyclic loading
    Sasmal, Saptarshi
    Lakshmanan, N.
    Ramanjaneyulu, K.
    Iyer, Nagesh R.
    Novak, Balthasar
    Srinivas, V.
    Kumar, K. Saravana
    Roehm, Constanze
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (08) : 3625 - 3638
  • [2] Bi-directional interaction of joint shear strength in non-seismically designed corner RC beam-column connections under seismic loading
    Najafgholipour, Mohammad Amir
    Rad, Negin Ahmadi
    Sharma, Akanshu
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2025, 24 (01) : 135 - 153
  • [3] Experimental and finite element analysis of cold formed steel beam-column joint
    Hanisha, Cherukuri Sri Sai
    Kishore, I. Siva
    MATERIALS TODAY-PROCEEDINGS, 2020, 33 : 480 - 483
  • [4] Static Behavior of UHPC Corner Beam-Column Joint Under Constant Axial and Increasing Bi-Directional Bending Loads
    Nadir, Wissam
    Ali, Ammar Yasir
    Jawdhari, Akram
    Kadhim, Majid M. A.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (07) : 1291 - 1308
  • [5] Experimental and finite element analysis of modular prefabricated composite beam-column interior joints
    Wu, Chenglong
    Zhou, Yang
    Liu, Jiming
    Mou, Ben
    Shi, Jiyuan
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [6] Finite element analysis of precast concrete beam-column joint based on bolt connection
    Xu, Jingbin
    Li, Hao
    Zhang, Yu
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2024, 33 (13)
  • [7] Finite Element Analysis of Reinforced Concrete Beam-Column Connections with Governing Joint Shear Failure Mode
    Najafgholipour, M. A.
    Dehghan, S. M.
    Dooshabi, Amin
    Niroomandi, Arsalan
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2017, 14 (07): : 1200 - 1225
  • [8] Exterior beam-column joint study with non-conventional reinforcement detailing using mechanical anchorage under reversal loading
    Rajagopal, S.
    Prabavathy, S.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2014, 39 (05): : 1185 - 1200
  • [9] Exterior beam-column joint study with non-conventional reinforcement detailing using mechanical anchorage under reversal loading
    S RAJAGOPAL
    S PRABAVATHY
    Sadhana, 2014, 39 : 1185 - 1200
  • [10] Strength and stress analysis of steel beam-column connections using finite element method
    Chen, H
    Shi, YJ
    Wang, YQ
    Li, ZF
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 285 - 291