Push-out performance of stud/channel steel connectors in UHPC for new precast concrete beam-slab connections

被引:0
|
作者
Zhang, Jianxin [1 ,2 ]
Zhang, Tingwei [1 ]
Yuan, Weitao [1 ]
机构
[1] Hebei Univ Technol, Sch Civil & Transportat Engn, 5340 Xiping Rd, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Civil Engn Technol Res Ctr Hebei Prov, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
PC beam-Slab connection; stud connectors; channel steel connectors; shear strength; push-out test; STUD SHEAR CONNECTORS; COLUMN JOINT; BEHAVIOR; CHANNEL; DAMAGE; CAPACITY; TESTS;
D O I
10.1177/13694332241254605
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
At present, the connection between the beams and slabs adopting composite layers is cast on-site, which is laborious and time-consuming. In this study, a new type of precast concrete (PC) beam and PC slab connection, which was connected by stud/channel steel connectors, was proposed to enhance the efficiency of prefabricated construction. Push-out tests were carried out on 5 PC beam-slab specimens connected with studs and 3 PC beam-slab specimens with channel steel connectors. The test variables were the connecting methods of beam-slab, the connector reinforcement ratio and the connecting width between two slabs. The failure process, load and slip of the beam-slab connection were recorded. Then, the slip behavior, shear capacity and shear stiffness of the PC beam-slab connection were analyzed. The results showed that the new type of PC beam-slab connection proposed in this study was an effective form for transferring force between the beam and slabs. Based on the push-out test results, the shear mechanism of connectors was analyzed and the calculation formulas for shear strength of stud/channel steel connectors were put forward. The calculated values obtained from the proposed formula demonstrated a strong correlation with the test results, providing an accurate measurement of shear strength of the new type of PC beam-slab connection. This study offers a reference for realizing the fast-full assembly construction of PC frame.
引用
收藏
页码:1901 / 1921
页数:21
相关论文
共 50 条
  • [41] Finite Element Analysis of Precast Concrete Deck-Steel Beam-Connection Concrete (PCSC) Connectors Using Ultra-High Performance Concrete (UHPC) for the Composite Beam
    Guo, Jincen
    Zhou, Zhixiang
    Zou, Yang
    Zhang, Zhongya
    Jiang, Jinlong
    BUILDINGS, 2022, 12 (09)
  • [42] Push-out test on the one end welded corrugated-strip connectors in steel-concrete-steel sandwich structure
    Yousefi, Mehdi
    Ghalehnovi, Mansour
    STEEL AND COMPOSITE STRUCTURES, 2017, 24 (01): : 23 - 35
  • [43] Analysis Method of Bearing Capacity of Stud Connector in Steel-concrete Composite Structures Under Push-out Failure
    Pu Q.
    Xie H.
    Fan S.
    Wang W.
    Liu J.
    Gou H.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2019, 51 (01): : 89 - 95
  • [44] Fatigue performance of stud shear connectors in steel-concrete composite beam with initial damage
    Lu, Kaiwei
    Du, Linpu
    Xu, Qizhi
    Yao, Yiming
    Wang, Jingquan
    ENGINEERING STRUCTURES, 2023, 276
  • [45] Shear Performance and Optimization Design of Beam-Slab Connector of Prefabricated Steel–Concrete Composite Structures
    Shaochun Ma
    Long Chen
    Peng Bao
    Dongtao Wang
    International Journal of Civil Engineering, 2022, 20 : 1277 - 1290
  • [46] Effects of stud aspect ratio and cover thickness on push-out performance of thin full-depth precast UHPC slabs with grouped short studs: Experimental evaluation and design considerations
    Fang, Shu
    Zhang, Shufeng
    Cao, Zhipeng
    Zhao, Guifeng
    Fang, Zhuangcheng
    Ma, Yuhong
    Jiang, Haibo
    JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [47] Push-out test on shear behavior of joint structure between corrugated steel web and concrete lower slab
    Wang, Sihao
    Liu, Yuqing
    He, Jun
    Li, Chuanxi
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 374 - 380
  • [48] Experimental analysis of rectangular shaped sleeve connectors for composite wood-steel-concrete floors: Push-out tests
    Faggiano, B.
    Marzo, A.
    Mazzolani, F. M.
    Caiado, L.
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 531 - +
  • [49] ANALYSIS OF RECTANGULAR-SHAPED COLLAR CONNECTORS FOR COMPOSITE TIMBER-STEEL-CONCRETE FLOORS: PUSH-OUT TESTS
    Faggiano, Beatrice
    Marzo, Anna
    Mazzolani, Federico M.
    Calado, Luis M.
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2009, 15 (01) : 47 - 58
  • [50] Bearing capacity of embedded channel-shaped steel connections at precast concrete beam end
    Guo, Xiaonong
    Gao, Shuyu
    Wang, Li
    Tien Ngoc Bui
    ENGINEERING STRUCTURES, 2018, 175 : 177 - 190