Optimal PMU Placement to Enhance Observability in Transmission Networks Using ILP and Degree of Centrality

被引:2
作者
Ahmed, Muhammad Musadiq [1 ]
Amjad, Muhammad [2 ]
Qureshi, Muhammad Ali [3 ]
Khan, Muhammad Omer [4 ]
Haider, Zunaib Maqsood [1 ]
机构
[1] Islamia Univ Bahawalpur, Dept Elect Engn, Bahawalpur 63100, Punjab, Pakistan
[2] Islamia Univ Bahawalpur, Dept Elect Engn, Bahawalpur 63100, Punjab, Pakistan
[3] Islamia Univ Bahawalpur, Dept Informat & Commun Engn, Bahawalpur 63100, Punjab, Pakistan
[4] Riphah Int Univ, Dept Elect Engn & Technol, Faisalabad 37000, Punjab, Pakistan
关键词
phasor measurement unit (PMU); optimal PMU placement (OPP); integer linear programming (ILP); bus observability index (BOI); sum of redundancy index (SORI); PHASOR MEASUREMENT UNITS; SYSTEM OBSERVABILITY; ALGORITHM; OPTIMIZATION; LOCATION;
D O I
10.3390/en17092140
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The optimal PMU placement problem is placing the minimum number of PMUs in the network to ensure complete network observability. It is an NP-complete optimization problem. PMU placement based on cost and critical nodes is solved separately in the literature. This paper proposes a novel approach, a degree of centrality in the objective function, to combine the effect of both strategies to place PMUs in the power network optimally. The contingency analysis and the effect of zero-injection buses are solved to ensure the reliability of network monitoring and attain a minimum number of PMUs. Integer linear programming is used on the IEEE 7-bus, IEEE 14-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus, and IEEE 118-bus systems to solve this problem. The results are evaluated based on two performance measures: the bus observability index (BOI) and the sum of redundancy index (SORI). On comparison, it is found that the proposed methodology has significantly improved results, i.e., a reduced number of PMUs and increased network overall observability (SORI). This methodology is more practical for implementation as it focuses on critical nodes. Along with improvement in the results, the limitations of existing indices are also discussed for future work.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Optimal PMU Placement for Complete System Observability and Fault Observability Using Graph Theory
    Ghosh, Pronob K.
    Tahabilder, Anik
    2017 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2017,
  • [2] Optimal PMU placement for power system observability using BICA, considering measurement redundancy
    Mahari, Arash
    Seyedi, Heresh
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 103 : 78 - 85
  • [3] An optimal PMU placement technique for power system observability
    Roy, B. K. Saha
    Sinha, A. K.
    Pradhan, A. K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 71 - 77
  • [4] Optimal multistage scheduling of PMU placement: An ILP approach
    Dua, Devesh
    Dambhare, Sanjay
    Gajbhiye, Rajeev Kumar
    Soman, S. A.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1812 - 1820
  • [5] Adaptive Optimal PMU Placement Based on Empirical Observability Gramian
    Qi, Junjian
    Sun, Kai
    Kang, Wei
    IFAC PAPERSONLINE, 2016, 49 (18): : 482 - 487
  • [6] Optimal PMU placement for modeling power grid observability with mathematical programming methods
    Almunif, Anas
    Fan, Lingling
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (02)
  • [7] Optimal PMU Placement for Distribution Networks
    Mabaning, Abdul Aziz G.
    Orillaza, Jordan Rel C.
    von Meier, Alexandra
    2017 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), 2017, : 577 - 582
  • [8] Research on Optimal D-PMU Placement Technology to Improve the Observability of Smart Distribution Networks
    Kong, Xiangyu
    Yuan, Xiaoxiao
    Wang, Yuting
    Xu, Yong
    Yu, Li
    ENERGIES, 2019, 12 (22)
  • [9] Observability Analysis and Optimal Placement of PMU using Differential Evolution Algorithm
    Venkateswaran, V. Balaji
    Kala, V. Subbu Chithira
    2012 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ELECTRICAL ENGINEERING AND ENERGY MANAGEMENT (ICETEEEM - 2012), 2012, : 205 - 209
  • [10] System Observability Indices for Optimal Placement of PMU Measurements
    Powalko, M.
    Orths, A. G.
    Abildgaard, H.
    Eriksen, P. B.
    Rudion, K.
    Golub, I. I.
    Voropai, N. I.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,