Impedance threshold device as a countermeasure for spaceflight associated neuro-ocular syndrome (SANS): Mitigating mechanisms in proposed pathophysiology

被引:1
作者
Masood, Mohammed Tayyib [1 ]
Wang, Jen-Wei [1 ]
Zoumi, Eleni Angeliki [2 ]
Jain, Kinshuk [3 ]
Suh, Alex [4 ]
Ong, Joshua [5 ]
Waisberg, Ethan [6 ]
Masalkhi, Mouayad [7 ]
Lee, Andrew G. [8 ,9 ,10 ,11 ,12 ,13 ,14 ,15 ]
机构
[1] Newcastle Univ, Med Sch, Framlington, England
[2] Univ Exeter, Med Sch, Exeter, England
[3] Leeds Sch Med, Leeds, England
[4] Tulane Univ, Sch Med, New Orleans, LA USA
[5] Univ Michigan, Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Ann Arbor, MI USA
[6] Univ Cambridge, Dept Ophthalmol, Cambridge, England
[7] Univ Coll Dublin, Sch Med, Dublin, Ireland
[8] Baylor Coll Med, Ctr Space Med, Houston, TX USA
[9] Houston Methodist Hosp, Blanton Eye Inst, Dept Ophthalmol, 6560 Fannin St 450, Houston, TX 77030 USA
[10] Houston Methodist Hosp, Houston Methodist Res Inst, Houston, TX USA
[11] Weill Cornell Med, Dept Ophthalmol Neurol & Neurosurg, New York, NY USA
[12] Univ Texas Med Branch, Dept Ophthalmol, Galveston, TX USA
[13] Univ Texas MD Anderson Canc Ctr, Houston, TX USA
[14] Texas A&M Coll Med, Bryan, TX USA
[15] Univ Iowa Hosp & Clin, Dept Ophthalmol, Iowa City, IA USA
关键词
Impedance threshold device; Spaceflight associated neuro-ocular syndrome; Space medicine; Microgravity; HEAD-DOWN TILT; DECOMPRESSION CARDIOPULMONARY-RESUSCITATION; OPTIC DISC EDEMA; INTRATHORACIC PRESSURES; OCULAR CHANGES; THIGH CUFFS; NERVE HEAD; MICROGRAVITY; QUANTIFICATION; METAANALYSIS;
D O I
10.1016/j.lssr.2024.06.002
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Long-duration spaceflight (LDSF) is associated with unique hazards and linked with numerous human health risks including Spaceflight Associated Neuro-ocular Syndrome (SANS). The proposed mechanisms for SANS include microgravity induced cephalad fluid shift and increased Intracranial Pressure (ICP). SANS is a disorder seen only after LDSF and has no direct terrestrial pathologic counterpart as the zero G environment cannot be completely replicated on Earth. Head-down tilt, bed rest studies however have been used as a terrestrial analog and produce the cephalad fluid shift. Some proposed countermeasures for SANS include vasoconstrictive thigh cuffs and lower body negative pressure. Another potential researched countermeasure is the impedance threshold device (ITD) which can reduce ICP. We review the mechanisms of the ITD and its potential use as a countermeasure for SANS.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 70 条
[1]  
Alperin N, 2005, ACT NEUR S, V95, P129
[2]   Lower body negative pressure reduces jugular and portal vein volumes and counteracts the elevation of middle cerebral vein velocity during long-duration spaceflight [J].
Arbeille, P. ;
Zuj, K. A. ;
Macias, B. R. ;
Ebert, D. J. ;
Laurie, S. S. ;
Sargsyan, A. E. ;
Martin, D. S. ;
Lee, S. M. C. ;
Dulchavsky, S. A. ;
Stenger, M. B. ;
Hargens, A. R. .
JOURNAL OF APPLIED PHYSIOLOGY, 2021, 131 (03) :1080-1087
[3]   Influences of thigh cuffs on the cardiovascular system during 7-day head-down bed rest [J].
Arbeille, P ;
Herault, S ;
Fomina, G ;
Roumy, J ;
Alferova, I ;
Gharib, C .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2168-2176
[4]   The Mobile Lower Body Negative Pressure Gravity Suit for Long-Duration Spaceflight [J].
Ashari, Neeki ;
Hargens, Alan R. .
FRONTIERS IN PHYSIOLOGY, 2020, 11
[5]   A Trial of an Impedance Threshold Device in Out-of-Hospital Cardiac Arrest [J].
Aufderheide, Tom P. ;
Nichol, Graham ;
Rea, Thomas D. ;
Brown, Siobhan P. ;
Leroux, Brian G. ;
Pepe, Paul E. ;
Kudenchuk, Peter J. ;
Christenson, Jim ;
Daya, Mohamud R. ;
Dorian, Paul ;
Callaway, Clifton W. ;
Idris, Ahamed H. ;
Andrusiek, Douglas ;
Stephens, Shannon W. ;
Hostler, David ;
Davis, Daniel P. ;
Dunford, James V. ;
Pirrallo, Ronald G. ;
Stiell, Ian G. ;
Clement, Catherine M. ;
Craig, Alan ;
Van Ottingham, Lois ;
Schmidt, Terri A. ;
Wang, Henry E. ;
Weisfeldt, Myron L. ;
Ornato, Joseph P. ;
Sopko, George .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (09) :798-806
[6]   Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest [J].
Aufderheide, TP ;
Pirrallo, RG ;
Provo, TA ;
Lurie, KG .
CRITICAL CARE MEDICINE, 2005, 33 (04) :734-740
[7]   Thigh Cuffs as a Countermeasure for Ocular Changes in Simulated Weightlessness [J].
Balasubramanian, Siva ;
Tepelus, Tudor ;
Stenger, Michael B. ;
Lee, Stuart M. C. ;
Laurie, Steven S. ;
Liu, John H. K. ;
Feiveson, Alan H. ;
Sadda, SriniVas R. ;
Huang, Alex S. ;
Macias, Brandon R. .
OPHTHALMOLOGY, 2018, 125 (03) :459-460
[8]   The effect of prolonged spaceflight on cerebrospinal fluid and perivascular spaces of astronauts and cosmonauts [J].
Barisano, Giuseppe ;
Sepehrband, Farshid ;
Collins, Heather R. ;
Jillings, Steven ;
Jeurissen, Ben ;
Taylor, James A. ;
Schoenmaekers, Catho ;
De laet, Chloe ;
Rukavishnikov, Ilya ;
Nosikova, Inna ;
Litvinova, Liudmila ;
Rumshiskaya, Alena ;
Annen, Jitka ;
Sijbers, Jan ;
Laureys, Steven ;
Van Ombergen, Angelique ;
Petrovichev, Victor ;
Sinitsyn, Valentin ;
Pechenkova, Ekaterina ;
Grishin, Alexey ;
zu Eulenburg, Peter ;
Lawl, Meng ;
Sunaert, Stefan ;
Parizel, Paul M. ;
Tomilovskaya, Elena ;
Roberts, Donna R. ;
Wuyts, Floris L. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2022, 119 (17)
[9]   Impact of impedance threshold devices on cardiopulmonary resuscitation: A systematic review and meta-analysis of randomized controlled studies [J].
Cabrini, Luca ;
Beccaria, Paolo ;
Landoni, Giovanni ;
Biondi-Zoccai, Giuseppe G. L. ;
Sheiban, Imad ;
Cristofolini, Marta ;
Fochi, Oliviero ;
Maj, Giulia ;
Zangrillo, Alberto .
CRITICAL CARE MEDICINE, 2008, 36 (05) :1625-1632
[10]  
Convertino Victor A, 2004, Crit Care Med, V32, pS381, DOI 10.1097/01.CCM.0000134348.69165.15