Validation study of a Kinect based body imaging system

被引:12
作者
Braganca, Sara [1 ]
Arezes, Pedro [1 ]
Carvalho, Miguel [2 ]
Ashdown, Susan P. [3 ]
Xu, Bugao [4 ]
Castellucci, Ignacio [5 ]
机构
[1] Univ Minho, Dept Prod & Syst, Guimaraes, Portugal
[2] Univ Minho, Dept Text Engn, Guimaraes, Portugal
[3] Cornell Univ, Dept Fiber Sci & Apparel Design, Ithaca, NY USA
[4] Univ Texas Austin, Dept Text & Apparel, Austin, TX 78712 USA
[5] Univ Valparaiso, Fac Med, Escuela Kinesiol, Valparaiso, Chile
来源
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION | 2017年 / 57卷 / 01期
关键词
Traditional anthropometry; 3D body scanners; Kinect; reliability; precision; ANTHROPOMETRY; SCANNER; ACCURACY;
D O I
10.3233/WOR-172532
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BACKGROUND: Understanding the reliability and precision of the data obtained using three-dimensional body scanners is very important if it is intended to replace the traditional data collection methods. If the collection of anthropometric data with three-dimensional body scanners is a fast and reliable process that produces precise data at a low price, it could be used for numerous applications worldwide. Many studies have addressed data collected by white light and laser based scanners. OBJECTIVE: This study provides a comparative analysis between the anthropometric data collected using a Kinect body imaging system with the data collected using traditional manual methods. Moreover, a comparison is also made between the results obtained in this study and the results of previous studies of different types of body scanners. METHODS: The Mean Absolute Difference was calculated and all the values were compared to the maximum allowable error defined in ISO 20685. Additionally, an analysis of the significant differences between the two acquisition methods was also applied to a physical mannequin, to understand how the body movement and body stance variation in human participants impacts the results obtained. RESULTS: There are few body measurements that are close to this restricted allowable error. The results were better when the mannequin was measured. Although they were still above the ISO 20685 limit, they were much closer than the results obtained for human participants. CONCLUSION: The main cause of the differences between the two methods is the time required for the 3D system to acquire the data. The involuntary body sway of human participants is more difficult to control when the time span is too long.
引用
收藏
页码:9 / 21
页数:13
相关论文
共 37 条
[1]  
[Anonymous], 1996, HUM BOD MEAS TECHN D
[2]  
[Anonymous], 2010, 20685 ISO
[3]   Anthropometric study of Portuguese workers [J].
Barroso, MP ;
Arezes, PM ;
da Costa, LG ;
Miguel, AS .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2005, 35 (05) :401-410
[4]   Anthropometry of Algerian elderly [J].
Bouabdallah, L. .
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 41 :5415-5416
[5]   A comparison of women's sizing by 3D electronic scanning and traditional anthropometry [J].
Bougourd, JP ;
Dekker, L ;
Ross, PG ;
Ward, JP .
JOURNAL OF THE TEXTILE INSTITUTE, 2000, 91 (02) :163-173
[6]  
Bradshaw B, 1999, STUDIES REGULAT, P3
[7]   RELIABILITY AND REPEATABILITY OF 3-D BODY SCANNER (LASS) MEASUREMENTS COMPARED TO ANTHROPOMETRY [J].
BROOKEWAVELL, K ;
JONES, PRM ;
WEST, GM .
ANNALS OF HUMAN BIOLOGY, 1994, 21 (06) :571-577
[8]   3D body scan analysis of dimensional change in lower body measurements for active body positions [J].
Choi, Sunyoon ;
Ashdown, Susan P. .
TEXTILE RESEARCH JOURNAL, 2011, 81 (01) :81-93
[9]   Reducing movement artifacts in whole body scanning [J].
Daanen, HAM ;
Brunsman, MA ;
Robinette, KM .
INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN 3-D DIGITAL IMAGING AND MODELING, PROCEEDINGS, 1997, :262-265
[10]   Whole body scanners [J].
Daanen, HAM ;
van de Water, GJ .
DISPLAYS, 1998, 19 (03) :111-120