Comparison of Biomechanical Behaviors of Different Designs and Configurations of Titanium and Zirconium Dental Implants With Finite Elements Analysis in Anterior Maxilla

被引:0
作者
Izgi, Eda [1 ]
Simsek, Mehmet Baris [2 ]
机构
[1] Kutahya Hlth Sci Univ, Kutahya, Turkiye
[2] Gazi Univ, Ankara, Turkiye
关键词
dental implants; titanium; zirconia; finite element analysis; anterior maxilla; STRESS-DISTRIBUTION; SUPPORTED PROSTHESES; BONE QUALITY; DIAMETER; LENGTH; NUMBER; STRAIN; FORCE;
D O I
10.1563/aaid-joi-D-24-00011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Finite element analysis assists in the understanding of the biomechanical behavior of implants with different designs and material characteristics. Through this analysis, this study aimed to compare the biomechanical behaviors of different designs and configurations of titanium (tapered or cylindric) and zirconia dental implants in the edentulous anterior maxilla. Three-dimensional models of the edentulous maxilla, dental implants, and prosthetic structures were modeled, and different loading conditions were applied to simulate realistic conditions. A total of 6 different models were evaluated: the model (M1) in which tapered implants were located bilaterally in the central canine, the model (M2) in which tapered implants were located bilaterally in the lateral canine, the model (M3) in which cylindric implants were located bilaterally in the central canine, the model (M4) in which cylindric implants were located bilaterally in the lateral canine, the model (M5) in which zirconia implants were located bilaterally in the central canine, and the model (M6) in which zirconia implants were located bilaterally in the lateral canine. Maximum tensile and compressive stress values were recorded at M4 under vertical loading and at M6 under oblique loading, whereas minimum stress values were recorded at M1 under all loading conditions. Maximum von Mises stress values under vertical and oblique loading conditions were observed at M3 and M4, while the minimum stress was observed at M1 and M2. In conclusion, zirconia implants may present a biomechanically convenient and esthetic alternative treatment option in edentulous anterior maxilla rehabilitation compared with tapered and cylindric implants.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 47 条
[1]  
Akca K, 2001, Implant Dent, V10, P238
[2]   Biomechanics Studies in Dentistry: Bioengineering Applied in Oral Implantology [J].
Assuncao, Wirley Goncalves ;
Ricardo Barao, Valentim Adelino ;
Tabala, Lucas Fernando ;
Gomes, Erica Alves ;
Delben, Juliana Aparecida ;
dos Santos, Paulo Henrique .
JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) :1173-1177
[3]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[4]  
Bahuguna Rohit, 2013, Natl J Maxillofac Surg, V4, P46, DOI 10.4103/0975-5950.117882
[5]   Finite Element Analysis of Stress Distribution with Splinted and Nonsplinted Maxillary Anterior Fixed Prostheses Supported by Zirconia or Titanium Implants [J].
Bal, Bilge Turhan ;
Caglar, Alper ;
Aydin, Cemal ;
Yilmaz, Handan ;
Bankoglu, Merve ;
Eser, Atilim .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) :E27-E38
[6]   Effect of different biocompatible implant materials on the mechanical stability of dental implants under excessive oblique load [J].
Bataineh, Khaled ;
Al Janaideh, Mohammad .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) :1206-1217
[7]   Number and localization of the implants for the fixed prosthetic reconstructions: On the strain in the anterior maxillary region [J].
Bolukbasi, Nilufer ;
Yeniyol, Sinem .
MEDICAL ENGINEERING & PHYSICS, 2015, 37 (04) :431-445
[8]   Biomechanical study of mandible bone supporting a four-implant retained bridge Finite element analysis of the influence of bone anisotropy and foodstuff position [J].
Bonnet, A. S. ;
Postaire, M. ;
Lipinski, P. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) :806-815
[9]   Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region [J].
Borie, Eduardo ;
Orsi, Iara Augusta ;
Noritomi, Pedro Yoshito ;
Kemmoku, Daniel Takanori .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (01) :101-110
[10]  
Çaglar A, 2010, INT J ORAL MAX IMPL, V25, P95