An automation of Monte Carlo workflow for dosimetry study of an Elekta LINAC delivery system in radiotherapy

被引:0
|
作者
Tseng, Wenchih [1 ]
Furutani, Keith [2 ]
Beltran, Chris [2 ]
Lu, Bo [2 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
[2] Mayo Clin Florida, Dept Radiat Oncol, Jacksonville, FL 32224 USA
来源
TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY | 2024年 / 31卷
关键词
Monte Carlo simulation; Automated workflow; EGSnrc; Elekta Linac; IMRT/VMAT; Graphical user interface; EGSNRC; BEAM; SIMULATION; GEANT4; CODE;
D O I
10.1016/j.tipsro.2024.100257
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aims to automate the Monte Carlo (MC) workflow utilized for radiotherapy dosimetry, focusing on an Elekta LINAC delivery system. It addresses the challenge of integrating MC simulations into routine clinical practice, making this accurate yet complex method more accessible and efficient for radiotherapy dosimetry. Methods and Materials: We developed a user-friendly software featuring a graphical user interface (GUI) that integrates EGSnrc for MC simulations. The software streamlines the process from retrieving Digital Imaging and Communications in Medicine (DICOM) data to executing dose calculations and comparing dose distributions. To validate our proposed tool, we compared its computed doses for IMRT and VMAT plans from the Pinnacle TPS for an Elekta Versa HD linear accelerator against MC simulation results. This comparison utilized our in-house software and GUI as the tool, covering various treatment sites and prescriptions. Results: The automated MC workflow demonstrated high accuracy in dose calculations and streamlined integration with clinical workflows. The comparison between the MC-simulated and TPS-calculated doses revealed excellent agreement, highlighting the reliability of MC for independent dose verification in complex treatment scenarios. Conclusions: The automated MC workflow developed represents a substantial improvement in the practicality and efficiency of MC simulations in radiotherapy. This advancement not only simplifies the dosimetry process but also ensures high accuracy, establishing it as a valuable tool for routine patient-specific quality assurance and the development of specialized treatment procedures.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Monte Carlo dosimetry for the Papillon P50 contact radiotherapy and IORT device
    Carver, Antony
    Gately, Alan
    Clements, Richard
    Nahum, Alan
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 367 - 369
  • [22] Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques
    Tzung-Chi Huang
    Ji-An Liang
    Thomas Dilling
    Tung-Hsin Wu
    Geoffrey Zhang
    Radiation Oncology, 5
  • [23] PENSSART, a new Monte Carlo system for quality control in radiotherapy
    Le Loirec, C.
    Garcia-Hernandez, J. C.
    Bonniaud, G.
    Guerin, L.
    Batalla, A.
    Poumarede, B.
    Lazaro, D.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [24] Mucosal dosimetry on unflattened photon beams: a Monte Carlo phantom study
    Chow, James C. L.
    Owrangi, Amir M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (01):
  • [25] DNA Dosimetry with Gold Nanoparticle Irradiated by Proton Beams: A Monte Carlo Study on Dose Enhancement
    Huynh, Ngoc Han
    Chow, James C. L.
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [26] Gel dosimetry measurements and Monte Carlo modeling for external radiotherapy photon beams comparison with a treatment planning system dose distribution
    Valente, M.
    Aon, E.
    Brunetto, A.
    Castellano, G.
    Gallivanone, F.
    Gambarini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 497 - 501
  • [27] A Monte Carlo study to evaluate and optimise the angular dependence of the Octa-A 2D silicon array detector used for dosimetry in stereotactic radiotherapy
    Filipev, Ilia
    Biasi, Giordano
    Poder, Joel
    Lerch, Michael
    Petasecca, Marco
    Guatelli, Susanna
    Kron, Tomas
    Rosenfeld, Anatoly
    RADIATION MEASUREMENTS, 2023, 166
  • [28] Depth dependence of electron backscatter: An energy spectral and dosimetry study using Monte Carlo simulation
    Chow, James C. L.
    Owrangi, Amir M.
    MEDICAL PHYSICS, 2009, 36 (02) : 594 - 601
  • [29] Monte Carlo study on optimal breast voxel resolution for dosimetry estimates in digital breast tomosynthesis
    Fedon, Christian
    Rabin, Carolina
    Caballo, Marco
    Diaz, Oliver
    Garcia, Eloy
    Rodriguez-Ruiz, Alejandro
    Gonzalez-Sprinberg, Gabriel A.
    Sechopouloshs, Ioannis
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01)
  • [30] ANALYTICAL AND MONTE CARLO SIMULATION STUDY OF THE INFLUENCE OF STRONG MAGNETIC FIELDS ON THE PATH OF ELECTRONS WITH ENERGY TYPICAL OF MRI-LINAC RADIOTHERAPY
    Gayol, A.
    Valente, M.
    ANALES AFA, 2022, 33 (01): : 6 - 11