A Fluorescent Lateral Flow Immunoassay for the Detection of Skeletal Muscle Troponin I in Serum for Muscle Injury Monitoring at the Point of Care

被引:0
|
作者
Tang, Deding [1 ,2 ,3 ]
Wu, Shuang [1 ,2 ]
Kong, Mengqi [1 ,2 ,4 ]
Liu, Zhaonan [1 ,2 ,4 ]
Li, Zonghao [1 ,2 ,4 ]
Han, Ying [5 ]
Gong, Yan [5 ]
Hu, Jie [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Key Lab Biomed Informat Engn, Minist Educ, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Bioinspired Engn & Biomech Ctr BEBC, Xian 710049, Peoples R China
[3] Maanshan Teachers Coll, Publ Teaching Dept, Maanshan 243041, Peoples R China
[4] Suzhou Diyinan Biotech Co, Suzhou 215129, Peoples R China
[5] Suzhou Univ Sci & Technol, Sch Chem & Life Sci, Suzhou 215009, Peoples R China
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 08期
关键词
lateral flow immunoassay; sports medicine; exercise-induced muscle injury; point-of-care testing; ASSAY;
D O I
10.3390/bios14080381
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exercise-induced muscle injury is one of the most common types of sports injuries. Skeletal muscle troponin I (skTnI) serves as an ideal biomarker in assessing such injuries, facilitating timely detection and evaluation. In this study, we develop a fluorescent sandwich lateral flow immunoassay (LFIA) combined with a desktop analyzer for rapid detection of skTnI. Through optimizing the reaction system, the assay achieves a satisfying detection performance, reaching a limit of detection (LOD) of 0.5 ng/mL with a turnaround time of 15 min. The proposed detection platform offers portability, ease of use, and high sensitivity, which facilitates the monitoring of exercise-induced muscle injuries at the point of care. This feature is particularly advantageous for end users, enabling timely detection of sports-related injuries and ultimately enhancing prognosis and sports life.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] FLUORESCENCE TITRATION AND FLUORESCENCE STOPPED-FLOW STUDIES ON SKELETAL-MUSCLE TROPONIN LABELED WITH FLUORESCENT REAGENT
    IIO, T
    KONDO, H
    JOURNAL OF BIOCHEMISTRY, 1982, 92 (04): : 1141 - 1149
  • [22] DEVELOPMENT AND EVALUATION OF A QUANTITATIVE LATERAL FLOW IMMUNOASSAY FOR THE DETECTION OF FERRITIN AS POINT-OF-CARE TESTING
    Kimura, Fumiaki
    Miyoshi, Sanami
    Mishima, Yasuo
    Shigeto, Nobuyuki
    Fukuda, Tomoko
    Yamahara, Shigehiro
    Matsumura, Tadashi
    Fujii, Shinji
    Tanimoto, Mitsune
    AMERICAN JOURNAL OF HEMATOLOGY, 2013, 88 (05) : E173 - E173
  • [23] A signal amplifying fluorescent nanoprobe and lateral flow assay for ultrasensitive detection of cardiac biomarker troponin I
    Lou, Doudou
    Fan, Lin
    Ji, Yongxin
    Gu, Ning
    Zhang, Yu
    ANALYTICAL METHODS, 2019, 11 (28) : 3506 - 3513
  • [24] Comparative reactivity and tissue-specificity of cardiac troponin I immunoassay in cardiac and skeletal muscle from different species.
    OBrien, PJ
    Landt, Y
    Ladenson, JH
    CLINICAL CHEMISTRY, 1997, 43 : 397 - 397
  • [25] Development of lateral flow immunoassay system based on superparamagnetic nanobeads as labels for rapid quantitative detection of cardiac troponin I
    Xu, QuanFu
    Xu, Hong
    Gu, Hongchen
    Li, JingBo
    Wang, Yanyan
    Wei, Meng
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (03): : 702 - 707
  • [26] An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers
    Shen, Minjie
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    LAB ON A CHIP, 2020, 20 (15) : 2626 - 2634
  • [27] DETECTION AND MONITORING OF ALCOHOLIC CHRONIC SKELETAL-MUSCLE MYOPATHY BY ASSAYS OF SERUM CARNOSINASE ACTIVITY
    DUANE, P
    SYMES, A
    PETERS, TJ
    QUARTERLY JOURNAL OF MEDICINE, 1986, 61 (235): : 1071 - 1071
  • [28] Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1
    Rong, Zhen
    Wang, Qiong
    Sun, Nanxi
    Jia, Xiaofei
    Wang, Keli
    Xiao, Rui
    Wang, Shengqi
    ANALYTICA CHIMICA ACTA, 2019, 1055 : 140 - 147
  • [29] High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay
    Rodenko, Olga
    Eriksson, Susann
    Tidemand-Lichtenberg, Peter
    Troldborg, Carl Peder
    Fodgaard, Henrik
    van Os, Sylvana
    Pedersen, Christian
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (08): : 3749 - 3762
  • [30] Rapid and Sensitive Detection of Cardiac Troponin I for Point-of-Care Tests Based on Red Fluorescent Microspheres
    Cai, Yanxue
    Kang, Keren
    Li, Qianru
    Wang, Yu
    He, Xiaowei
    MOLECULES, 2018, 23 (05):