共 50 条
The DERIVO 2 Heal Embolization Device in the Treatment of Ruptured and Unruptured Intracranial Aneurysms: a Retrospective Multicenter Study
被引:1
作者:
Schwab, Roland
[1
,2
,12
]
Kabbasch, Christoph
[3
,4
]
Goertz, Lukas
[3
,4
]
Kaschner, Marius
[5
]
Weiss, Daniel
[5
]
Loehr, Christian
[6
]
Wensing, Hauke
[6
]
Bester, Maxim
[7
]
Simgen, Andreas
[8
]
Kemmling, Andre
[9
]
Wendl, Christina
[10
]
Fuchs, Erelle
[1
,2
]
Thormann, Maximilian
[1
,2
]
Behme, Daniel
[1
,2
,12
]
Nordmeyer, Hannes
[11
,13
]
机构:
[1] Otto von Guericke Univ, Univ Clin Neuroradiol, Med Fac, Magdeburg, Germany
[2] Otto von Guericke Univ, Univ Hosp, Magdeburg, Germany
[3] Univ Cologne, Fac Med, Dept Radiol & Neuroradiol, Cologne, Germany
[4] Univ Cologne, Univ Hosp, Cologne, Germany
[5] Univ Dusseldorf, Med Fac, Dept Diagnost & Intervent Radiol, Dusseldorf, Germany
[6] Klinikum Vest, Dept Radiol & Neuroradiol, Recklinghausen, Germany
[7] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Neuroradiol, Hamburg, Germany
[8] Westpfalz Klinikum Kaiserslautern, Dept Neuroradiol, Kaiserslautern, Germany
[9] Univ Marburg, Dept Neuroradiol, Marburg, Germany
[10] Univ Hosp Regensburg, Inst Radiol, Regensburg, Germany
[11] Stadt Klinikum Solingen, Dept Neuroradiol, Solingen, Germany
[12] Otto von Guericke Univ, Res Campus STIMULATE, Magdeburg, Germany
[13] Witten Herdecke Univ, Med Sch, Dept Hlth, Witten, Germany
关键词:
SAH;
hemorrhage;
flow diverter;
endovascular treatment;
cerebral aneurysm;
FLOW-DIVERTOR DEVICES;
RESTENOSIS;
D O I:
10.1007/s00062-024-01446-8
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
BackroundThe use of flow diverting stents in the treatment of intracranial aneurysms is associated with a risk of neurological morbidity due to their thrombogenicity. To reduce this risk different surface modifications have been developed. The Derivo 2 Embolization Device (Acandis, Pforzheim, Germany) has proven to be a safe and effective flow diverter. To overcome the risk of thrombo-embolism, the device was modified by adding an anti-thrombogenic fibrin-heparin coating. We aimed to assess the safety and effectiveness of the Derivo 2 heal Embolization Device. Methods Retrospective multicenter data from nine German neurovascular centers between February 2022 until December 2023 were used. Patients treated with the Derivo 2 heal Embolization Device for unruptured or ruptured intracranial aneurysms were included. Peri- and postprocedural adverse events, clinical outcomes, and angiographic follow-up results were evaluated. Results 84 patients (73.8% female; mean age 58.7 years) with 89 aneurysms (mean size 9.8 mm) were included. 87.6% were located in the anterior circulation. Most of them were sidewall aneurysms (88.8%). 96 flow diverters were used. 99.0% were successfully implanted. An in-stent balloon angioplasty was performed in 6.0% of the cases. An additional coiling was performed in 28.6%. Technical difficulties were present in 12.0% of the cases. Thrombotic events occurred in 4.8% with no neurological sequelae. Mortality and morbidity were 0 and 1.2% respectively. Adequate aneurysm occlusion was achieved in 80.7% with a mean follow-up time of 6.6 months. ConclusionThe Derivo 2 heal Embolization Device showed a satisfying aneurysm occlusion and safety with a low rate of neurological morbidity.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条