Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer

被引:2
|
作者
Shi, Ruyue [1 ,2 ]
Chen, Hailiang [1 ,2 ]
Fan, Xiaoya [3 ]
Liu, Chaoyi [1 ,2 ]
Li, Hongwei [1 ,2 ]
Gao, Zhigang [1 ,2 ]
Zhang, Sa [1 ,2 ]
Gu, Mingqi [1 ,2 ]
Li, Lida [1 ,2 ]
Zheng, Yu [4 ]
Li, Shuguang [1 ,2 ]
机构
[1] Yanshan Univ, Sch Sci, State Key Lab Metastable Mat Sci & Technol, Qinhuangdao 066004, Peoples R China
[2] Yanshan Univ, Key Lab Microstruct Mat Phys Hebei Prov, Qinhuangdao 066004, Peoples R China
[3] Yanshan Univ, Coll Informat Sci & Engn, Qinhuangdao 066004, Hebei, Peoples R China
[4] Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Mach-Zehnder interferometer (MZI); Sagnac interferometer (SI); strain sensor; temperature sensor; vernier effect (VE);
D O I
10.1109/TIM.2024.3427754
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, vernier effect (VE), which is an effective method to enhance the measurement sensitivity of strain and temperature, was experimentally studied through cascading a Mach-Zehnder interferometer (MZI) with a Sagnac interferometer (SI). The MZI consisted of a tapered single-mode fiber (SMF), while the SI was formed using a panda-shaped polarization-maintained fiber (PMF). Free spectral ranges (FSRs) of the two interferometers were slightly different from each other, and as a result, the VE was successfully excited. The experimental results demonstrated that the measurement sensitivity of strain was improved from 26.7 to -110.92 pm/mu epsilon at the temperature of 24 degrees C, while the measurement sensitivity of temperature was improved from -2978 to 7934 pm/degrees C at the strain of 0 epsilon. The sensitivity was amplified about four times. The cross-sensitivity of temperature and strain measurements is 71.53 mu epsilon/degrees C. The proposed sensor exhibits in advantages of simple in construction, high sensitivity, and multiparameter measurements making it a superior contender for strain and temperature monitoring in engineering
引用
收藏
页码:1 / 1
页数:10
相关论文
共 50 条
  • [1] Ultra-sensitive optical fiber ethanol gas sensor based on Vernier effect in cascaded Mach-Zehnder interferometer and Sagnac interferometer
    Gu, Mingqi
    Chen, Hailiang
    Fan, Xiaoya
    Li, Yuxin
    Liu, Chaoyi
    Li, Hongwei
    Shi, Ruyue
    Li, Lida
    Gao, Zhigang
    Zhang, Sa
    Li, Shuguang
    INFRARED PHYSICS & TECHNOLOGY, 2024, 139
  • [2] Paralleled Sagnac interferometer and Mach-Zehnder interferometer for enhanced measurements sensitivity based on Vernier effect
    Shi, Ruyue
    Chen, Hailiang
    Li, Hongwei
    Liu, Chaoyi
    Li, Lida
    Yang, Sigang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (16)
  • [3] Optical fiber temperature sensor with Vernier effect formed by Mach-Zehnder interferometer cascaded Sagnac interferometer based on Hollow-core photonic crystal fiber
    Su, Hang
    Gao, Laixu
    Zhang, Zhaorong
    Kong, Fanxin
    Dong, Zhen
    Zhao, Chunlong
    Xiao, Dehang
    Liu, Chunyu
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2022, 52
  • [4] Highly sensitive temperature and strain sensor based on fiber Sagnac interferometer with Vernier effect
    Zhang, Wujun
    Wu, Xuqiang
    Zuo, Cheng
    Gui, Lei
    Shi, Jinhui
    Zhao, Xiaonan
    Mu, Shengquan
    Liu, Jiaran
    Yu, Benli
    OPTICS COMMUNICATIONS, 2022, 506
  • [5] Cascaded ring resonator and Mach-Zehnder interferometer with a Sagnac loop for Vernier-effect refractive index sensing
    Troia, Benedetto
    De Leonardis, Francesco
    Passaro, Vittorio M. N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 76 - 89
  • [6] Highly Sensitive Temperature Fiber Sensor Based on Mach-Zehnder Interferometer
    Hsu, Jui-Ming
    Chen, Jian-Zhi
    Zheng, Wen-Hao
    FIBER AND INTEGRATED OPTICS, 2016, 35 (5-6) : 230 - 238
  • [7] Optical Waveguide Biosensor Based on Cascaded Mach-Zehnder Interferometer and Ring Resonator with Vernier Effect
    Jiang, Xianxin
    Tang, Longhua
    Song, Jinyan
    Li, Mingyu
    He, Jian-Jun
    FRONTIERS IN BIOLOGICAL DETECTION: FROM NANOSENSORS TO SYSTEMS VII, 2015, 9310
  • [8] Highly sensitive gas pressure sensor based on the enhanced Vernier effect through a cascaded Fabry-Perot and Mach-Zehnder interferometer
    Zhu, Xiping
    Jiang, Chao
    Chen, Hailin
    Wang, Yuan
    Sun, Simei
    Zhang, Han
    Wang, Pei
    Huang, Huiling
    OPTICS EXPRESS, 2022, 30 (19): : 34956 - 34972
  • [9] Sensitivity-Enhanced Temperature Sensor of Cascaded Lyot Filter and Mach-Zehnder Interferometer Based on the Vernier Effect
    Tian, Kaidi
    Wang, Zicheng
    Wang, Guochen
    Wu, Xingliang
    Wang, Yongguang
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23918 - 23928
  • [10] Simulation of a refractive index sensor based on the Vernier effect and a cascaded PANDA and Mach-Zehnder interferometer
    Azizi, Bahram
    Shabankareh, Mohammad Amir Ghasemi
    Farmani, Ali
    JOURNAL OF COMPUTATIONAL ELECTRONICS, 2021, 20 (04) : 1599 - 1610