Simultaneous extraction of polycyclic aromatic hydrocarbons and tetracycline antibiotics from honey samples using dispersive solid phase extraction combined with dispersive liquid-liquid microextraction before their determination with HPLC-DAD

被引:1
作者
Khatami, Arman [1 ]
Moghaddam, Arasb Dabbagh [1 ,2 ]
Talatappeh, Hossein Dini [2 ]
Mohammadimehr, Mojgan [3 ]
机构
[1] Aja Univ Med Sci, Infect Dis Res Ctr, Tehran, Iran
[2] Aja Univ Med Sci, Fac Med, Dept Publ Hlth & Nutr, Tehran, Iran
[3] Aja Univ Med Sci, Fac Paramed, Infect Dis Res Ctr, Dept Lab Sci, Tehran, Iran
关键词
Dispersive solid phase extraction; Magnetic deep eutectic solvent; High-performance liquid chromatography; Polycyclic aromatic hydrocarbons; Honey; HEALTH; RESIDUES; ESTERS; PAHS;
D O I
10.1016/j.jfca.2024.106179
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A dispersive solid-phase extraction method combined with dispersive liquid-liquid microextraction was offered for the extraction of four polycyclic aromatic hydrocarbons (anthracene, fluorene, phenanthrene, and pyrene) and tetracycline antibiotics (tetracycline, oxytetracycline, and chlortetracycline) from honey samples, simultaneously. In this work, cobalt-gallic acid bio-metal organic framework was synthesized and 20 mg of it was added into of 10 mL the diluted honey solution to efficiently adsorb the analytes. After vortexing (3 min) and centrifuging, the sorbent particles were eluted with 0.75 mL acetonitrile under vortexing for 3 min. In the following, this phase was mixed with 55 mu L [Ch: 4-chlorophenol] + [FeCl 4 ] - magnetic deep eutectic solvent and rapidly injected into deionized water. After separating the extractant phase in the presence of an external magnet and diluting it with the mobile phase, it was injected into a high -performance liquid chromatography-diode array detector. Under optimum extraction conditions, extraction recoveries were in the range of 63 -84%. The limits of detection of the opted polycyclic aromatic hydrocarbons and tetracyclines were in the ranges of 0.18 -0.26 and 0.25 -0.29 ng g -1 , respectively. Also, good repeatability (relative standard deviations <= 7.5 and 8.3% for intra - (n=6) and inter -day (n=4) precisions, respectively) was obtained. In summary, the validated method was successfully recommended for the determination of polycyclic aromatic hydrocarbons and tetracyclines in various honey samples and pyrene was found in two samples at 5.5 and 12.9 ng g -1 . The used bio-metal organic framework has sufficient ability in extraction of different classes of compounds (polycyclic aromatic hydrocarbons and antibiotics) from honey. Performing the microextraction step has direct effect in analysis of the analytes in low concentrations and the use of magnetic solvents, eliminate the use of centrifugation in this step.
引用
收藏
页数:7
相关论文
共 33 条
[1]   Metal organic framework/clay composite for micro-dispersive solid-phase extraction of sulfonamides and penicillins in milk, and synthetic urine solution coupling with HPLC/DAD detection [J].
Aldoori, Mahmood Saad ;
Merdivan, Melek ;
Tagac, Aylin Altinisik .
MICROCHEMICAL JOURNAL, 2023, 184
[2]   Synthesis of a zinc-based metal-organic framework with histamine as an organic linker for the dispersive solid-phase extraction of organophosphorus pesticides in water and fruit juice samples [J].
Amiri, Amirhassan ;
Tayebee, Reza ;
Abdar, Abbas ;
Sani, Fatemeh Narenji .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1597 :39-45
[3]   Magnetic deep eutectic solvents in microextraction techniques [J].
Angel Aguirre, Miguel ;
Canals, Antonio .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 146
[4]  
[Anonymous], 2017, Pharma. Innov. J.
[5]   Determination of tetracycline and cefotaxime residues in honey by micro solid phase extraction based on electrospun nanofibers coupled with HPLC [J].
Arabsorkhi, Batoul ;
Sereshti, Hassan .
MICROCHEMICAL JOURNAL, 2018, 140 :241-247
[6]   Antibiotics in food: Legislation and validation of analytical methodologies [J].
Companyo, R. ;
Granados, M. ;
Guiteras, J. ;
Prat, M. D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (04) :877-891
[7]   Extraction techniques with deep eutectic solvents [J].
Cunha, Sara C. ;
Fernandes, Jose O. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 105 :225-239
[8]   Amino group functionalized metal-organic framework as dispersive solid-phase extraction sorbent to determine nitrobenzene compounds in water samples [J].
Dou, Yanan ;
Guo, Lan ;
Li, Guoliang ;
Lv, Xiaoxia ;
Xia, Lian ;
JinmaoYou .
MICROCHEMICAL JOURNAL, 2019, 146 :366-373
[9]   Microextraction methods for the determination of phthalate esters in liquid samples: A review [J].
Farajzadeh, Mir Ali ;
Sorouraddin, Saeed Mohammad ;
Mogaddam, Mohammad Reza Afshar .
JOURNAL OF SEPARATION SCIENCE, 2015, 38 (14) :2470-2487
[10]   Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts. Determination of polybrominated diphenyl ethers by gas chromatography-tandem mass spectrometry [J].
Fontana, Ariel R. ;
Camargo, Alejandra ;
Martinez, Luis D. ;
Altamirano, Jorgelina C. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (18) :2490-2496