Beyond Glucose Monitoring: Multianalyte Sensor Use in Diabetes

被引:0
|
作者
Zhou, Kathy [1 ]
James, Steven [1 ,2 ,3 ,4 ]
Gaca, Michele [1 ,4 ,5 ]
Lecamwasam, Ashani [1 ,5 ]
Dervisevic, Muamer [6 ,7 ]
O'Neal, David [8 ]
Voelcker, Nicolas H. [6 ,7 ,9 ]
Ekinci, Elif I. [1 ,4 ,5 ]
机构
[1] Univ Melbourne, Dept Med, Parkville, Vic, Australia
[2] Univ Sunshine Coast, Sch Hlth, Petrie, Qld, Australia
[3] Western Sydney Univ, Sch Med, Campbelltown, NSW, Australia
[4] Univ Melbourne, Australian Ctr Accelerating Diabet Innovat ACADI, Parkville, Vic, Australia
[5] Austin Hlth, Dept Endocrinol, Heidelberg, Vic, Australia
[6] Monash Univ, Monash Inst Pharmaceut Sci, Drug Delivery Disposit & Dynam, Parkville, Vic, Australia
[7] Melbourne Ctr Nanofabricat, Victorian Node Australian Natl Fabricat Facil, Clayton, Vic 3168, Australia
[8] Univ Melbourne, St Vincents Hosp Melbourne, Dept Med, Fitzroy, Vic, Australia
[9] Monash Univ, Dept Mat Sci & Engn, Clayton, Vic, Australia
关键词
Diabetes mellitus; Continuous glucose monitoring; Continuous ketone monitoring; Multianalyte sensors; Diabetes ketoacidosis; Hyperglycemia; Hypoglycemia; Continuous home monitoring; Self-monitoring of blood glucose;
D O I
10.1089/dia.2024.0250
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The incidence, prevalence, mortality, and health expenditure associated with diabetes continue to grow, despite efforts. The use of multianalyte sensors, which detect glucose as well as key analytes such as ketones, lactate, insulin, uric acid, and electrolytes, may provide additional information to guide earlier identification and management of diabetes and its complications. We undertook a narrative review using a systematic approach in May 2023, with a bridge search undertaken in April 2024. Four biomedical databases were searched: MEDLINE (Ovid), Embase, Emcare, and Cochrane Library. Searches for gray literature were conducted on ClinicalTrials.gov, Google Scholar, and websites of relevant organizations. Included studies incorporated articles on multianalyte sensors in diabetes and single-analyte sensors proposing integration into multianalyte diabetes management, with no limits placed on publication date and study design. Data were screened and extracted using CovidenceTM software. Overall, 11 articles were included, of which 7 involved multianalyte sensors (involving glucose and other analytes) and 4 single-analyte sensors (measuring non-glucose substances for proposed future integration into multianalyte systems). Analytes examined were ketones (n = 3), lactate (n = 4), uric acid (n = 3), insulin (n = 1), and potassium (n = 1). Results demonstrated that in vitro and in vivo measurements of multi- and single-analyte sensors accurately and reliably corresponded with human capillary and serum samples. While the literature on this topic is sparse, our review demonstrated that measurement of glucose and other analytes can be feasibly undertaken using multi- and single-analyte sensors. More studies in humans are needed to establish clinical utility in diabetes self-management and assist with technological improvements.
引用
收藏
页码:885 / 896
页数:12
相关论文
共 50 条
  • [31] Role of continuous glucose monitoring in diabetes management
    Moser, E. G.
    Crew, L. B.
    Garg, S. K.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 73 - 78
  • [32] Optimal Continuous Glucose Monitoring Sensor Calibration for Patients with Type 1 Diabetes
    Zhang, Xiaoran
    Zhang, Wan
    Cao, Yongtong
    Shi, Dawei
    Shi, Ling
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 617 - 622
  • [33] Study of glucose profiles with continuous glucose monitoring in adolescents with poorly controlled type 2 diabetes mellitus
    Lu, Haiyan
    Castells, Salvador
    Hagerty, Dawn
    Quintos, J. B.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2008, 21 (08) : 729 - 736
  • [34] Personal continuous glucose monitoring (CGM) in diabetes management: Review of the literature and implementation for practical use
    Joubert, M.
    Reznik, Y.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 96 (03) : 294 - 305
  • [35] THE USE OF FLASH GLUCOSE MONITORING IN CHILDREN WITH TYPE 1 DIABETES MELLITUS IN REAL CLINICAL PRACTICE
    Laptev, Dmitry N.
    Emelyanov, Andrey O.
    Andrianova, Ekaterina A.
    Zilberman, Lyubov, I
    Eremina, Irina A.
    Svetlova, Galina N.
    Titovich, Elena, V
    Bezlepkina, Olga B.
    Peterkova, Valentina A.
    DIABETES MELLITUS, 2021, 24 (06): : 504 - 510
  • [36] A glucose sensor protein for continuous glucose monitoring
    Veetil, Jithesh V.
    Jin, Sha
    Ye, Kaiming
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) : 1650 - 1655
  • [37] Use of Continuous Glucose Monitoring Systems in Children with Type 1 Diabetes
    Minnock, Pantea P.
    Howe, Carol J.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2011, 23 (02) : 273 - +
  • [38] Continuous Glucose Monitoring Use in Older Adults for Optimal Diabetes Management
    Munshi, Medha N. N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : S56 - S64
  • [39] Transforming diabetes care with continuous glucose monitoring: Rationale for expanded eligibility criteria
    Hirsch, Barbara R.
    JOURNAL OF THE AMERICAN ASSOCIATION OF NURSE PRACTITIONERS, 2024, 36 (07) : 385 - 390
  • [40] Technological advancements in glucose monitoring and artificial pancreas systems for shaping diabetes care
    Ghosh, Neha
    Verma, Saurabh
    CURRENT MEDICAL RESEARCH AND OPINION, 2024, 40 (12) : 2095 - 2107