Non-invasive glucose prediction and classification using NIR technology with machine learning

被引:3
作者
Naresh, M. [1 ]
Nagaraju, V. Siva [2 ]
Kollem, Sreedhar [3 ]
Kumar, Jayendra [1 ]
Peddakrishna, Samineni [1 ]
机构
[1] VIT AP Univ, Sch Elect Engn, Guntur 522241, Andhra Pradesh, India
[2] Inst Aeronaut Engn, Dept ECE, Dundigal, Hyderabad 500043, Telangana, India
[3] SR Univ, Sch Engn, Dept ECE, Warangal 506371, Telangana, India
关键词
Absorbance; Spectroscopy; Glucose; Infrared; Machine learning; Noninvasive; Regression; Classification; Detectors; OPTICAL COHERENCE TOMOGRAPHY; NEAR-INFRARED SPECTROSCOPY; ACCURACY; SENSORS; SYSTEM;
D O I
10.1016/j.heliyon.2024.e28720
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, a dual wavelength short near-infrared system is described for the detection of glucose levels. The system aims to improve the accuracy of blood glucose detection in a cost-effective and non-invasive way. The accuracy of the method is evaluated using real-time samples collected with the reference finger prick glucose device. A feed forward neural network (FFNN) regression method is employed to predict glucose levels based on the input data obtained from NIR technology. The system calculates glucose evaluation metrics and performs Surveillance error grid (SEG) analysis. The coefficient of determination R-2 and mean absolute error are observed 0.99 and 2.49 mg/dl, respectively. Additionally, the system determines the root mean square error (RMSE) as 3.02 mg/dl. It also shows that the mean absolute percentage error (MAPE) is 1.94% and mean squared error (MSE) is 9.16 (mg/dl)(2) for FFNN. The SEG analysis shows that the glucose values measured by the system fall within the clinically acceptable range when compared to the reference method. Finally, the system uses the multi-class classification method of the multilayer perceptron (MLP) and K-nearest neighbors (KNN) classifier to classify glucose levels with an accuracy of 99%.
引用
收藏
页数:22
相关论文
共 66 条
  • [21] Freund Y, 1995, COMPUTATIONAL LEARNI, P23, DOI DOI 10.1007/3-540-59119-2_166
  • [22] Gebhart Suzanne, 2003, Diabetes Technol Ther, V5, P159, DOI 10.1089/152091503321827812
  • [23] The Progress of Glucose MonitoringA Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors
    Gonzales, Wilbert Villena
    Mobashsher, Ahmed Toaha
    Abbosh, Amin
    [J]. SENSORS, 2019, 19 (04)
  • [24] Selection of the most informative near infrared spectroscopy wavebands for continuous glucose monitoring in human serum
    Goodarzi, Mohammad
    Saeys, Wouter
    [J]. TALANTA, 2016, 146 : 155 - 165
  • [25] Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
    Hassan, Mohamed H.
    Vyas, Cian
    Grieve, Bruce
    Bartolo, Paulo
    [J]. SENSORS, 2021, 21 (14)
  • [26] Optical Based Noninvasive Glucose Monitoring Sensor Prototype
    Haxha, Shyqyri
    Jhoja, Jaspreet
    [J]. IEEE PHOTONICS JOURNAL, 2016, 8 (06):
  • [27] Electrochemical glucose sensors and their applications in diabetes management
    Heller, Adam
    Feldman, Ben
    [J]. CHEMICAL REVIEWS, 2008, 108 (07) : 2482 - 2505
  • [28] Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology-A Review
    Hina, Aminah
    Saadeh, Wala
    [J]. SENSORS, 2022, 22 (13)
  • [29] Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications
    Hofmann, Maximilian
    Fischer, Georg
    Weigel, Robert
    Kissinger, Dietmar
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) : 2195 - 2204
  • [30] The hybridization chain reaction in the development of ultrasensitive nucleic acid assays
    Ikbal, Juleiha
    Lim, Geraldine S.
    Gao, Zhiqiang
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 64 : 86 - 99