Mechanical Vertebral Body Augmentation Versus Conventional Balloon Kyphoplasty for Osteoporotic Thoracolumbar Compression Fractures: A Systematic Review and Meta-Analysis of Outcomes

被引:1
|
作者
Macciacchera, Matthew [1 ]
McDonnell, Jake M. [2 ,3 ]
Amir, Aisyah [1 ]
Sowa, Aubrie [2 ,4 ]
Cunniffe, Grainne [2 ]
Darwish, Stacey [2 ]
Murphy, Ciara [3 ,5 ,6 ]
Butler, Joseph S. [2 ,4 ]
机构
[1] Royal Coll Surgeons Ireland, Sch Med, Dublin, Ireland
[2] Mater Misericordiae Univ Hosp, Natl Spinal Injuries Unit, Eccles St, Dublin D07 R2WY, Ireland
[3] Univ Dublin, Trinity Biomed Sci Inst, Trinity Coll Dublin, Trinity Ctr Biomed Engn, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Belfield, Dublin, Ireland
[5] Royal Coll Surgeons Ireland, Dept Anat & Regenerat Med, Dublin, Ireland
[6] Trinity Coll Dublin, Adv Mat & Bioengn Res AMBER Ctr, Dublin, Ireland
关键词
spine surgery; osteoporosis; vertebral body augmentation; comparative; outcomes; SAFETY;
D O I
10.1177/21925682241261988
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design Systematic review and meta-analysis.Objective Surgical management of osteoporotic vertebral compression fractures (OVCFs) has traditionally consisted of vertebroplasty or kyphoplasty procedures. Mechanical percutaneous vertebral body augmentation (MPVA) systems have recently been introduced as alternatives to traditional methods. However, the effectiveness of MPVA systems vs conventional augmentation techniques for OVCFs remains unclear. This serves as the premise for this study.Methods A systematic review and meta-analysis was conducted as per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies of interest included randomized controlled trials (RCTs) which directly compared patient outcomes following kyphoplasty to patients treated with MPVA systems. Clinical and radiological findings were collated and compared for significance between cohorts.Results 6 RCTs were identified with 1024 patients total. The mean age of all patients was 73.5 years. 17% of the cohort were male, 83% were female. 515 patients underwent kyphoplasty and 509 underwent mechanical vertebral body augmentation using MPVA systems. MPVAs showed similar efficacy for restoration of vertebral body height (P = .18), total complications (P = .36), cement extravasation (P = .58) and device-related complications (P = .06). MPVAs also showed reduced rates of all new fractures (16.4% vs 22.2%; P = .17) and adjacent fractures (14.7% vs 18.9%; P = .23), with improved visual analogue scale (VAS) scores at 6-month (P = .13).Conclusion The results of this meta-analysis highlight no significant improvement in clinical or radiological outcomes for MPVA systems when compared to balloon kyphoplasty for vertebral body augmentation. Further research is needed to establish a true benefit over traditional operative methods.
引用
收藏
页码:1356 / 1366
页数:11
相关论文
共 50 条
  • [31] Radiological and Clinical Outcomes of Balloon Kyphoplasty versus Radiofrequency Kyphoplasty in the Treatment of Vertebral Compression Fractures
    Winkelmann, Marcel
    Mavropoulos, Thassia
    Decker, Sebastian
    Omar, Mohamed
    Krettek, Christian
    Mueller, Christian Walter
    ASIAN SPINE JOURNAL, 2018, 12 (05) : 862 - 869
  • [32] Kyphoplasty and vertebroplasty for the management of osteoporotic vertebral compression fractures. A systematic review
    Felder-Puig, R.
    Piso, B.
    Guba, B.
    Gartlehner, G.
    ORTHOPADE, 2009, 38 (07): : 606 - 615
  • [33] Efficacy and safety of balloon kyphoplasty in the treatment of osteoporotic vertebral body compression fractures: Compared with vertebroplasty
    Yi, Won Jae
    Lee, Jung Ho
    Lee, Hyuk Gee
    Ryu, Kee Young
    Kang, Ong Ee
    Kim, Sang Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 42 (02) : 112 - 117
  • [34] Comparative study of balloon kyphoplasty with unilateral versus bilateral approach in osteoporotic vertebral compression fractures
    Chung, Hyung Jin
    Chung, Kook Jin
    Yoon, Hoi Soo
    Kwon, In Hyup
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (06) : 817 - 820
  • [35] Comparative study of balloon kyphoplasty with unilateral versus bilateral approach in osteoporotic vertebral compression fractures
    Hyung Jin Chung
    Kook Jin Chung
    Hoi Soo Yoon
    In Hyup Kwon
    International Orthopaedics, 2008, 32 : 817 - 820
  • [36] Unilateral Versus Bilateral Balloon Kyphoplasty for Multilevel Osteoporotic Vertebral Compression Fractures A Prospective Study
    Chen, Liang
    Yang, Huilin
    Tang, Tiansi
    SPINE, 2011, 36 (07) : 534 - 540
  • [37] Clinical and radiological subsequent fractures after vertebral augmentation for treating osteoporotic vertebral compression fractures: a meta-analysis
    Sun, Hai-Bo
    Jing, Xiao-Shan
    Tang, Hai
    Hai, Yong
    Li, Jin-Jun
    Shan, Jian-Lin
    Wang, De-Cheng
    EUROPEAN SPINE JOURNAL, 2020, 29 (10) : 2576 - 2590
  • [38] Therapeutic Efficacy of Third-Generation Percutaneous Vertebral Augmentation System (PVAS) in Osteoporotic Vertebral Compression Fractures (OVCFs): A Systematic Review and Meta-analysis
    Dong, Chunke
    Zhu, Yuting
    Zhou, Jun
    Dong, Liang
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [39] Effect of vertebral kyphoplasty versus vertebroplasty on pain and indicators of imaging parameters of the injured vertebrae in patients with osteoporotic vertebral compression fractures: a meta-analysis
    You, Zhenjun
    Wu, Keqin
    Jiang, Yi
    Chen, Jing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [40] Balloon kyphoplasty and vertebroplasty for vertebral compression fractures - A comparative systematic review of efficacy and safety
    Taylor, Rod S.
    Taylor, Rebecca J.
    Fritzell, Peter
    SPINE, 2006, 31 (23) : 2747 - 2755