Quantitative Performance Evaluation of Interventions for Pathogens and Chemical Contaminants in Building Water Systems: A Review and Meta-Analysis

被引:3
作者
Quon, Hunter [1 ,2 ]
Alja'fari, Jumana [3 ]
Richard, Rain [4 ]
Kotta, Vishnu [1 ,2 ]
Call, Kathryn [5 ]
Cahill, Molly [1 ,2 ]
Johnson, Elizabeth [6 ]
Brown, James [7 ]
Joshi, Sayalee [7 ]
Boyer, Treavor [2 ]
Voth-Gaeddert, Lee [2 ,8 ]
Hamilton, Kerry A. [1 ,2 ]
机构
[1] Arizona State Univ, Biodesign Inst, Ctr Environm Hlth Engn, Tempe, AZ 85281 USA
[2] Arizona State Univ, Sch Sustainable Engn & Built Environm, Tempe, AZ 85281 USA
[3] NIST, Gaithersburg, MD 20899 USA
[4] Wilson & Co Inc, Phoenix, AZ 85008 USA
[5] Brown & Caldwell, Phoenix, AZ 85004 USA
[6] Carollo Engineers, Phoenix, AZ 85034 USA
[7] Wilson Engineers, Tempe, AZ 85282 USA
[8] Arizona State Univ, Biodesign Inst, Ctr Hlth Microbiomes, Tempe, AZ 85281 USA
来源
ACS ES&T WATER | 2024年 / 4卷 / 09期
基金
美国国家科学基金会;
关键词
COPPER-SILVER IONIZATION; NOSOCOMIAL LEGIONNAIRES-DISEASE; ERADICATING LEGIONELLA-PNEUMOPHILA; DISINFECTION BY-PRODUCTS; DRINKING-WATER; HOT-WATER; OPPORTUNISTIC PATHOGENS; MONOCHLORAMINE TREATMENT; PSEUDOMONAS-AERUGINOSA; BIOFILM FORMATION;
D O I
10.1021/acsestwater.4c00269
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building water systems are associated with variable water age and temperatures, causing water quality concerns. Legionella spp., nontuberculous mycobacteria (NTM), and Pseudomonas spp. are known to inhabit and grow in these systems for which building-level interventions are often required to reduce their concentrations and detections. Other contaminants such as metals and disinfection byproducts (DBPs) are also health concerns. Interventions are typically flushing, temperature manipulation, responsive facility-level interventions (e.g., chemical disinfection and heat shock), or point-of-use devices. A systematic literature review was conducted to summarize interventions targeting pathogen control, and subsequent meta-analysis quantified their respective log reduction values (LRVs). Across the studies (n = 45), Legionella spp. was the primary target (n = 45), and studies varied from laboratory benchtops/pipe racks to hospitals and residential or commercial buildings. Additional measurements and LRVs for heavy metals (e.g., copper, lead, and iron) and DBPs such as trihalomethanes (THMs) were evaluated. The findings pointed to the importance of contextual conditions and incoming water quality in playing a role in both pathogen occurrence and intervention effectiveness. Common interventions such as recommissioning flushing and increased temperature should be further examined for their impacts on pathogens besides Legionella spp. and their contribution to biofilm sloughing and pathogen regrowth. Trade-offs, such as increased metal leaching in parallel with pathogen inactivation, should be examined in context with intervention and building water quality conditions.
引用
收藏
页码:3645 / 3662
页数:18
相关论文
共 154 条
[1]   Longitudinal Evaluation of the Efficacy of Heat Treatment Procedures against Legionella spp. in Hospital Water Systems by Using a Flow Cytometric Assay [J].
Allegra, Severine ;
Grattard, Florence ;
Girardot, Francoise ;
Riffard, Serge ;
Pozzetto, Bruno ;
Berthelot, Philippe .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (04) :1268-1275
[2]  
[Anonymous], 2016, QUANTITATIVE MICROBI
[3]  
[Anonymous], 2016, TECHN LEG CONTR PREM
[4]  
[Anonymous], 2019, MAN LEG WAT SYST
[5]  
[Anonymous], 2004, Guidelines for Drinking Water Quality, V1
[6]  
[Anonymous], 2012, 2012 GUID WAT REUS
[7]  
[Anonymous], 2019, LEG DIS SURV SUMM RE
[8]  
[Anonymous], 1999, Legionella Human Health Criteria Document
[9]  
[Anonymous], 2006, DRINK WAT DISTR SYST
[10]  
[Anonymous], 2011, WATER SAFETY INBUILD