Autofluorescence lifetime flow cytometry with time-correlated single photon counting

被引:3
作者
Samimi, Kayvan [1 ]
Pasachhe, Ojaswi [1 ]
Guzman, Emmanuel Contreras [1 ]
Riendeau, Jeremiah [1 ]
Gillette, Amani A. [1 ]
Pham, Dan L. [2 ]
Wiech, Kasia J. [2 ]
Moore, Darcie L. [3 ]
Skala, Melissa C. [1 ,2 ]
机构
[1] Morgridge Inst Res, Madison, WI 53715 USA
[2] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[3] Univ Wisconsin, Dept Neurosci, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
flow cytometry; fluorescence lifetime; label-free sensing; metabolism; NAD(P)H; single-cell analysis; time tagger; FLUORESCENCE-LIFETIME; MICROSCOPY; NADH; QUIESCENCE; NAD(P)H; CELLS;
D O I
10.1002/cyto.a.24883
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Autofluorescence lifetime imaging microscopy (FLIM) is sensitive to metabolic changes in single cells based on changes in the protein-binding activities of the metabolic co-enzymes NAD(P)H. However, FLIM typically relies on time-correlated single-photon counting (TCSPC) detection electronics on laser-scanning microscopes, which are expensive, low-throughput, and require substantial post-processing time for cell segmentation and analysis. Here, we present a fluorescence lifetime-sensitive flow cytometer that offers the same TCSPC temporal resolution in a flow geometry, with low-cost single-photon excitation sources, a throughput of tens of cells per second, and real-time single-cell analysis. The system uses a 375 nm picosecond-pulsed diode laser operating at 50 MHz, alkali photomultiplier tubes, an FPGA-based time tagger, and can provide real-time phasor-based classification (i.e., gating) of flowing cells. A CMOS camera produces simultaneous brightfield images using far-red illumination. A second PMT provides two-color analysis. Cells are injected into the microfluidic channel using a syringe pump at 2-5 mm/s with nearly 5 ms integration time per cell, resulting in a light dose of 2.65 J/cm2 that is well below damage thresholds (25 J/cm2 at 375 nm). Our results show that cells remain viable after measurement, and the system is sensitive to autofluorescence lifetime changes in Jurkat T cells with metabolic perturbation (sodium cyanide), quiescent versus activated (CD3/CD28/CD2) primary human T cells, and quiescent versus activated primary adult mouse neural stem cells, consistent with prior studies using multiphoton FLIM. This TCSPC-based autofluorescence lifetime flow cytometer provides a valuable label-free method for real-time analysis of single-cell function and metabolism with higher throughput than laser-scanning microscopy systems.
引用
收藏
页码:607 / 620
页数:14
相关论文
共 50 条
[41]   Accurate single-pair Forster resonant energy transfer through combination of pulsed interleaved excitation, time correlated single-photon counting, and fluorescence correlation spectroscopy [J].
Rüttinger, S ;
Macdonald, R ;
Krämer, B ;
Koberling, F ;
Roos, M ;
Hildt, E .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
[42]   Single-Photon, Time-Gated, Phasor-Based Fluorescence Lifetime Imaging through Highly Scattering Medium [J].
Ankri, Rinat ;
Basu, Arkaprabha ;
Ulku, Arin Can ;
Bruschini, Claudio ;
Charbon, Edoardo ;
Weiss, Shimon ;
Michalet, Xavier .
ACS PHOTONICS, 2020, 7 (01) :68-79
[43]   Comparison of Volumetric and Bead-Based Counting of CD34 Cells by Single-Platform Flow Cytometry [J].
Saraiva, Luisa ;
Wang, Lili ;
Kammel, Martin ;
Kummrow, Andreas ;
Atkinson, Eleanor ;
Lee, Ji Youn ;
Yalcinkaya, Burhanettin ;
Akgoez, Muslum ;
Hoeckner, Jana ;
Ruf, Andreas ;
Engel, Andrea ;
Zhang, Yu-Zhong ;
O'Shea, Orla ;
Sassi, Maria Paola ;
Divieto, Carla ;
Lekishvili, Tamara ;
Campbell, Jonathan ;
Liu, Yingying ;
Wang, Jing ;
Stebbings, Richard ;
Gaigalas, Adolfas K. ;
Rigsby, Peter ;
Neukammer, Joerg ;
Vessillier, Sandrine .
CYTOMETRY PART B-CLINICAL CYTOMETRY, 2019, 96 (06) :508-513
[44]   FoCuS-point: software for STED fluorescence correlation and time-gated single photon counting [J].
Waithe, Dominic ;
Clausen, Mathias P. ;
Sezgin, Erdinc ;
Eggeling, Christian .
BIOINFORMATICS, 2016, 32 (06) :958-960
[45]   UV LED excited time-gated luminescence flow cytometry: Evaluation for rare-event particle counting [J].
Jin, Dayong ;
Ferrari, Belinda ;
Leif, Robert ;
Yang, Sean ;
Vallarino, Lidia M. ;
WilliamS, John ;
Piper, James .
IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VI, 2008, 6859
[46]   NAD(P)H autofluorescence lifetime imaging enables single cell analyses of cellular metabolism of osteoblasts in vitro and in vivo via two-photon microscopy [J].
Schilling, Kevin ;
Brown, Edward ;
Zhang, Xinping .
BONE, 2022, 154
[47]   Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry [J].
Koyalta, Donato ;
Jenabian, Mohammad-Ali ;
Djouater, Barou ;
Djemadji-Oudjeil, Noel ;
Mbopi-Keou, Francois-Xavier ;
Ndjoyi-Mbiguino, Angelique ;
Belec, Laurent .
BMC HEALTH SERVICES RESEARCH, 2013, 13
[48]   Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry [J].
Donato Koyalta ;
Mohammad-Ali Jenabian ;
Barou Djouater ;
Noël Djemadji-Oudjeil ;
Francois-Xavier Mbopi-Keou ;
Angélique Ndjoyi-Mbiguino ;
Laurent Bélec .
BMC Health Services Research, 13
[49]   Comparison of GP IIB/IIIA Inhibitors and Their Activity as Measured by Aggregometry, Flow Cytometry, Single Platelet Counting, and the Rapid Platelet Function Analyzer [J].
Axel C. Matzdorff ;
Gitta Kühnel ;
Bettina Kemkes-Matthes ;
Reinhard Voss .
Journal of Thrombosis and Thrombolysis, 2001, 12 :129-139
[50]   Comparison of GP IIB/IIIA inhibitors and their activity as measured by aggregometry, flow cytometry, single platelet counting, and the rapid platelet function analyzer [J].
Matzdorff, AC ;
Kühnel, G ;
Kemkes-Matthes, B ;
Voss, R .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2001, 12 (02) :129-139