The Efficiency of an Advanced Hybrid Closed Insulin Pump in Patients with Type 1 Diabetes for Improved Blood Glucose Control

被引:0
作者
Owaydah, Amal [1 ,2 ]
Abouglila, Kamal [1 ]
Liloglou, Triantafillos
机构
[1] Univ Hosp North Durham, Dept Endocrine, 9 Taylor Court, Durham DH1 1EL, England
[2] Edge Hill Univ, Fac Hlth Social Care & Med, Ormskirk, England
关键词
type; 1; diabetes; insulin pump; artificial pancreas; closed loop; QUALITY-OF-LIFE;
D O I
10.1055/s-0044-1787111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Diabetes technology, especially advanced hybrid closed-loop (AHCL) systems, is rapidly advancing, offering improved glycemic control, reduced hypoglycemia, and reduced treatment burden for patients with type 1 diabetes (T1D). This study aimed to evaluate the clinical efficiency of an AHCL system-the Medtronic MiniMed 780G insulin pump combined with continuous glucose monitoring-among individuals with T1D in real-world clinical settings. Methods In an observational retrospective study, we identified a cohort of 41 patients (mean age, 47.1 +/- 13.7 years; T1D duration, 23.6 +/- 13 years; 73.2% female) previously using an insulin pump or those on multiple daily insulin injections, currently using the AHCL system for at least 6 months. Primary outcomes were the changes of the following parameters, before AHCL initiation and at 6 months after treatment; (1) time in range (TIR): time with glucose levels in the range of 70 to 180 mg/dL, (2) time below range (TBR): time with glucose levels below 70 mg/dL, and (3) time above range (TAR): time with glucose levels above 180 mg/dL. Results Data analysis from 41 patients showed a significant 16.5% +/- 13.8% increase in TIR (from 56.6 +/- 17.9 to 73.1 +/- 10.6%, p < 0.001). Both TBR and TAR decreased by 2.9 +/- 4.8% (p = 0.004) and 13.6 +/- 16.4% (p < 0.001), respectively. Mean glucose concentration, coefficient of variation, and glucose management indicator significantly improved. Conclusion The AHCL system effectively improved glucose control regarding TIR, TBR, and TAR. Enhanced glycemic control metrics highlight the potential for wider adoption of AHCL technology.
引用
收藏
页码:96 / 99
页数:4
相关论文
共 15 条
[1]   INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM [J].
Aleppo, Grazia ;
Webb, Kimberly M. .
ENDOCRINE PRACTICE, 2018, 24 (07) :684-692
[2]  
[Anonymous], ARTIFICIAL PANCREAS
[3]  
[Anonymous], Care processes and treatment targets, overview Internet
[4]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[5]   Hybrid closed-loop glucose control compared with sensor augmented pump therapy in older adults with type 1 diabetes: an open-label multicentre, multinational, randomised, crossover study [J].
Boughton, Charlotte K. ;
Hartnell, Sara ;
Thabit, Hood ;
Mubita, Womba M. ;
Draxlbauer, Katharine ;
Poettler, Tina ;
Wilinska, Malgorzata E. ;
Hood, Korey K. ;
Mader, Julia K. ;
Narendran, Parth ;
Leelarathna, Lalantha ;
Evans, Mark L. ;
Hovorka, Roman .
LANCET HEALTHY LONGEVITY, 2022, 3 (03) :E135-E142
[6]   Effect of Continuous Glucose Monitoring on Glycemic Control, Acute Admissions, and Quality of Life: A Real-World Study [J].
Charleer, Sara ;
Mathieu, Chantal ;
Nobels, Frank ;
De Block, Christophe ;
Radermecker, Regis P. ;
Hermans, Michel P. ;
Taes, Youri ;
Vercammen, Chris ;
T'Sjoen, Guy ;
Crenier, Laurent ;
Fieuws, Steffen ;
Keymeulen, Bart ;
Gillard, Pieter .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2018, 103 (03) :1224-1232
[7]   Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users [J].
Da Silva, Julien ;
Lepore, Giuseppe ;
Battelino, Tadej ;
Arrieta, Arcelia ;
Castaneda, Javier ;
Grossman, Benyamin ;
Shin, John ;
Cohen, Ohad .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (02) :113-119
[8]   UK's Association of British Clinical Diabetologist's Diabetes Technology Network (ABCD-DTN): Best practice guide for hybrid closed-loop therapy [J].
Griffin, Tomas P. ;
Gallen, Geraldine ;
Hartnell, Sara ;
Crabtree, Thomas ;
Holloway, Melissa ;
Gibb, Fraser W. W. ;
Lumb, Alistair ;
Wilmot, Emma G. G. ;
Choudhary, Pratik ;
Hussain, Sufyan .
DIABETIC MEDICINE, 2023, 40 (07)
[9]   Real-world evidence on clinical outcomes of people with type 1 diabetes using open-source and commercial automated insulin dosing systems: A systematic review [J].
Knoll, Christine ;
Peacock, Sofia ;
Waldchen, Mandy ;
Cooper, Drew ;
Aulakh, Simran Kaur ;
Raile, Klemens ;
Hussain, Sufyan ;
Braune, Katarina .
DIABETIC MEDICINE, 2022, 39 (05)
[10]  
Kumareswaran Kavita, 2011, J Diabetes Sci Technol, V5, P1352