Comparative Evaluation of Er: YAG Laser, Diode Laser, and Novamin Technology for Dentinal Tubule Occlusion: An In-Vitro Scanning Electron Microscope (SEM) and Energy Dispersive X-Ray Analysis (EDX) Study

被引:3
作者
Srivastava, Vivek [1 ]
Haldar, Shreya [1 ]
Srivastava, Vipul [2 ]
Meenawat, Ajita [1 ]
Khan, Yasir Shahab [1 ]
Huidrom, Elizabeth [1 ]
机构
[1] Sardar Patel Post Grad Inst Dent & Med Sci, Dept Periodontol, Lucknow, India
[2] 32 Pearls Dent Clin, Dept Conservat Dent & Endodont, Lucknow, India
关键词
energy dispersive x-ray analysis; scanning electron microscope; lasers; dentinal tubule occlusion; dentinal hypersensitivity; SODIUM-FLUORIDE GEL; ERYAG LASER; HYPERSENSITIVITY; PAIN;
D O I
10.7759/cureus.58806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dentinal hypersensitivity is a brief and painful oral condition that is characterized by an abrupt shooting sensation. Stimulation occurs when hot, cold, sweet, or sour food comes into contact with exposed dentinal tubules. The present study used a scanning electron microscope (SEM) and energy dispersive X-ray analysis (EDX) to investigate the efficacy of Er: YAG, 810 nm diode LASER, and NovaMin Technology in obstructing dentinal tubules. Material and methods: We extracted the outer layers of 30 human teeth to expose the tubules and then treated the surfaces with 17% ethylenediaminetetraacetic acid (EDTA) to create an etched effect. Three cohorts were created from the portions. Group A was subjected to the application of Erbium:YttriumAluminum-Garnet (Er: YAG) laser with a power output of 2W in the non -contact mode for 1 minute. Group B was subjected to the application of an 810nm diode laser with a power output of 1W in continuous mode for 30 seconds. Group C was subjected to the application of NovaMin paste, which contains a 927 ppm fluoride content. Following the therapy, occluded dentinal tubules were analyzed using scanning electron microscopy (SEM) and energy -dispersive X-ray spectroscopy (EDX) for both quantitative and qualitative examination. The data analysis was conducted using a one-way analysis of variance (ANOVA) and Tukey's test, with a significance threshold of 0.05. Results: The average percentages of complete blockage of dentinal tubules in Groups A, B, and C were evaluated using the number of entirely unobstructed dentinal tubules at magnifications of 2000X (F = 3.05, p = 0.064), 5000X (F = 5.33, p = 0.011), and 10000X (F = 8.63, p = 0.001). The count of partially open dentinal tubules seen at magnifications of 2000X, 5000X, and 10000X was F = 10.15 (P < 0.001), F = 5.97 (p = 0.007), and F = 2.12 (p = 0.140) accordingly. Conclusion: NovaMin technology has demonstrated more effectiveness in blocking dentinal tubules compared to 810nm diodes and Er: YAG lasers.
引用
收藏
页数:9
相关论文
共 34 条
[1]  
Aldelaimi AA, 2021, J RES MED DENT SCI, V9, P66
[2]   Clinical Application of Diode Laser (980 nm) in Maxillofacial Surgical Procedures [J].
Aldelaimi, Tahrir N. ;
Khalil, Afrah A. .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) :1220-1223
[3]  
Asnaashari M, 2013, J LASERS MED SCI, V4, P1
[4]  
Bari LWM, 2019, Acta Scientific Dental Sciences, V3, P57
[5]   A comparative evaluation of CO2 and erbium-doped yttrium aluminium garnet laser therapy in the management of dentin hypersensitivity and assessment of mineral content [J].
Belal, Mahmoud Helmy ;
Yassin, Abdulaziz .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (05) :227-234
[6]   Laser-assisted treatment of dentinal hypersensitivity: a literature review [J].
Biagi, Roberto ;
Cossellu, Gianguido ;
Sarcina, Michele ;
Pizzamiglio, Ilaria Tina ;
Farronato, Giampietro .
ANNALI DI STOMATOLOGIA, 2015, 6 (3-4) :75-80
[7]  
Bm Shivaprasad, 2014, J Clin Diagn Res, V8, pZC05, DOI 10.7860/JCDR/2014/8824.4947
[8]  
Brannstrom M, 1963, sensory mechanisms in dentine. Oxford Reference, V1, P88
[9]  
Bretz Walter A, 2002, J Evid Based Dent Pract, V2, P267
[10]  
Burwell Anora, 2010, J Clin Dent, V21, P66