Impact of Microbubble Degradation and Flow Velocity on Subharmonic-aided Pressure Estimation (SHAPE): An Experimental Investigation

被引:2
作者
Zhang, Li [1 ]
Dong, Yi-fan [1 ]
Chen, Yao [2 ]
Li, Xiao-gang [3 ]
Wang, Ya-hong [1 ]
Wang, Ying [1 ]
Ge, Zhi-tong [1 ]
Wang, Xin [1 ]
Cai, Sheng [4 ]
Yang, Xiao [1 ]
Zhu, Qing-li [1 ]
Li, Jian-chu [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China
[2] GE Healthcare Med Syst China, Dept Ultrasound, Shanghai, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Biobank Facil,Natl Infrastruct Translat Med, Beijing, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Hlth Med, Beijing, Peoples R China
关键词
Ultrasound; Microbubbles; Subharmonic imaging; Intravascular pressure measurement; Subharmonic-aided Pressure Estimation; PORTAL-HYPERTENSION; BLOOD-PRESSURE; IN-VITRO; SIGNALS; PARAMETERS; DEPENDENCE; EMISSIONS;
D O I
10.1016/j.ultrasmedbio.2024.03.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: This study aimed to investigate the impact of microbubble degradation and flow velocity on Sub-Harmonic Aided Pressure Estimation (SHAPE), and to explore the correlation between subharmonic amplitude and pressure as a single factor. Methods: We develop an open-loop vascular phantom platform system and utilize a commercial ultrasound machine and microbubbles for subharmonic imaging. Subharmonic amplitude was measured continuously at constant pressure and flow velocity to assess the impact of microbubble degradation. Flow velocity was varied within a range of 4-14 cm/s at constant pressure to investigate its relationship to subharmonic amplitude. Furthermore, pressure was varied within a range of 10-110 mm Hg at constant flow velocity to assess its isolated effect on subharmonic amplitude. Results: Under constant pressure and flow velocity, subharmonic amplitude exhibited a continuous decrease at an average rate of 0.221 dB/min, signifying ongoing microbubble degradation during the experimental procedures. Subharmonic amplitude demonstrated a positive correlation with flow velocity, with a variation ratio of 0.423 dB/(cm/s). Under controlled conditions of microbubble degradation and flow velocity, a strong negative linear correlation was observed between pressure and subharmonic amplitude across different Mechanical Index (MI) settings (all R-2 > 0.90). The sensitivity of SHAPE was determined to be 0.025 dB/mmHg at an MI of 0.04. Conclusion: The assessment of SHAPE sensitivity is affected by microbubble degradation and flow velocity. Excluding the aforementioned influencing factors, a strong linear negative correlation between pressure and subharmonic amplitude was still evident, albeit with a sensitivity coefficient lower than previously reported values.
引用
收藏
页码:1020 / 1027
页数:8
相关论文
共 42 条
  • [11] Chronic Liver Disease: Noninvasive Subharmonic Aided Pressure Estimation of Hepatic Venous Pressure Gradient
    Eisenbrey, John R.
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Merton, Daniel A.
    Miller, Cynthia
    Gonzalez, Jose M.
    Machado, Priscilla
    Park, Suhyun
    Dianis, Scott
    Chalek, Carl L.
    Kim, Christopher E.
    Baliff, Jeffrey P.
    Thomenius, Kai E.
    Brown, Daniel B.
    Navarro, Victor
    Forsberg, Flemming
    [J]. RADIOLOGY, 2013, 268 (02) : 581 - 588
  • [12] Noninvasive Evaluation of Cardiac Chamber Pressures Using Subharmonic-Aided Pressure Estimation With Definity Microbubbles
    Esposito, Cara
    Machado, Priscilla
    McDonald, Maureen E.
    Savage, Michael P.
    Fischman, David
    Mehrotra, Praveen
    Cohen, Ira S.
    Ruggiero, Nicholas, II
    Walinsky, Paul
    Vishnevsky, Alec
    Dickie, Kristopher
    Davis, Marguerite
    Forsberg, Flemming
    Dave, Jaydev K.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2023, 16 (02) : 224 - 235
  • [13] Developing an Interface and Investigating Optimal Parameters for Real-Time Intracardiac Subharmonic-Aided Pressure Estimation
    Esposito, Cara
    Dickie, Kris
    Forsberg, Flemming
    Dave, Jaydev K.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 579 - 585
  • [14] In vivo pressure estimation using subharmonic contrast microbubble signals: Proof of concept
    Forsberg, F
    Liu, JB
    Shi, WT
    Furuse, J
    Shimizu, M
    Goldberg, BB
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (04) : 581 - 583
  • [15] Subharmonic imaging of contrast agents
    Forsberg, F
    Shi, WT
    Goldberg, BB
    [J]. ULTRASONICS, 2000, 38 (1-8) : 93 - 98
  • [16] Contrast-Enhanced Subharmonic Aided Pressure Estimation (SHAPE) using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
    Forsberg, Flemming
    Gupta, Ipshita
    Machado, Priscilla
    Shaw, Colette M.
    Fenkel, Jonathan M.
    Wallace, Kirk
    Eisenbrey, John R.
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (166): : 1 - 12
  • [17] Subharmonic Scattering of Phospholipid-Shell Microbubbles at Low Acoustic Pressure Amplitudes
    Frinking, Peter J. A.
    Gaud, Emmanuel
    Brochot, Jean
    Arditi, Marcel
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (08) : 1762 - 1771
  • [18] Diagnosing Portal Hypertension with Noninvasive Subharmonic Pressure Estimates from a US Contrast Agent
    Gupta, Ipshita
    Eisenbrey, John R.
    Machado, Priscilla
    Stanczak, Maria
    Wessner, Corinne E.
    Shaw, Colette M.
    Gummadi, Sriharsha
    Fenkel, Jonathan M.
    Tan, Alison
    Miller, Cynthia
    Parent, Julia
    Schultz, Susan
    Soulen, Michael C.
    Sehgal, Chandra M.
    Wallace, Kirk
    Forsberg, Flemming
    [J]. RADIOLOGY, 2021, 298 (01) : 104 - 111
  • [19] On Factors Affecting Subharmonic-aided Pressure Estimation (SHAPE)
    Gupta, Ipshita
    Eisenbrey, John R.
    Machado, Priscilla
    Stanczak, Maria
    Wallace, Kirk
    Forsberg, Flemming
    [J]. ULTRASONIC IMAGING, 2019, 41 (01) : 35 - 48
  • [20] Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo
    Gupta, Ipshita
    Eisenbrey, John
    Stanczak, Maria
    Sridharan, Anush
    Dave, Jaydev K.
    Liu, Ji-Bin
    Hazard, Christopher
    Wang, Xinghua
    Wang, Ping
    Li, Huiwen
    Wallace, Kirk
    Forsberg, Flemming
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (01) : 3 - 11