Impact of Microbubble Degradation and Flow Velocity on Subharmonic-aided Pressure Estimation (SHAPE): An Experimental Investigation

被引:2
作者
Zhang, Li [1 ]
Dong, Yi-fan [1 ]
Chen, Yao [2 ]
Li, Xiao-gang [3 ]
Wang, Ya-hong [1 ]
Wang, Ying [1 ]
Ge, Zhi-tong [1 ]
Wang, Xin [1 ]
Cai, Sheng [4 ]
Yang, Xiao [1 ]
Zhu, Qing-li [1 ]
Li, Jian-chu [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China
[2] GE Healthcare Med Syst China, Dept Ultrasound, Shanghai, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Biobank Facil,Natl Infrastruct Translat Med, Beijing, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Hlth Med, Beijing, Peoples R China
关键词
Ultrasound; Microbubbles; Subharmonic imaging; Intravascular pressure measurement; Subharmonic-aided Pressure Estimation; PORTAL-HYPERTENSION; BLOOD-PRESSURE; IN-VITRO; SIGNALS; PARAMETERS; DEPENDENCE; EMISSIONS;
D O I
10.1016/j.ultrasmedbio.2024.03.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: This study aimed to investigate the impact of microbubble degradation and flow velocity on Sub-Harmonic Aided Pressure Estimation (SHAPE), and to explore the correlation between subharmonic amplitude and pressure as a single factor. Methods: We develop an open-loop vascular phantom platform system and utilize a commercial ultrasound machine and microbubbles for subharmonic imaging. Subharmonic amplitude was measured continuously at constant pressure and flow velocity to assess the impact of microbubble degradation. Flow velocity was varied within a range of 4-14 cm/s at constant pressure to investigate its relationship to subharmonic amplitude. Furthermore, pressure was varied within a range of 10-110 mm Hg at constant flow velocity to assess its isolated effect on subharmonic amplitude. Results: Under constant pressure and flow velocity, subharmonic amplitude exhibited a continuous decrease at an average rate of 0.221 dB/min, signifying ongoing microbubble degradation during the experimental procedures. Subharmonic amplitude demonstrated a positive correlation with flow velocity, with a variation ratio of 0.423 dB/(cm/s). Under controlled conditions of microbubble degradation and flow velocity, a strong negative linear correlation was observed between pressure and subharmonic amplitude across different Mechanical Index (MI) settings (all R-2 > 0.90). The sensitivity of SHAPE was determined to be 0.025 dB/mmHg at an MI of 0.04. Conclusion: The assessment of SHAPE sensitivity is affected by microbubble degradation and flow velocity. Excluding the aforementioned influencing factors, a strong linear negative correlation between pressure and subharmonic amplitude was still evident, albeit with a sensitivity coefficient lower than previously reported values.
引用
收藏
页码:1020 / 1027
页数:8
相关论文
共 42 条
  • [1] Ambient Pressure Sensitivity of the Subharmonic Response of Coated Microbubbles: Effects of Acoustic Excitation Parameters
    Azami, Roozbeh H.
    Forsberg, Flemming
    Eisenbrey, John R.
    Sarkar, Kausik
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (07) : 1550 - 1560
  • [2] Arterial stiffness indices in healthy volunteers using non-invasive digital photoplethysmography
    Brillante, Divina G.
    O'Sullivan, Anthony J.
    Howes, Laurence G.
    [J]. BLOOD PRESSURE, 2008, 17 (02) : 116 - 123
  • [3] Nondestructive subharmonic imaging
    Chomas, J
    Dayton, P
    May, D
    Ferrara, K
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) : 883 - 892
  • [4] On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation
    Dave, J. K.
    Halldorsdottir, V. G.
    Eisenbrey, J. R.
    Merton, D. A.
    Liu, J. B.
    Machado, P.
    Zhao, H.
    Park, S.
    Dianis, S.
    Chalek, C. L.
    Thomenius, K. E.
    Brown, D. B.
    Forsberg, F.
    [J]. ULTRASONICS, 2013, 53 (04) : 880 - 888
  • [5] NON-INVASIVE INTRA-CARDIAC PRESSURE MEASUREMENTS USING SUBHARMONIC-AIDED PRESSURE ESTIMATION: PROOF OF CONCEPT IN HUMANS
    Dave, Jaydev K.
    Kulkarni, Sushmita V.
    Pangaonkar, Purva P.
    Stanczak, Maria
    McDonald, Maureen E.
    Cohen, Ira S.
    Mehrotra, Praveen
    Savage, Michael P.
    Walinsky, Paul
    Ruggiero, Nicholas J., II
    Fischman, David L.
    Ogilby, David
    VanWhy, Carolyn
    Lombardii, Matthew
    Forsberg, Flemming
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (11) : 2718 - 2724
  • [6] INVESTIGATING THE EFFICACY OF SUBHARMONIC AIDED PRESSURE ESTIMATION FOR PORTAL VEIN PRESSURES AND PORTAL HYPERTENSION MONITORING
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Merton, Daniel A.
    Liu, Ji-Bin
    Zhou, Jian-Hua
    Wang, Hsin-Kai
    Park, Suhyun
    Dianis, Scott
    Chalek, Carl L.
    Lin, Feng
    Thomenius, Kai E.
    Brown, Daniel B.
    Forsberg, Flemming
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (10) : 1784 - 1798
  • [7] Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Raichlen, Joel S.
    Liu, Ji-Bin
    McDonald, Maureen E.
    Dickie, Kris
    Wang, Shumin
    Leung, Corina
    Forsberg, Flemming
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 303 (01): : H126 - H132
  • [8] Noninvasive LV Pressure Estimation Using Subharmonic Emissions From Microbubbles
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Raichlen, Joel S.
    Liu, Ji-Bin
    McDonald, Maureen E.
    Dickie, Kris
    Wang, Shumin
    Leung, Corina
    Forsberg, Flemming
    [J]. JACC-CARDIOVASCULAR IMAGING, 2012, 5 (01) : 87 - 92
  • [9] Noninvasive Estimation of Dynamic Pressures In Vitro and In Vivo Using the Subharmonic Response From Microbubbles
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Liu, Ji-Bin
    McDonald, Maureen E.
    Dickie, Kris
    Leung, Corina
    Forsberg, Flemming
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (10) : 2056 - 2066
  • [10] Diagnostic accuracy of contrast-enhanced ultrasound for detecting clinically significant portal hypertension and severe portal hypertension in chronic liver disease: a meta-analysis
    Duan, Yayang
    Dong, Bingtian
    Li, Siyao
    Zhang, Chaoxue
    [J]. EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2023, 17 (05) : 489 - 497