Indoor particulate matter exposure and correlation of PM2.5 with lung efficacy and SpO2 level of Dhaka City Dwellers

被引:1
作者
Nahian, Samiha [1 ]
Roy, Shatabdi [1 ]
Choudhury, Tasrina Rabia [2 ]
Begum, Bilkis Ara [2 ]
Salam, Abdus [1 ]
机构
[1] Univ Dhaka, Fac Sci, Dept Chem, Dhaka 1000, Bangladesh
[2] Atom Energy Ctr, Chem Div, Dhaka 1000, Bangladesh
关键词
Indoor particulate matter; Infiltration; Haze; Lung efficacy; SpO(2); AIR-POLLUTION; HEALTH-RISK; SEVERE HAZE; FINE PM; PARTICLES; IMPACTS; POLLUTANTS; COMPONENTS; EMISSIONS; TRANSPORT;
D O I
10.1007/s11869-024-01586-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated indoor exposure of particulate matter (PM) at six residential homes in Dhaka, Bangladesh, to assess the degradation of indoor air quality (IAQ) by PM1.0, PM2.5 and PM10, as well as correlate indoor PM2.5 with occupants' lung efficacy and blood oxygen saturation (SpO(2)). Concentrations of indoor and outdoor PM were monitored individually at day and night using IGERESS Air Quality Monitoring Detector. Mean concentration of indoor PM1.0, PM2.5 and PM10 were 91.7 +/- 47.2, 121 +/- 62.4, and 140 +/- 72.0 mu gm(- 3), respectively. Indoor PM of all size ranges at night were found to be 1.69 times higher than their corresponding daytime concentration. Mean I/O ratio (I/O-day= 0.95 and I/O-night= 0.93) and strong positive correlation (R-day(2)= 0.90 and R-night(2) = 0.80) between indoor and outdoor PM confirmed infiltration of polluted outdoor air inside the households. Indoor sources had 11% and 14% contribution to indoor PM during day and night, respectively. For Cantonment site, PM measurement was conducted during haze and non- haze weather. Haze- time PM concentration was 1.55 to 1.86 times greater than the non- haze period, which indicated that despite the same indoor environment, infiltrated outdoor PM during haze deteriorated IAQ. The average peak flow rate and SpO(2) of 30 inhabitants in six sampling households were 353 L min(- 1) and 98.7%, respectively. Peak flow rate showed strong, negative correlation (R-2 = 0.82) with indoor PM2.5 concentration, which implied that inhalation of excess PM2.5 was probably responsible for the reduced lung function of the residents. However, no association could be established between SpO(2) and indoor PM2.5 concentration. These outcomes indicated severely compromised IAQ in urban Dhaka households, so necessary measures are required to reduce the extent of indoor air pollution.
引用
收藏
页码:2515 / 2528
页数:14
相关论文
共 50 条
  • [21] The association between airborne particulate matter (PM2.5) exposure level and primary open-angle glaucoma
    Ma, Yi
    Shao, Mingxi
    Li, Shengjie
    Lei, Yuan
    Cao, Wenjun
    Sun, Xinghuai
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2024, 283
  • [22] Occupational Exposure to Fine Particulate Matter (PM4 and PM2.5) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
    Shezi, Busisiwe
    Mathee, Angela
    Cele, Nokulunga
    Ndabandaba, Sipho
    Street, Renee A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 13
  • [23] Black Carbon and Particulate Matter (PM2.5) Concentrations in New York City's Subway Stations
    Vilcassim, M. J. Ruzmyn
    Thurston, George D.
    Peltier, Richard E.
    Gordon, Terry
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (24) : 14738 - 14745
  • [24] Emission Source Areas of Fine Particulate Matter (PM2.5) in Ho Chi Minh City, Vietnam
    Nguyen, Tuyet Nam Thi
    Du, Nguyen Xuan
    Hoa, Nguyen Thi
    ATMOSPHERE, 2023, 14 (03)
  • [25] Exploring Regional Reduction Pathways for Human Exposure to Fine Particulate Matter (PM2.5) Using a Traffic Assignment Model
    Bin Thaneya, Ahmad
    Horvath, Arpad
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (48) : 19649 - 19662
  • [26] Heavy metals and their source identification in particulate matter(PM2.5) in Isfahan City, Iran
    Mohsen Soleimani
    Nasibeh Amini
    Babak Sadeghian
    Dongsheng Wang
    Liping Fang
    Journal of Environmental Sciences, 2018, (10) : 166 - 175
  • [27] Analysis of PAHs Associated with Particulate Matter PM2.5 in Two Places at the City of Cuernavaca, Morelos, Mexico
    Saldarriaga-Norena, Hugo
    Lopez-Marquez, Rebecca
    Murillo-Tovar, Mario
    Hernandez-Mena, Leonel
    Ospina-Norena, Efren
    Sanchez-Salinas, Enrique
    Waliszewski, Stefan
    Montiel-Palma, Silvia
    ATMOSPHERE, 2015, 6 (09): : 1259 - 1270
  • [28] Bioaccessibility and exposure assessment of trace metals from urban airborne particulate matter (PM10 and PM2.5) in simulated digestive fluid
    Gao, Peng
    Guo, Huiyuan
    Zhang, Zhaohan
    Ou, Cuiyun
    Hang, Jian
    Fan, Qi
    He, Chuan
    Wu, Bing
    Feng, Yujie
    Xing, Baoshan
    ENVIRONMENTAL POLLUTION, 2018, 242 : 1669 - 1677
  • [29] Determinants of exposure to ultrafine particulate matter, black carbon, and PM2.5 in common travel modes in Istanbul
    Onat, Burcu
    Sahin, Ulku Alver
    Uzun, Burcu
    Akin, Ozcan
    Ozkaya, Fazilet
    Ayvaz, Coskun
    ATMOSPHERIC ENVIRONMENT, 2019, 206 : 258 - 270
  • [30] Monitoring of long-term personal exposure to fine particulate matter (PM2.5)