High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector

被引:2
|
作者
Chan, Lieza M. [1 ]
Courteau, Brandon J. [1 ]
Maker, Allison [1 ]
Wu, Mengyu [3 ,5 ]
Basanta, Benjamin [3 ,6 ]
Mehmood, Hev [1 ]
Bulkley, David [2 ]
Joyce, David [4 ]
Lee, Brian C. [4 ]
Mick, Stephen [4 ]
Czarnik, Cory [4 ]
Gulati, Sahil [4 ]
Lander, Gabriel C. [3 ]
Verba, Kliment A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Cellular & Mol Pharmacol, San Francisco, CA 94158 USA
[2] Univ Calif San Francisco, Dept Biochem & Biophys, San Francisco, CA 94158 USA
[3] Scripps Res, Dept Integrat Struct & Computat Biol, La Jolla, CA 92037 USA
[4] Gatan Inc, Pleasanton, CA USA
[5] Neomorph, San Diego, CA USA
[6] Arzeda, Seattle, WA USA
关键词
Single -particle cryo-EM; Direct detectors; Advances in microscope hardware; 100 keV imaging; Gatan Alpine; LKB1; complex; BEAM-INDUCED MOTION; CRYO-EM; RADIATION-DAMAGE; MICROSCOPY; VISUALIZATION; LIMITATIONS; VALIDATION; CONTRAST; TOOLS;
D O I
10.1016/j.jsb.2024.108108
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these energies, specifically a- 4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 & Aring; resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope fitted with a non-standard SP-Twin lens. We also achieved a- 3.2 & Aring; resolution reconstruction of a 115 kDa asymmetric protein complex, proving Alpine 's effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine 's capability for high-resolution data acquisition and screening on lower-end systems by obtaining- 3 & Aring; resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, bringing smaller sized particles within the scope of cryo-EM.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Development of a high-efficiency high-resolution imaging detector for 30-80 keV X-rays
    Olsen, U. L.
    Badel, X.
    Linnros, J.
    Di Michiel, M.
    Martin, T.
    Schmidt, S.
    Poulsen, H. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 52 - 55
  • [33] Dynamic and high-resolution live cell imaging by direct electron beam excitation
    Nawa, Yasunori
    Inami, Wataru
    Chiba, Akito
    Ono, Atsushi
    Miyakawa, Atsuo
    Kawata, Yoshimasa
    Lin, Sheng
    Terakawa, Susumu
    OPTICS EXPRESS, 2012, 20 (05): : 5629 - 5635
  • [34] DIRECT IMAGING OF SURFACE RECONSTRUCTIONS ON CDTE BY HIGH-RESOLUTION ELECTRON-MICROSCOPY
    LU, P
    SMITH, DJ
    PHYSICAL REVIEW LETTERS, 1987, 59 (19) : 2177 - 2179
  • [35] Denoising of high-resolution single-particle electron-microscopy density maps by their approximation using three-dimensional Gaussian functions
    Jonic, S.
    Vargas, J.
    Melero, R.
    Gomez-Blanco, J.
    Carazo, J. M.
    Sorzano, C. O. S.
    JOURNAL OF STRUCTURAL BIOLOGY, 2016, 194 (03) : 423 - 433
  • [36] High-resolution single-particle orientation refinement based on spectrally self-adapting common lines
    Elmlund, Dominika
    Elmlund, Hans
    JOURNAL OF STRUCTURAL BIOLOGY, 2009, 167 (01) : 83 - 94
  • [37] IceBreaker: Software for high-resolution single-particle cryo-EM with non-uniform ice
    Olek, Mateusz
    Cowtan, Kevin
    Webb, Donovan
    Chaban, Yuriy
    Zhang, Peijun
    STRUCTURE, 2022, 30 (04) : 522 - +
  • [38] Opportunities and Pitfalls of Fluorescent Labeling Methodologies for Extracellular Vesicle Profiling on High-Resolution Single-Particle Platforms
    Fortunato, Diogo
    Mladenovic, Danilo
    Criscuoli, Mattia
    Loria, Francesca
    Veiman, Kadi-Liis
    Zocco, Davide
    Koort, Kairi
    Zarovni, Natasa
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (19)
  • [39] SINGLE SIDE-BAND IMAGING IN HIGH-RESOLUTION ELECTRON-MICROSCOPY
    HOHENSTEIN, M
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1992, 54 (06): : 485 - 492
  • [40] Co-localization of cell surface receptors at high spatial resolution by single-particle fluorescence imaging
    Karakikes, I
    Barber, RE
    Morrison, IEG
    Fernández, N
    Cherry, RJ
    BIOCHEMICAL SOCIETY TRANSACTIONS, 2003, 31 : 1453 - 1455