High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector

被引:2
|
作者
Chan, Lieza M. [1 ]
Courteau, Brandon J. [1 ]
Maker, Allison [1 ]
Wu, Mengyu [3 ,5 ]
Basanta, Benjamin [3 ,6 ]
Mehmood, Hev [1 ]
Bulkley, David [2 ]
Joyce, David [4 ]
Lee, Brian C. [4 ]
Mick, Stephen [4 ]
Czarnik, Cory [4 ]
Gulati, Sahil [4 ]
Lander, Gabriel C. [3 ]
Verba, Kliment A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Cellular & Mol Pharmacol, San Francisco, CA 94158 USA
[2] Univ Calif San Francisco, Dept Biochem & Biophys, San Francisco, CA 94158 USA
[3] Scripps Res, Dept Integrat Struct & Computat Biol, La Jolla, CA 92037 USA
[4] Gatan Inc, Pleasanton, CA USA
[5] Neomorph, San Diego, CA USA
[6] Arzeda, Seattle, WA USA
关键词
Single -particle cryo-EM; Direct detectors; Advances in microscope hardware; 100 keV imaging; Gatan Alpine; LKB1; complex; BEAM-INDUCED MOTION; CRYO-EM; RADIATION-DAMAGE; MICROSCOPY; VISUALIZATION; LIMITATIONS; VALIDATION; CONTRAST; TOOLS;
D O I
10.1016/j.jsb.2024.108108
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these energies, specifically a- 4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 & Aring; resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope fitted with a non-standard SP-Twin lens. We also achieved a- 3.2 & Aring; resolution reconstruction of a 115 kDa asymmetric protein complex, proving Alpine 's effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine 's capability for high-resolution data acquisition and screening on lower-end systems by obtaining- 3 & Aring; resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, bringing smaller sized particles within the scope of cryo-EM.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] SINGLE-PARTICLE DETECTOR SYSTEM FOR HIGH-RESOLUTION TIME MEASUREMENTS
    BROCKHAUS, H
    GLASMACHERS, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 707 - 711
  • [2] Prospects and Limitations of High-Resolution Single-Particle Cryo-Electron Microscopy
    Chari, Ashwin
    Stark, Holger
    ANNUAL REVIEW OF BIOPHYSICS, 2023, 52 : 391 - 411
  • [3] Measurement of the resolution of the Timepix4 detector for 100 keV and 200 keV electrons for transmission electron microscopy
    Dimova, N.
    Plackett, R.
    Weatherill, D.
    Wood, D.
    O'Ryan, L.
    Crevatin, G.
    Barnard, J. S.
    Gallagher-Jones, M.
    Hynds, D.
    Goldsbrough, R.
    Shipsey, I.
    Bortoletto, D.
    Kirkland, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1075
  • [4] Method for immobilization of living and synthetic cells for high-resolution imaging and single-particle tracking
    Łukasz Syga
    Dian Spakman
    Christiaan M. Punter
    Bert Poolman
    Scientific Reports, 8
  • [5] Method for immobilization of living and synthetic cells for high-resolution imaging and single-particle tracking
    Syga, Lukasz
    Spakman, Dian
    Punter, Christiaan M.
    Poolman, Bert
    SCIENTIFIC REPORTS, 2018, 8
  • [6] High-resolution cryo-EM using a common LaB6 120-keV electron microscope equipped with a sub-200-keV direct electron detector
    Venugopal, Hariprasad
    Mobbs, Jesse
    Taveneau, Cyntia
    Fox, Daniel R.
    Vuckovic, Ziva
    Gulati, Sahil
    Knott, Gavin
    Grinter, Rhys
    Thal, David
    Mick, Stephen
    Czarnik, Cory
    Ramm, Georg
    SCIENCE ADVANCES, 2025, 11 (01):
  • [7] CORRECTING FOR THE EWALD SPHERE IN HIGH-RESOLUTION SINGLE-PARTICLE RECONSTRUCTIONS
    Leong, Peter A.
    Yu, Xuekui
    Zhou, Z. Hong
    Jensen, Grant J.
    METHODS IN ENZYMOLOGY, VOL 482: CRYO-EM, PART B: 3-D RECONSTRUCTION, 2010, 482 : 369 - 380
  • [8] EMAN: Semiautomated software for high-resolution single-particle reconstructions
    Ludtke, SJ
    Baldwin, PR
    Chiu, W
    JOURNAL OF STRUCTURAL BIOLOGY, 1999, 128 (01) : 82 - 97
  • [9] HIGH-RESOLUTION IMAGING OF SILICON (111) USING A 100 KEV STEM
    XU, PR
    KIRKLAND, EJ
    SILCOX, J
    KEYSE, R
    ULTRAMICROSCOPY, 1990, 32 (02) : 93 - 102
  • [10] Unsupervised particle sorting for high-resolution single-particle cryo-EM
    Zhou, Ye
    Moscovich, Amit
    Bendory, Tamir
    Bartesaghi, Alberto
    INVERSE PROBLEMS, 2020, 36 (04)