A polarization-improved dual-beam spin-exchange relaxation-free magnetometer with reflection-assisted pumping

被引:2
作者
Huang, Binyue [1 ,7 ]
Liu, Ying [1 ,2 ,3 ,4 ,5 ]
Li, Renjie [1 ,4 ]
Li, Jiajie [1 ,4 ]
Tang, Junjian [1 ,4 ,8 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Beihang Univ, Inst Large scale Sci Facil, Beijing 100191, Peoples R China
[3] Beihang Univ, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[5] Natl Inst Extremely Weak Magnet Field Infrastruct, Hangzhou 310051, Peoples R China
[6] Hefei Natl Lab, Hefei 230088, Peoples R China
[7] Beihang Univ, Shen Yuan Honors Coll, Beijing 100191, Peoples R China
[8] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Reflective atomic magnetometer; Double-pass pumping; Optical polarization; Spin-exchange relaxation-free; High sensitivity; ATOMIC MAGNETOMETER;
D O I
10.1016/j.sna.2024.115523
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The highly sensitive SERF magnetometers hold exciting prospects for magnetocardiography and magnetoencephalography, and the accuracy of medical measurements depends largely on the performance of the magnetometers. A double -pass configuration is used to obtain uniform polarization and constructed by adding a mirror to retro -reflect the pump light. The transmission model of the reflected light which takes the effect of forward light into account is proposed, and the improved polarization is experimentally verified. The essential operation parameters of the magnetometer are optimized. The theoretical framework is established outlining the relationship between pump power, probe frequency, and signal response, and the optimal values for these parameters are experimentally determined. With the appropriate selection of probe power and operating temperature, the double -pass configuration achieves a sensitivity of 5.81 fT/Hz 1/2 , a bandwidth of 110 Hz, and represents a 17% improvement in stability compared to the single -pass configuration. The optimized magnetometer exhibits reduced susceptibility to laser conditions and enhanced stability, attributed to the reflection -assisted polarization improvement and better uniformity. This configuration efficiently utilizes the pumping laser, and its miniaturization offers significant benefits for magnetoencephalography and other biomagnetic measurements.
引用
收藏
页数:8
相关论文
共 45 条
  • [1] Measurement of the Permanent Electric Dipole Moment of the Neutron
    Abel, C.
    Afach, S.
    Ayres, N. J.
    Baker, C. A.
    Ban, G.
    Bison, G.
    Bodek, K.
    Bondar, V.
    Burghoff, M.
    Chanel, E.
    Chowdhuri, Z.
    Chiu, P. -J.
    Clement, B.
    Crawford, C. B.
    Daum, M.
    Emmenegger, S.
    Ferraris-Bouchez, L.
    Fertl, M.
    Flaux, P.
    Franke, B.
    Fratangelo, A.
    Geltenbort, P.
    Green, K.
    Griffith, W. C.
    van der Grinten, M.
    Grujic, Z. D.
    Harris, P. G.
    Hayen, L.
    Heil, W.
    Henneck, R.
    Helaine, V.
    Hild, N.
    Hodge, Z.
    Horras, M.
    Iaydjiev, P.
    Ivanov, S. N.
    Kasprzak, M.
    Kermaidic, Y.
    Kirch, K.
    Knecht, A.
    Knowles, P.
    Koch, H. -C.
    Koss, P. A.
    Komposch, S.
    Kozela, A.
    Kraft, A.
    Krempel, J.
    Kuzniak, M.
    Lauss, B.
    Lefort, T.
    [J]. PHYSICAL REVIEW LETTERS, 2020, 124 (08)
  • [2] High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation
    Allred, JC
    Lyman, RN
    Kornack, TW
    Romalis, MV
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (13) : 130801 - 130801
  • [3] Nonlinear analysis of brain activity in magnetic influenced Parkinson patients
    Anninos, PA
    Adamopoulos, AV
    Kotini, A
    Tsagas, N
    [J]. BRAIN TOPOGRAPHY, 2000, 13 (02) : 135 - 144
  • [4] Theory of spin-exchange optical pumping of 3He and 129Xe
    Appelt, S
    Baranga, AB
    Erickson, CJ
    Romalis, MV
    Young, AR
    Happer, W
    [J]. PHYSICAL REVIEW A, 1998, 58 (02): : 1412 - 1439
  • [5] SQUID-Based Microwave Cavity Search for Dark-Matter Axions
    Asztalos, S. J.
    Carosi, G.
    Hagmann, C.
    Kinion, D.
    van Bibber, K.
    Hotz, M.
    Rosenberg, L. J.
    Rybka, G.
    Hoskins, J.
    Hwang, J.
    Sikivie, P.
    Tanner, D. B.
    Bradley, R.
    Clarke, J.
    [J]. PHYSICAL REVIEW LETTERS, 2010, 104 (04)
  • [6] Magnetic Source Imaging Using a Pulsed Optically Pumped Magnetometer Array
    Borna, Amir
    Carter, Tony R.
    DeRego, Paul
    James, Conrad D.
    Schwindt, Peter D. D.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (02) : 493 - 501
  • [7] On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
    Boto, Elena
    Bowtell, Richard
    Kruger, Peter
    Fromhold, T. Mark
    Morris, Peter G.
    Meyer, Sofie S.
    Barnes, Gareth R.
    Brookes, Matthew J.
    [J]. PLOS ONE, 2016, 11 (08):
  • [8] Tutorial: Basic principles, limits of detection, and pitfalls of highly sensitive SQUID magnetometry for nanomagnetism and spintronics
    Buchner, M.
    Hoefler, K.
    Henne, B.
    Ney, V.
    Ney, A.
    [J]. JOURNAL OF APPLIED PHYSICS, 2018, 124 (16)
  • [9] Optical magnetometry
    Budker, Dmitry
    Romalis, Michael
    [J]. NATURE PHYSICS, 2007, 3 (04) : 227 - 234
  • [10] Signal-enhanced spin-exchange relaxation-free atomic magnetometer
    Cao, Li
    Tang, Junjian
    Zhang, Yaohua
    Yuan, Ziqi
    Li, Jiajie
    Zhai, Yueyang
    Liu, Ying
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2023, 353