DNA typing of cyanoacrylate fumed latent fingerprints using GlobalFiler™ and ForenSeq™ Signature Prep kits

被引:0
作者
Bodnar, Sara R. [1 ]
Smith, Coral [1 ]
Alsharji, Alekhlas A. [1 ]
Moroose, Tina [1 ]
Venter, Casper [1 ]
Iyengar, Arati [1 ]
机构
[1] West Virginia Univ, Dept Forens & Invest Sci, Morgantown, WV 26505 USA
关键词
CE; cyanoacrylate fuming; fingerprints; forensic genetics; low template DNA; MPS; FORENSIC GENOMICS SYSTEM; TOUCH DNA; DEVELOPMENTAL VALIDATION; STR; FINGERMARKS; PERFORMANCE; RECOVERY; CHEMISTRY; TIME;
D O I
10.1111/1556-4029.15566
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
DNA typing of latent fingerprints is highly desirable to increase chances of individualization. We recovered DNA from Cyanoacrylate (CA) fumed fingerprints and used both GlobalFiler (TM) and ForenSeq (TM) DNA Signature Prep kits for DNA typing. For GlobalFiler (TM), samples were processed using a protocol modified for Low Template (LT)-DNA samples (half-volume reactions, 30 cycles) while for ForenSeq (TM) DNA Signature Prep, samples were processed using a standard protocol and fluorometer-based library quantitation. We evaluated genotyping success and quality of profiles in terms of completeness, Peak Height Ratio/Allele Coverage Ratio, presence of PCR artifacts and drop-in alleles. With GlobalFiler (TM), average autosomal STR (aSTR) profile completeness was 44.4% with 2-20 pg, 54.3% with 22-60 pg, and 95% with 64-250 pg DNA input. CODIS uploadable profiles were obtained in 2/10, 3/11, and 11/12 samples in these ranges. With ForenSeq (TM) DNA Signature Prep, average aSTR profile completeness was 19.7% with 1-20 pg and 45.2% with 22-47 pg but increased to 78.3% with 68-122 pg and 86.7% with 618-1000 pg DNA input. Uploadable profiles were obtained in 0/12, 4/11, 4/7, and 3/3 samples for these ranges. Results show very high sensitivity using both kits. Half-volume reactions and 30 cycles had minimal negative effect on Globalfiler (TM) profile quality, providing support for wider use after validation experiments to routinely improve results from LT samples. A standard protocol for the ForenSeq (TM) DNA Signature Prep kit was also highly successful with LT DNA obtained from CA-fumed fingerprints with additional information from isometric STR alleles and other markers.
引用
收藏
页码:1706 / 1717
页数:12
相关论文
共 72 条
[1]   Systematic assessment of the performance of illumina's MiSeq FGx™ forensic genomics system [J].
Almalki, Nouran ;
Chow, Hoi Yan ;
Sharma, Vishakha ;
Hart, Katie ;
Siegel, Donald ;
Wurmbach, Elisa .
ELECTROPHORESIS, 2017, 38 (06) :846-854
[2]   Internal validation of GlobalFiler™ kit using reduced reaction volume [J].
Almohammed, E. ;
Hadi, S. .
FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2019, 7 (01) :878-883
[3]   Internal validation of reduced PCR reaction volume of the Qiagen Investigator® Argus X-12 QS Kit from blood samples on FTA cards [J].
Alwi, Aedrianee Reeza ;
Mahat, Naji Arafat ;
Mohd Salleh, Faezah ;
Ishar, Seri Mirianti ;
Kamaluddin, Mohammad Rahim ;
Rashid, Mohd Radzniwan A. .
JOURNAL OF FORENSIC SCIENCES, 2023, 68 (06) :2103-2115
[4]   Effects of Cyanoacrylate Fuming, Time After Recovery, and Location of Biological Material on the Recovery and Analysis of DNA from Post-Blast Pipe Bomb Fragments [J].
Bille, Todd W. ;
Cromartie, Carter ;
Farr, Matthew .
JOURNAL OF FORENSIC SCIENCES, 2009, 54 (05) :1059-1067
[5]  
Brito P, 2017, FORENS SCI INT-GEN S, V6, pE362, DOI 10.1016/j.fsigss.2017.09.109
[6]   The Extraction and Recovery Efficiency of Pure DNA for Different Types of Swabs [J].
Bruijns, Brigitte B. ;
Tiggelaar, Roald M. ;
Gardeniers, Han .
JOURNAL OF FORENSIC SCIENCES, 2018, 63 (05) :1492-1499
[7]   The origin of unknown source DNA from touched objects [J].
Buckingham, Alycia K. ;
Harvey, Michelle L. ;
van Oorschot, Roland A. H. .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2016, 25 :26-33
[8]   Exploration of cell-free DNA (cfDNA) recovery for touch deposits [J].
Burrill, Julia ;
Kombara, Anju ;
Daniel, Barbara ;
Frascione, Nunzianda .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2021, 51
[9]   Optimizing direct amplification of forensic commercial kits for STR determination [J].
Caputo, M. ;
Bobillo, M. C. ;
Sala, A. ;
Corach, D. .
JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2017, 47 :17-23
[10]   Quantifying DNA loss in laboratory-created latent prints due to fingerprint processing [J].
Carlin, Madison ;
Nickel, Ryan ;
Halstead, Krisha ;
Viray, Joy ;
Hall, Ashley ;
Ehrlich, Allison .
FORENSIC SCIENCE INTERNATIONAL, 2023, 344