Measurements of 131I activity in thyroid of workers at the place of radioiodine therapy in 38 hospitals in China

被引:1
作者
Li, Xiao-Liang [1 ]
Zhang, Jian-Feng [1 ]
Wang, Shuo [1 ]
Liu, Jian-Xiang [1 ]
Tuo, Fei [1 ]
Sun, Quan-Fu [1 ,2 ]
机构
[1] Natl Inst Radiol Protect, Chinese Ctr Dis Control & Prevent, Key Lab Radiol Protect & Nucl Emergency, Beijing 100088, Peoples R China
[2] Natl Inst Radiol Protect, Chinese Ctr Dis Control & Prevent, 2 Xinkang St, Beijing 100088, Peoples R China
关键词
I-131; thyroid; nuclear medicine; internal monitoring;
D O I
10.1093/jrr/rrae036
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To investigate the levels of I-131 activity in thyroid of workers at the place of radioiodine therapy and their main influential factors in China, 341 workers at 38 hospitals performing radioiodine therapy procedure in five provinces were recruited to be measured in 2021. A hand-held gamma spectrometer with NaI(Tl) probe was plastered to the thyroids and thighs of the subjects during the measurement, and each measurement time was 120 s. The internal exposure dose was calculated, and the committed effective dose was estimated. In 86 (25.22%) of the 341 examined workers, I-131 thyroid activity was above minimum detectable activity (MDA, 26.6 Bq). The maximum activity was 4.9 x 10(3 )Bq. The detection results above MDA were at 22 (57.89%) different hospitals. The detectable rate for private hospitals (4.8%) was significantly lower than that for public hospitals (26.6%), P < 0.05. The detectable rate for hospitals in provincial capital cities (15.4%) was significantly lower than in nonprovincial capital cities (41.7%), P < 0.001. The detectable rate for hospitals engaged in I-131 therapy for thyroid cancer (31.2%) was significantly higher than only for hyperthyroidism (10.3%), P < 0.001. A total of 32 subjects' committed effective dose might exceed 1 mSv. Results indicated the I-131 activity in the thyroid of workers at the place of radioiodine varied considerably in China, and mainly related to ownership, location and therapy program of the hospitals.
引用
收藏
页码:459 / 466
页数:8
相关论文
共 20 条
  • [1] American National Standards Institute Health Physics Society, 2011, ANSI/HPS N13.302011. Performance Criteria for Radiobioassay
  • [2] American National Standards Institute Health Physics Society, 2014, ANSI/HPS Standard N13.44-2014. Thyroid Phantom Used in Occupational Monitoring
  • [3] [Anonymous], 1997, Individual monitoring for internal exposure of workers
  • [4] [Anonymous], 2004, QUANTIFYING UNCERTAI
  • [5] [Anonymous], National Health Family Planning Commission of the People's Republic of China
  • [6] Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital
    Brudecki, K.
    Kowalska, A.
    Zagrodzki, P.
    Szczodry, A.
    Mroz, T.
    Janowski, P.
    Mietelski, J. W.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2017, 56 (01) : 19 - 26
  • [7] 王松, 2020, [中国实用外科杂志, Chinese Journal of Practical Surgery], V40, P747
  • [8] NATIONAL DOSE REGISTRY AND TRENDS OF OCCUPATIONAL EXPOSURE TO IONISING RADIATION IN CHINA (2009-2018)
    Deng, Jun
    Fan, Shengnan
    Wang, Tuo
    Li, Mengxue
    Guo, Wen
    Sun, Quanfu
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 376 - 381
  • [9] Trends and Distribution Analysis of Occupational Exposure From Medical Practices in China (2010-2016)
    Deng, Jun
    Fan, Shengnan
    Wang, Tuo
    Hao, Shuxia
    Liu, Xiaohui
    Guo, Wen
    Sun, Quanfu
    [J]. HEALTH PHYSICS, 2019, 117 (06): : 656 - 660
  • [10] [范胜男 Fan Shengnan], 2021, [中华放射医学与防护杂志, Chinese Journal of Radiological Medicine and Protection], V41, P85