Low-background fluorescent biosensor based on graphene oxide and aptamer biorecognition for sensitive detection of kanamycin

被引:14
作者
Cui, Wanling [1 ,3 ]
Hu, Churuo [1 ,3 ]
Zhu, Rui [2 ]
Qiu, Dewen [1 ,3 ]
Gong, Ruihong [2 ]
Wang, Rui [1 ,3 ]
Li, Qiang [1 ,3 ]
Yan, Tingting [1 ,3 ]
Li, Chonghui [1 ,3 ]
Qiao, Mei [4 ]
Xu, Shicai [1 ,3 ]
机构
[1] Dezhou Univ, Inst Biophys, Shandong Key Lab Biophys, Dezhou 253023, Peoples R China
[2] Zouping Peoples Hosp, Zibo 256200, Peoples R China
[3] Dezhou Univ, Engn Lab Swine Herd Hlth Big Data & Intelligent Mo, Dezhou 253023, Peoples R China
[4] Dezhou Univ, Coll Phys & Elect Informat, Dezhou 253023, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluorescent biosensor; Kanamycin; Aptamer; Graphene oxide; Low; -background; CAPILLARY-ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; DERIVATIZATION; MACHINE;
D O I
10.1016/j.jfca.2024.106261
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The detection of kanamycin has attracted extensive attention in the field of food safety. A label-free, lowbackground fluorescent biosensor was successfully constructed based on graphene oxide and aptamer biorecognition in this paper for kanamycin detection in milk samples. In this biosensor, the integrated probe with the aptamer sequence of kanamycin and the G-rich sequence was designed. The aptamer sequence of kanamycin was used as the recognition part, the G-quadruplex/N-methyl mesoporphyrin IX (NMM) complex as the fluorescent probe, and graphene oxide as the fluorescent quencher. Initially, the integrated probe could be adsorbed on the graphene oxide surface through 7C-7C stacking interactions, while the fluorescence of NMM could be efficiently quenched because of the resonance energy transfer between NMM and graphene oxide, which was beneficial to the low background signal of the system. During the detection process, the aptamer sequence preferred to bind to kanamycin, forming aptamer-kanamycin complex. At the same time, the G-rich sequence folded into G-quadruplex structure that specifically bound to NMM under the action of K+, forming G-quadruplex/NMM complex. Under the synergistic effects of the two complexes, the integrated probe with aptamerkanamycin complex and G-quadruplex/NMM complex was released from the graphene oxide surface due to the steric hindrance effect, restoring the strong fluorescence signal. By combining graphene oxide and Gquadruplex/NMM complex, the fluorescent biosensor could effectively achieve label-free and low-background detection of kanamycin. The linear calibration curve was in the range of 1-400 nM with a detection limit of 0.60 nM for kanamycin. It was successfully applied to analyze raw milk samples (spiked kanamycin) with recoveries of 98.33-101.25 % and also exhibited high selectivity for kanamycin. The experimental data showed that the biosensor was a potentially powerful tool for monitoring food safety.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Graphene oxide-based fluorescent sensor for sensitive turn-on detection of sinapine [J].
Xiang, Xia ;
Han, Ling ;
Zhang, Zhen ;
Huang, Fenghong .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 174 :75-79
[42]   A highly sensitive of electrochemical biosensor based on new aptamer sequence for 17α-ethinylestradiol detection in water [J].
Rozi, Normazida ;
Abu Hanifah, Sharina ;
Hassan, Riyadh Abdulmalek ;
Karim, Nurul Huda Abdul ;
Ikeda, Masato ;
Mansor, Nurul Nasuha ;
Mun, Tang Kok ;
Arputheraj, Teffanie A. P. .
MICROCHEMICAL JOURNAL, 2024, 205
[43]   Ultrahigh sensitive graphene oxide/conducting polymer composite based biosensor for cholesterol and bilirubin detection [J].
Kumar A. ;
Gupta G.H. ;
Singh G. ;
More N. ;
M K. ;
Sharma A. ;
Jawade D. ;
Balu A. ;
Kapusetti G. .
Biosensors and Bioelectronics: X, 2023, 13
[44]   Aptamer-Based Fluorescent Assay for Sensitive Detection of Cardiac Troponin Ⅰ [J].
Yu Li ;
Yuanzhan Yang ;
Xuefei Lü ;
Yulin Deng .
JournalofBeijingInstituteofTechnology, 2020, 29 (01) :45-51
[45]   An ultrasensitive label-free biosensor based on aptamer functionalized two-dimensional photonic crystal for kanamycin detection in milk [J].
Li, Xiaoxuan ;
Jia, Mingdi ;
Yu, Licheng ;
Li, Yijun ;
He, Xiwen ;
Chen, Langxing ;
Zhang, Yukui .
FOOD CHEMISTRY, 2023, 402
[46]   A Split G-Quadruplex and Graphene Oxide-Based Low-Background Platform for Fluorescence Authentication of Pseudostellaria heterophylla [J].
Zheng, Zhenzhu ;
Hu, Juan ;
He, Zhaodong .
SENSORS, 2014, 14 (12) :22971-22981
[47]   Aptamer-based biosensor for sensitive PDGF detection using diamond transistor [J].
Ruslinda, A. Rahim ;
Tajima, Shinya ;
Ishii, Yoko ;
Ishiyama, Yuichiro ;
Edgington, Robert ;
Kawarada, Hiroshi .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) :1599-1604
[48]   DNA aptamer-based sensitive electrochemical biosensor for NAD (H) detection [J].
Guo, Wenfei ;
Wang, Haiyuan ;
Wang, Zhaoyang ;
Wu, Fandi ;
He, Yao ;
Liu, Yuan ;
Deng, Yan ;
Bing, Tao ;
Qiu, Liping ;
Tan, Weihong .
BIOSENSORS & BIOELECTRONICS, 2025, 271
[49]   Highly Sensitive Fluorescent Biosensor Based on Acetylcholinesterase and Carbon Dots-Graphene Oxide Quenching Test for Analytical and Commercial Organophosphate Pesticide Detection [J].
Gaviria, Maria I. ;
Barrientos, Kaory ;
Arango, Juan Pablo ;
Cano, Juan B. ;
Penuela, Gustavo A. .
FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 10
[50]   A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform [J].
Liu, Dongkui ;
Lu, Xing ;
Yang, Yiwen ;
Zhai, Yunyun ;
Zhang, Jian ;
Li, Lei .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (18) :4285-4291