Shear bond strength of ultraviolet-polymerized resin to 3D-printed denture materials: Effects of post-polymerization, surface treatments, and thermocycling

被引:0
作者
Tanaka, Ami [1 ]
Kawaguchi, Tomohiro [1 ,2 ,3 ]
Ito, Ayaka [1 ]
Isshi, Kota [4 ]
Hamanaka, Ippei [1 ]
Tsuzuki, Takashi [1 ]
机构
[1] Fukuoka Dent Coll, Dept Oral Rehabil, Div Removable Prosthodont, 2-15-1 Tamura Sawara Ku, Fukuoka 8140193, Japan
[2] Univ Turku, Inst Dent, Dept Biomat Sci, Turku, Finland
[3] Univ Turku, Inst Dent, Turku Clin Biomat Ctr TCBC, Turku, Finland
[4] Fukuoka Dent Coll Med & Dent Hosp, Cent Dent Lab, Fukuoka, Japan
基金
日本学术振兴会;
关键词
3D printing; CAD-CAM; digital denture; bond strength; denture base; ARTIFICIAL TEETH; TECHNOLOGY;
D O I
10.2186/jpr.JPR_D_23_00321
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study is to compare the shear bond strength of ultraviolet (UV) -polymerized resin to 3Dprinted denture materials, both with and without post -polymerization. Moreover, the effects of surface treatment and thermocycling on shear bond strength after post -polymerization were investigated. Methods: Cylindrical 3D -printed denture bases and teeth specimens were prepared. The specimens are subjected to two tests. For Test 1, the specimens were bonded without any surface treatment or thermal stress for comparison with and without post -polymerization. In Test 2, specimens underwent five surface treatments: untreated (CON), ethyl acetate (EA), airborne particle abrasion (APA) with 50 mu m (50-APA) and 110 mu m alumina (110-APA), and tribochemical silica coating (TSC). A UV -polymerized resin was used for bonding. Half of the Test 2 specimens were thermocycled for 10,000 cycles. Shear bond strength was measured and analyzed using Kruskal-Wallis and Steel-Dwass tests (n = 8). Results: In Test 1, post -polymerization significantly reduced shear bond strength of both 3D -printed denture materials (P < 0.05). No notable difference was observed between the denture teeth and the bases (P > 0.05). In Test 2, before thermocycling, the CON and EA groups exhibited low bond strengths, while the 50-APA, 110-APA, and TSC groups exhibited higher bond strengths. Thermocycling did not reduce bond strength in the latter groups, but significantly reduced bond strength in the EA group (P < 0.001). Conclusions: Post -polymerization can significantly reduce the shear bond strength of 3D -printed denture materials. Surface treatments, particularly APA and TSC, maintained bond strength even after thermocycling.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 47 条
  • [21] CAD/CAM FABRICATED COMPLETE DENTURES: CONCEPTS AND CLINICAL METHODS OF OBTAINING REQUIRED MORPHOLOGICAL DATA
    Goodacre, Charles J.
    Garbacea, Antoanela
    Naylor, W. Patrick
    Daher, Tony
    Marchack, Christopher B.
    Lowry, Jean
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (01) : 34 - 46
  • [22] Water sorption, water solubility, degree of conversion, elastic indentation modulus, edge chipping resistance and flexural strength of 3D-printed denture base resins
    Greil, Veronika
    Mayinger, Felicitas
    Reymus, Marcel
    Stawarczyk, Bogna
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 137
  • [23] Effect of printing direction on stress distortion of three-dimensional printed dentures using stereolithography technology
    Hada, Tamaki
    Kanazawa, Manabu
    Iwaki, Maiko
    Arakida, Toshio
    Minakuchi, Shunsuke
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [24] Bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins
    Hamanaka, Ippei
    Shimizu, Hiroshi
    Takahashi, Yutaka
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (01) : 67 - 72
  • [25] Shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins
    Hamanaka, Ippei
    Shimizu, Hiroshi
    Takahashi, Yutaka
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1250 - 1254
  • [26] In Vitro Analysis of Shear Stress: CAD Milled vs Printed Denture Base Resins with Bonded Denture Tooth
    Kane, Brittany
    Shah, Kumar C.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 29 - 37
  • [27] Effects of layer thickness and build angle on the microbial adhesion of denture base polymers manufactured by digital light processing
    Li, Ping
    Fernandez, Pablo Kraemer
    Spintzyk, Sebastian
    Schmidt, Franziska
    Yassine, Jamila
    Beuer, Florian
    Unkovskiy, Alexey
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 562 - 567
  • [28] Postpolymerization of a 3D-printed denture base polymer: Impact of post-curing methods on surface characteristics, flexural strength, and cytotoxicity
    Li, Ping
    Lambart, Anna-Lena
    Stawarczyk, Bogna
    Reymus, Marcel
    Spintzyk, Sebastian
    [J]. JOURNAL OF DENTISTRY, 2021, 115
  • [29] Repairability of a 3D printed denture base polymer: Effects of surface treatment and artificial aging on the shear bond strength
    Li, Ping
    Kraemer-Fernandez, Pablo
    Klink, Andrea
    Xu, Yichen
    Spintzyk, Sebastian
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 114
  • [30] Maeda Y, 1994, Int J Prosthodont, V7, P17