Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract

被引:0
作者
Ke, Xixuan [1 ]
Li, Cuilian [1 ]
Lin, Liyu [1 ]
Huang, Yuqiang [1 ]
Xia, Honghe [1 ]
Jin, Chuang [1 ]
Shi, Tingkun [1 ]
Zhang, Qi [1 ]
Liao, Xulong [1 ]
Chen, Haoyu [1 ]
机构
[1] Shantou Univ & Chinese Univ Hong Kong, Joint Shantou Int Eye Ctr, North Dongxia Rd, Shantou 515041, Guangdong, Peoples R China
关键词
Ultrasonography; Traumatic cataract; Posterior capsule rupture; 20-MHZ ULTRASOUND PROBE;
D O I
10.1007/s00417-024-06523-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo investigate the performance of 10 MHz ultrasonography in detecting posterior lens capsule defects before traumatic cataract surgery.MethodsThis retrospective analysis includes patients with traumatic cataracts who underwent cataract surgery. Preoperative 10 MHz ultrasonography was performed to evaluate whether the posterior lens capsule was defective or intact, and the results were compared to the intraoperative findings. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa were calculated.ResultsThe study included 140 eyes of 140 patients. There were 68 eyes with closed-globe injuries and 72 eyes with open-globe injuries. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa of 10 MHz ultrasonography was 86.76%, 90.28%, 89.39%, 87.84%, 88.57% and 0.771, respectively. The accuracy was 86.11% and 91.18% in open-globe and closed-globe injury groups, respectively.ConclusionThe accuracy of 10 MHz ultrasonography in evaluating the posterior lens capsule in traumatic cataracts is high. Preoperative 10 MHz ultrasonography would help to make an appropriate surgical plan.
引用
收藏
页码:3629 / 3634
页数:6
相关论文
共 12 条
  • [1] Posterior capsule rupture following closed globe injury: Scheimpflug imaging, pathogenesis, and management
    Grewal, D. S.
    Jain, R.
    Brar, G. S.
    Grewal, S. P. S.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (03) : 453 - 455
  • [2] A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit
    Hewick, SA
    Fairhead, AC
    Culy, JC
    Atta, HR
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) : 551 - 555
  • [3] Milcu Adina-Iuliana, 2022, Rom J Ophthalmol, V66, P132, DOI 10.22336/rjo.2022.26
  • [4] Negrel A D, 1998, Ophthalmic Epidemiol, V5, P143, DOI 10.1076/opep.5.3.143.8364
  • [5] Visualization of posterior lens capsule integrity by 20-MHz ultrasound probe in ocular trauma
    Nguyen, TN
    Mansour, M
    Deschenes, J
    Lindley, S
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) : 754 - 755
  • [6] The Evaluation of Patients with Traumatic Cataracts by Ultrasound Technologies
    Perry, Lynn J. Poole
    [J]. SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 121 - 124
  • [7] Role of Scheimpflug imaging for assessment of posterior lens capsule in pediatric traumatic cataract
    Sen, Pradhnya
    Kumar, Naveen
    Mohan, Amit
    Shah, Chintan
    Jain, Elesh
    Sen, Alok
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (12) : 3520 - +
  • [8] Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract
    Tabatabaei, Ali
    Hasanlou, Narges
    Kheirkhah, Ahmad
    Mansouri, Mohammadreza
    Faghihi, Houshang
    Jafari, Hajar
    Arefzadeh, Alireza
    Moghimi, Sasan
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) : 1092 - 1096
  • [9] Evaluation of Posterior Lens Capsule by 20-MHz Ultrasound Probe in Traumatic Cataract
    Tabatabaei, Au
    Kiarudi, Mohammad Yaser
    Ghassemi, Fariba
    Moghimi, Sasan
    Mansouri, Mohammadreza
    Mirshahi, Ahmad
    Kheirkhah, Ahmad
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (01) : 51 - 54
  • [10] Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract
    Tabatabaei, Seyed Ali
    Soleimani, Mohammad
    Etesali, Hamed
    Naderan, Morteza
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 55 - 58